|
Tender For Provision Of Civil Works For Asr And Mssr Radars At Ins Parundu Under Ge Tirunelveli 81458 /E8; 1 GENERAL SUMMARY ( PHASE-I)NOTE: Schedule ‘A’ Part - I to XII are prepriced by MES under Ser No. 2.00to 13.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only. 2 Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES ” as listed in Schedule ‘A’ Part - I , 3 Lumpsum price worked out by the tenderer for SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/ EXCAVATION as listed in Schedule ‘A’ Part-II 4 Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III 5 Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV 6 Lumpsum price worked out by the tenderer for ROAD/PATH/HARD STANDING/CULVERT as listed in Schedule ‘A’ Part-V 7 Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI 8 Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII 9 Lumpsum price worked out by the tenderer for FENCING, GATE, & COMPOUND WALL as listed in Schedule ‘A’ Part-VIII 10 Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX 11 Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-X 12 Lumpsum price worked out by the tenderer for DG SET as listed in Schedule ‘A’ Part-XI 13 Lumpsum price worked out by the tenderer for AVIATION OBSTRUCTION LIGHT as listed in Schedule ‘A’ Part-XII 14 SCHEDULE A PART - XIIIMISCELLANEOUS ITEMSNOTE:Schedule ‘A’ Part - XIII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-7. 15 Material and labour for point wiring with two in number single core (for phase & neutral) and one in number (for earthing) single core 1100 V grade, FRLSH , PVC insulated unsheathed multi-stranded copper conductor cables of size 1.5 Sq mmincluding rigid PVC conduit and conduit accessories , metal terminal box concealed in wall and making good to disturbed surfaces in wall/ceiling wherever required along with 3 mm hylam sheet cover fixed overmetal boxesall as specified and directed for the following :- 16 (a)One light point , controlled by one switch complete 17 (b)One fan point, controlled by one switch complete 18 (c)One 3 pin 5 Amps switch socket combination on independent board 19 (d) One 3 pin 5 Amps switch socket combination on the same board with other switches, 20 (e) One light point controlled by two Nosof two way switches. 21 All as per above item No.15 but Point wiring with FRLS-H4.0 Sqmm single core PVC sheathed copper conductor cable, with PVC conduit for 3 pin socket outlet 15 amps, independent, completeall as specified and directed 22 Supply and fix for Wiring for Circuit / Submain Wiring of size 2 runs of 1.5 sq.mm along with earth wire of size 1 run of1.5 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 20 mm dia complete all as specified and as directed 23 Supply and fix for Wiring for Circuit / Submain Wiring of size 2 runs of 2.5 sq.mm along with earth wire of size 1 run of2.5 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 20 mm dia complete all as specified and as directed 24 Supply and fix for Wiring for Circuit / Submain Wiring of size 2 runs of 4.0 sq.mm along with earth wire of size 1 run of4.0 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 25 mm dia complete all as specified and as directed 25 Supply and fix sheet metal enclosure powder coated double door for Distribution Board,VTPN 4 way DBsuitable forMCCB Incomer IP 43 , IK 08 ,provided with insulated vertical phase bus-bars ,neutral bar/s with shroud/s ,earth bar/s , sticking saddles ,cement spill protector ,color-coded interconnecting wire set ,cable ties , blanking plates and circuit identification labels. complete all as specified and as directed. 26 Supply and fix pole mounting type FRP cable looping box of size 155 x 210 x 92mm, IP66 , with connector / terminal for connecting cable,with 40 x 6mm flat iron for fixing in street light pole,including Double Compression Weather Proof& flame proofBrass Cable Glands all as specified and as directed. 27 S & F double wall corrugated pipes 200 mm (OD)/175 mm (ID) pipes DCWPE (SN8) pipes laid on trenches etc complete all as specified and as directed. 28 Supply and fixing Septic tanksLLDPE type (25 user) of size1.54 m Dia and 1.65 m heightincluding vent pipe, cowl including conneted workto complete the entire work complete all as specified and as directed. 29 M & L Valve chamber of internal size 600mm X 600mm X 450mm (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge. 30 Supply,testing and laying of XLPE insulated, screened, PVC bedded,galvanised steel strip, electric power cables (heavyduty) with aluminium conductor, 22000 volts Earthed, 3 Core grade cross sectional area 185 sq. mm complete all as specified and as directed. 31 Material and Labour charges for supply and make end termination ofHeat Shrinkable Indoor End Termnation Kit 22 kV , suitable for XLPE Alumium cable of cross sectional area185 Sqmmcomplete all as specified and as directed 32 Supply, installation, testing and comissioning of copper wound transformer step down, 250 KVA outdoor ONAN type, Level-2 complete with standard fittings of tranformer, HT side 22KV and LT side 433 Volts, 3 Phase, 50 HZ , with 07 POSITION OFF circuit Tap Changer, tapping range ± 7 % in steps of 2.5 % each with vector group DYn-11with oil immersed complete with first filling of IS:335 ISI marked filtered and dehydrated transformer oil Conventional Type Transformer Tankincluding stone masonary foundation and all as specified as per manufacturer layout and directed. Make : Indian Transformers and electricals Pvt Ltd/ABB/Ariva/Seimens/VoltampNoteThe under mentioned fittings/ works deemed to be included in the quoted rate:-(a) Transformer oil to be filled upto the recommended level by the manufacture with confirming to IS 335:1953.(b) Lifting lugs and hooks for transfromer and Oil tank complete.(c) Earthing terminal rating and diagram plate complete.(d) Oil filling inlet pipe with gauge complete.(e) Drain outlet pipe with brass gate valve with dummy plug complete.(f) Conservator with level gauage & oil filling complete.(g) Breather with Silica gel complete.(h) Type of connection :Delta/Star.(j)Type of cooling :ONAN. 33 Item No. 27 contd….(k) Vector group :DYn-11.(l)EEL type :Type II.(m) Cable termination boxes with slot on both HT and LT side complete.(n) Pressure release valve.(o) Winding Temperature guage.(p) Temperature guage for oil with all standard fittings as per IS norms complete.(q) Bucholz relay.(r) Explosion vent.(s)Rollers.(t)Fins.(u) Bushing of suitable size and type. 34 Supply , install, testing and commissioning of Indoor typeServo Voltage Stabiliser,250 kVA ,Three Phase, 50 Hz., Input Voltage Range : 300 - 480 V , Output Voltage Range : 415 + 1% V , OIl type , ONAN Cooled,comprising Auto Transformer, Buck & Boost Transformer (Copper Wound with New Filtered & Dehydrated Transformer Oil), Servo Motor, Auto Controlled Solid State Control Circuit and other standard Fittings & Accessories completeall as specified and directed. 35 Supply and fixAutomatic Transfer LoadSwitch,three phase 250 A with Adjustable Time Delay , protection forUV/OV ; Phase Sequence; Single Phasing,option to change from Automatic mode to manual mode completeall as specified and directed. 36 Material and Labour charges forspreading of riddled earth obtained from trenchesfor cable cushioning on top and bottom of cable as specified.for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured) 37 Supply and lay double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 90 mm, complete all as specified 38 Supply and lay double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 75 mm, complete all as specified 39 Supply and lay double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 63 mm, complete all as specified 40 Supply and lay double walled corrugated HDPE pipe inner plain 750 N with RR & NPF nominal dia 40 mm, complete all as specified 41 Supply , installation, testing and commissioning of indoor LT feeder pillar box in replacement, CPRI Approved ,factory fabricated in anfactory having modern fabrication and testing process which includes seven tank pre-treatment process comprising of degreasing, rinsing, de-rusting , rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns . The doors shall be provided with suitable gasket and latch. The rate quoted isincluding PCC foundation for erecting the panel board.The shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back openable single door system lockable / openable by keys from both sides having chromium platedlocks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air.The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustile , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus bar .The bus bar chamber comprising of high conductivity copper bus bar of capacity 600 Amps three phase and half the capacity for neutral.(LT Panel 1) 42 Item No. 35 cont....INCOMING:(a)Air Circuit Breaker ,415 V,400 A, 3 pole, 50kA, Fixed type, Protection type: Thermal-Magnetic release- 01 Nos.(b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 JobOUT GOING: (a) MCCB 250 A, 415V ,4 pole , breaking capacity 36 KA - 01 Nos(b) MCCB 100 A, 415V ,4 pole , breaking capacity 16 KA - 02 Nos(c) MCCB 63 A, 415V ,4 pole , breaking capacity 16 KA - 01 Nos (d) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lampcomplete and all as per standard practice ---4 Job 43 Supply , installation, testing and commissioning of outdoor LT feeder pillar box in replacement, CPRI Approved ,factory fabricated in anfactory having modern fabrication and testing process which includes seven tank pre-treatment process comprising of degreasing, rinsing, de-rusting , rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns . The doors shall be provided with suitable gasket and latcincluding PCC foundation for erecting the panel board.Feeder piller shall be suitable to accommodate the following as specied and as directed.:- OUTER SHELL : The outer shall be made out of 3.15 mm thick CRCA sheet &MS angle section 50x50x6 mm frame, factory fabricated with front & back openable, double door system lockable/openable by keys from both sides having chromium platedlocks. ‘U’ type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate of thickness 3.15 mm powder coated having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated Siemens grey structural RAL 7032 shade. 44 Item No. 36 cont....INNER SHELL : inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back open able single door system lockable / openable by keys from both sides having chromium platedlocks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air.The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustile , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus barThe bus bar chamber comprising of high conductivity aluminium bus bar of capacity 400 Amps three phase and half the capacity for neutral.(LT Panel - 2) INCOMING(a) MCCB 415 V,250 A, 4 pole breaking capacity 36 KA- 01 Nos.(b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING(a) MCCB 125 A, 415V ,4 pole , breaking capacity 16 KA - 02 Nos(b) MCCB 63 A, 415V ,4 pole , breaking capacity 16 KA - 02 Nos (c) MCB TPN 16 A, B Curve,breaking capacity 10 KA - 02 Nos (d) MCB DP 16 A, B Curve,breaking capacity 10 KA - 03 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lampcomplete and all as per standard practice ---4 Job 45 Material and Labour Preparation of new surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts ,Priming plastered and other surfaces with alkali resistant priming paint , Applying two coats of cement paint complete all specified and as directed. 46 Supply and fix GI bracket made out of 32 mm dia GI pipe length 1.50m,bent to an angle of 30 degree andfixed with 40mm x 6mm flat iron, including suitable 02 setofclamps withnut , bolts ,and washers for fixingof light to pole, complete all as directed. 47 Supply , erection, testing ofmaintainance free chemical earthing byauguring & installation of Carbon Coated M.S Pipe(pipe - in - pipe) with copper plated welded busbar terminal . Carbon Coated M.S Pipe shall have Outer Dia is 101 mm with a wall thickness of 2 mm , Inner Dia is 48 mm with a wall thickness of 2.6 mm,length 3m , Internal Corrosion Protection by corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance., and fill with (a) Eco friendly backfill Compound Electrodite (25 kg) with following properties: Resistivity : < 5 ohm-metre (In ideal moist conditions) ; > 5 ohm-metre (Dry Conditions) , Ph Value : 9-13 , High water retention capacity , Hygroscopic , Ionic & Electronic conduction ,Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil (b) Eco friendly backfill Compound Conductolite (25 kg) with following properties: Resistivity : < 0.5 ohm-metre (In dry conditions) & Resistivity is not moisture dependant,Ph Value : 8.0 - 9.0, Electronic & Ionic conduction, Less susceptible to shrinkage,with hygroscopic & corrosion resistive properties(c) Eco friendly backfill Compound Conductolite with following properties: Soil Enhancer / Booster, Powered by Neutralising & Diffusing agents , Ph Value : 7.0 - 9.0 , Ionic conduction, Forms an aqueous solution ,Positive water soluble agents , reduces the soil resistivity, forms an aqueous solution that creates conductive roots in the immediate environment of the earthing system which enables dissipation of fault current smoothlyand connecting with earth strip &covering with heavy dutypolyplastic earth pit chamber cover 48 Supply and fix in cable trench /wallPolyolefin Injection-molded cable channel (Cable Tray) of size width (int. / ext.) 240 / 340mm, height (int. / ext.) 155mm / 230mm, length 1 meter (tolerance in dimensions +/-10mm) min weight per meter-8kg (top and bottom), fire protection class K1 in accordance with DIN 53438 Part-2, Load bearing strength (minimum) - =15 kN at room temperature, channel attachable to each other with male-femaleswallowtail connectors and having suitable detachable coverall as specified and as directed. 49 Supply and fix in wall from ground levelupto a height of 24 m the Polyolefin Injection-molded cable channel of size width (int. / ext.) 240 / 340mm, height (int. / ext.) 155mm / 230mm, length 1 meter (tolerance in dimensions +/-10mm) min weight per meter-8kg (top and bottom), fire protection class K1 in accordance with DIN 53438 Part-2, Load bearing strength (minimum) - =15 kN at room temperature, channel attachable to each other with male-femaleswallowtail connectors and having suitable detachable coverall as specified and as directed. 50 Supply and fixcable route indicator 150mm dia 3mm thick made out of cast aluminum duly marked with MES , LT UG Cable 433 V or HT UG Cable 22 kV &fixed on 40x40x6mm angle iron support embedded in PCC 1;2:4 type B1 using 20 mm graded (300 x 300 x 400 mm size) and painted with 2 coats of anticorrosive paint Blue (LT Cable)/ Brown (HT Cable) and over a coat of red oxide primer all as specified and as directed. 51 Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the glade suitable for cable size 72-78 mm diacomplete all as specified and as directed . 52 Supply and fix brass double compression cable gland with bright nickel plated finish , weather proof , with sealing ring made of Neoprene/Nitrile/Natural Rubber, IP 67 , size of the glade suitable for cable size 3.5C 185 Sqmm complete all as specified and as directed. 53 Supply and fix double compressionstain less steel gland for fixing armoured cable in panel of size 3½ core 50 sq mm to 70 sq mm complete all as specified and as directed. 54 Supply and fix double compressionstain less steel gland for fixing armoured cable in panel of size 2 core 10 sq mm complete all as specified and as directed. 55 Supply, installation, testing and commissioning of CPCB IV+ Norms silent Diesel Engine driven generating set 415 Volts, 160 KVA, 3 Phase, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator both mounted on a common base frame including accoustic enclosure suitable for ambient condition and confirming to condition under IS 4722,BS 5514/5000, ISO 8528/3046 with following :- Make : (i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI standard. (ii) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil and final successful acceptance test. (iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overload In presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (iv) Rate quoted shall be deemed to be included in making necessary holes to walls and making good to distrubed surfaces of original specification and connection up all as specified and directed. 56 Item No 47 cont....A) Alternator :- Synchronous Alternator of 160 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 phase, 4 wire, 415 volts, 50 Hz, 1500 RPM, confirming to BS 5000/IS 4722 self exicited self regulated through an AVR screen protected drip proof IP 23 enclosure brush less design with winding In pole faces, insulating class H and voltage regulation of ± 1% at ratedvoltage from no load to full load and shall be in position to generate supply Voltage Regulation with in ± 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 5000/ IS - 4722. i) Excitation : Self Excited ii) Regulation performance: The voltage is kept constant with +1 %, manual voltage adjustment within ± 5% . iii) Frequency regulation ± 1% iv) 2 runs of UG copper cable (control cable) of suitable size from Alternator to AMF is deemed to be include in quoted rate. (B) Diesel Engine: - Adequate capacity Diesel engine suitable for 160 KVA coupled drive independently with alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories, directly coupled through flexible type coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISO - 8528 with with standard accessories all as specified and required for safe handling and operation salientfeatures of accessories shall be as under:- 57 Item No 47 cont....(i) Fly wheel with housing (ii) Cooling system :- Mounted radiator with fan & belts.(iii) Cooling Water pump: - Centrifugal type belt driven. (iv) Electrical starter motor 12 V DC.(v) Battery charging alternator(vi) Mechanical Governer(vii) Spin on Fuel filter(viii) Spin on full flow lube oil filter(ix) Residential Silencer(x) Air cleaner (Paper element type)(xi) Recovery Bottle Safeties for LLOP/HWT(xii) First Fill of lube oil and coolant(D) Batteries:- 1 No Maintenance free Batteries of 12 V of suitable capacity complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals completewith initial charge and initial fill of electrolite all as specified. Make:- CUMMINS PULSE/ EXIDE / AMRON (produced by main / original manufacturer)(E) Handling and operation : Salient features of accessories shall be as under: i) Starter gear ring ii) Start and stop push buttoniii) Ignition key / Switch iv) Radiator with blower fanv) Corrosion inhibitor coolant vi) Paper element filters for fuel, lub oil and by pass.vii) Electronic governer controlled direct fuel injection systemviii) Fly wheel housing and fly wheel. 58 Item No 47 cont....(F) Generator Monitoring Panel: Comprising of following :(a) Gen set controller connected micro process integrated Generator set monitoring metering, governing, protection and control system with built in torque matchedvolts/Hz/overload controller with necessary hardware/ software etc.(b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annunciations (e) Cyclic cranking (f) Auto/manual start/ stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity upto 95% (j) Remote monitoring capabilty through separate Interface modules (k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed (RPM), run hours, DC voltage, 3 phase volts and 3 phase Ampheres, frequency, KW, KVA, power factor (l) Safety Controls : - Engine low lube oil pressure, high water temparature and over speeding of engine. (m) Coupling arrngement : - Flexible coupling, fly wheel to suit flexiablecoupling fly wheel houslnq. (n) Accessories :- AVM Pads built or separtely mounted to manufacturer base frames. (o) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. 59 Item No 47 cont....G) CONTROL PANEL:- Genset control panel of 14/16 Gauges CRCA sheet and powder coated for a weather proof long last finish consists of following parts :-i) Standard Engine Instrumentation.ii) PSO 600 control panel which measures:- (a) Individual Phase Current(Amps)(b) Phase Voltage (Volts)(c) Generator output frequency (Hz)(d) Engine water temperature (Deg C)(e) Lube Oil pressure (kPa)(f) Working Hours(iii) MCB C curve of suitable rating(iv) LED indications for main functions(v) Current Transformers(vi) Instrument fuses duly wired and ferruled. 60 Item No 47 cont....(H) Acoustic enclosure: Enclosure Is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed In sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-i) Custom built product for various equipments, with ensure the optimum performance without duration. ii) Rugged in construction maintenance free and modular designswhich facilitate easy at site.iii) CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 formaximum sound absorption. Acoustic layers are supported by perforated sheets iv) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be bette life of the enclosure against weathering action. v) Special paint treatment with pure polyester powder / epoxy to beprovided for better weather resistance. vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. vii) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to used. viii) Working space is to be provided around the equipment for easy maintenance / repairs. 61 Item No 47 cont....ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. x) A see through transparent window (glass or acrylic) In front of engine panel to be provided for monitoring the operation. xi) Ducting if required, belows, mechanical hardware like locks,hinges fasteners etc., to be provided. xii) Deliverables. As per manufacturer Design 75 dBA; @ 1 mtr at 75% load under free field conditions.The temp Inside the enclosure will be within as per manufactrurers recommendations above ambient temp. xiii) The enclosure should be provided with LED light fitting for Inside illumination xiv) The battaries should be placed inside the enclosure beside theDG Set on a suitable inlsulated plat form. xv) The DG Set should be provided with external Emergency stop push button. xvi) The accoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.Make for Accoustic panel : DG Set OEM 62 Item No 47 cont....The following items are deemed to be included in the rate Quotedfor DG set:-(a)SEMI ROTARY PUMP :-Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 metre flexible hose pipe of suitable size heavy duty for suction of diesel from barrel.(b) TOOLS KIT(i)Box type spanner set consisting of 12 spanner - 01 Set(ii)Spanner D/E ( 05 mm to 27 mm ) - 01 set(iv)Insulating cutting plier 8 long - 01 No(E) Civil WorksAll civil works including PCC platform for mounting DG set and related to foundationsequipments including making good andexisting structrure of distrubed during installtion andcommissioning of genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended bythe manufacturer. Note : a)The contractor shall arrange for artificial load for testingfor final testing of DG Set at site and the cost is deemed to beincluding in the quoted rate.(b)DHPP for testing purpose shall be supplied by the contractors withoutany extra cost.(c) hard standing 2 meters all around the DG Set enclosure and plat form should minimum of a height of 60 cms above normalground level. 63 Supply and installation of Franklyn type Lightning Arrester using thefollowing items : (a) Franklyn type Lightning Conductor, sphere made of copper with diameter of 76mm. Five tapered spikes, one at centre and four at different angles are made of copper having dia of 8 mm and Length 68 mm are connected to sphere. The sphere is connected to the main pipe made of copper having a length of 1000 mm and diameter of 25mm with thickness of 2mm. A square copper base plate of 75 mm X 75 mm having 5mm thickness is used for securingLightning Conductor on Flat surface.- 1 SET(b) Mast for Conventional rods used for cemented Flat surface based Installation with Circular Base Plate having main Pipe of length 6000mm with Outer diameter as 60mm & Thickness as 4.5 mm Top pipe of length 4000 mm having outer diameter as 48mm and thickness as 3.2 mm is connected via flange joint with main pipe. Top pipe goes 500 mm inside main pipe through flange joint for better stability. Bottom Plate of diameter 220 mm & having thickness as 10 mm is welded directly with the main pipe to form a single piece without any joint for stability at bottom. Gusset Plates are welded as a supporting feature between bottom plate and main pipe. The Bottom Plate is furnished with 4 nos of 16mm Holes for securing the mast on the Cemented flat surface. Made of material is G.I ; The total height of mast is 9500mm Base Plate details: Circular Plate of diameter 220 mm & having thickness as 10 mm is welded directly with the pipe to form a single piece without any joint for stability at bottom. Gusset Plates are welded as a supporting feature between Circular plate and main pipe. Circular Plate is furnished with 4 nos of 16mm Holes for securing the mast on the Cemented flat surface. - 1 SET 64 Item No 48 continued.. (c)4 Nos of Insulators and 4 Nos of SS Bolt Nut - 1 SET (d)Lightning Impulse Counter , 80 x 120 x 85 mm BoxMinimum Current ( I min) : 1KA , Certified & Tested by CPRI Bangalore - 1 No. (e) Rod To Strip/Rod Connector ,MOC : SS, Application :Conductor Rod (8 mm -10 mm Dia) to Strip (upto 30 X 3) / Conductor Rod (8 mm - 10 mm Dia) to Conductor Rod (8 mm - 10 mm Dia) as a Test Joint between Lightning and Earthing conductors - 01 set(f) Conductor Rod 8 mm Dia , Semi - Hard conducting rod of aluminium - 34 Nos.(g)Roof Conductor Holder With Flat Base ,MOC : Polyamide, for Securing the Conductor Rod (8 mm - 10 mm Dia) on to the surface of PEB Shed at every 1 meter , Flat clamp of stainless steel is provided at bottom for securing holder - 34 Nos.Assembling & fixing of Lightening Arrester System at a height of 24 meters and fixing theEarth Continuity Conductor rod from ground level upto the height of 24 meters & connecting with Lightening Arrester systemcomplete all as specified and as directed. 65 Supply , install and testing of Chemical earthing for Lightening Protectionsystem using the following items : - (a) Copper Bonded Rod(s) with terminalmanufactured using Low Carbon High Tensile Steel , rod dia - 17 mm , over all length is 3000 mm ,Copper plated welded busbar 50 x 6 x 150 , External Corrosion Protection : Copper Plated (250+ microns) (b) Eco friendly backfill Compound Electroditewith following properties: Resistivity : < 5 ohm-metre (In ideal moist conditions) ; > 5 ohm-metre (Dry Conditions) , Ph Value : 9-13 , High water retention capacity , Hygroscopic , Ionic & Electronic conduction ,Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil - 50 kg (c) G.I.Strip of 25mm x 6mm - 7 meter(m) Poly Plastic Earth pit Chamber Cover Heavy Duty - 1 No. complete all as specified and as directed. 66 Supply and installation of LED aviation light at a height of 10 m ,Medium Intensity,18W, ICAO Type B , Intensity >2400 cd,must have radio suppression conforming to IEC 61000-6-4-2001/BS800, Omni-Directional light which conforms to ICAO, Input voltage to the controller of the light 220V AC , SMPSfor output voltage 20 V DC to 40V DC,Flashing light , Flash Rate 20 - 60 FPM, IP 65 , water proof through EPDM Gasket and Sealant, Light Color -red, Radial Emission as per CISPR 11, Horizontal Coverage 360 °, Vertical Beam Spread > 3 ° ,with Bird Spikeat the top with fixtures to mount on pole complete all as specified and as directed. 67 Supply and fix double compressionstain less steel gland for fixing armoured cable in panel of size 2 core 6 Sq mm complete all as specified and as directed. 68 Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. 69 Design, supply, install, testing & commissioning goods lift , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic& manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified The lift shall be provided with and including the following:- (a) Alarm speaker for alarm system to be fixed, stop button in car with rechargeable arrangement for battery(b) Four sleek circular LED lights fitting in false ceiling(c) Overload warning indicator both audio and visual type with tripping system having relay etc. (d) Set of three Nos limit switches at the bottom and top most position of lift. (e) Display indicating panel, power control cables.(f) Testing of Govt approved lift inspector (g) Marking on lifts pit and lift room (h) Mirror of 6mm thickness of suitable size on one wall inside the car 70 Item No.53 Cont...(j)Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed on all the floors) and stop button in car with rechargeable arrangement for battery.(k) Aluminium chequered plate (3mm thick) as flooring. (l) Car size shall be conforming to IS-3534-1976 and body to be of stainless steel of 16 gauge mirror finish with stainless steel hand rail. (m) Front door, operations with a minimum time of 10 seconds and upto a maximum timeof 30 seconds. (n) Hand rail, Specification plate. (o) Wire rope of adequate size as per relevant IS and as per manufacturer specification. (p) Suitable earthing pit earthing of lift as per IS and as required technically. (q) One sleek circular PVC heavy duty fan in false ceiling.(r) Fire man switch. (s)Automatic rescue device during power failure with capacity of battery designed for 45 minutes including manual operation provision (t) Other standard fixtures and fittings like guide rails, sheaves, counter weight with guard, buffers, gears, brakes, control panel, motor, locks, governor, car operational panel, power control and trailing cables complete. Note :-The rate quoted shall beIncluding the rate for comperhensive maintenanceperiod for two years after completion of the work.ie during defect liability period 71 Item No.53 Cont...Notes:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacment of minor consumables like topping of gear oils/ grease/ door rollers/ relays/ door belts/ gate lock contacts and any hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer is deemed to be included.(ii) Preventive maintaince consists of carrying out routine check by skilled personnel as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts, topping up of oils as per Lubrication chart. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintaince registeres shall be maintained and signed by site Engineer and contractor.(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. 72 Item No.53 Cont...(vi) All maintenance work shall be carried out by well qualified tradesman and supervisor of OEM.(vii)The quoted rate shall be deemed to be included the above aspects and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationary and other miscellaneous items and all other major and minor spare parts.(viii)One qualified diploma Engineer shall be employed whenever required along with one helper having sound knowledge and well experience in maintenance of lift. All the staff employed for maintenance will be reported to AGE E/M office daily will give day to day progress duly entered in the registers. (ix)The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after defects liabilities period directly or through their nearest authorised/accredited agencies service personnel.The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work order No.1(x) The quoted rate deemed to included yearly testing of lifts from authorised lift inspector. 73 Supply , install, testing and commisioning ofsplit Air Conditioner of 1.50 TR Capacity with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and out door units) complete with cordless remore control unit, with BEE 5 star rating, with minimum 10 yrs warranty on inverter compressor,completeall as specified and as directed. Note 1 : Rate quoted is inclusive of the following. (i) drilling hole on the brick wall to faciltate routing copper pipe drain pipe and cable from indoor unit outdoor unit (ii) Sealing thehole from outside, after installation, with white cement (iii) Pressure testing, cooling performance check and product demonstration (iv) Material and labour for fixing Remote stand in wall. Note 2 : Copper pipe & interconnecting cable for connecting Indoor and outdoor unit required over and above the quantity supplied by OEM shall be measured seperately under respective item. 74 Supply , install, testing and commisioning ofsplit Air Conditioner of 2.0 TR Capacity with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and out door units) complete with cordless remore control unit, with BEE 4 star rating, with minimum 10 yrs warranty on inverter compressor completeall as specified and as directed. Note 1 : Rate quoted is inclusive of the following. (i) drilling hole on the brick wall to faciltate routing copper pipe drain pipe and cable from indoor unit outdoor unit (ii) Sealing thehole from outside, after installation, with white cement (iii) Pressure testing, cooling performance check and product demonstration (iv) Material and labour for fixing Remote stand in wall. Note 2 : Copper pipe & interconnecting cable for connecting Indoor and outdoor unit required over and above the quantity supplied by OEM shall be measured seperately under respective item. 75 Supply and fixing of GI powder coated brackets ,for fixing of split ACs including grouting with suitable size fastners complete all as specified and directed. 76 Supply and fixing Copper pipe 1/2 diawith foam insulation including connecting complete all as specified and directed. 77 Supply and fixing Copper pipe 1/4 mm diawith foam insulation including connecting complete all as specified and directed. 78 Supply and fix Drain pipe PVCfrom indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete all as specified and directed. 79 Supply and fix four core wire 1.5 sqmm interconnecting cable IDU - ODUcomplete all as specified and directed. 80 Supply & fixingplants forhedges by digging 0.30mx0.45m trenches, filling the trench with approved digging material upto 0.30 m and remaining height of 0.15 m with mixture of fresh garden soil and manure in ratio 4:1 and neem cake (25g) + vermi compost (50g). Mixing garden soil & manure throughly well and planting healthy saplings.Removing & depositing the excess soil at low lying area as directed by Engineer-in-Charge.The type of plant shall be Clerodendron or Duranta or Murrayaexotica, Boughinvillea or as approved by Garrison Engineer. 81 Supply and fixing ornamental shrubs plants by digging pit 0.45m x 0.45m x 0.45 m, removing and conveying unwanted stuff to a required distance as directed, filling the pit with excavated material upto 0.30m and remaining height of 0.15m with mixture of fresh garden soil and manure in (4:1) ratio and neem cake (25g) + vermi compost (50g). Antitermite treatment, watering,planting healthy shrubs, removing & depositing the excess soil at low lying area as directed by Engineer-in-Charge. The type of plant shall be Ixora,Tecomariacapensis, Allamanda, Bougainvillea, Hibiscus, Galphimia, Aricapalm, Fox style farm, Traveler Palm, Yellow Bamboo, Bluemaria pudica or as decided by Garrison Engineer/users. 82 Ornamental shrubs plant of height 5 feet 83 Ornamental shrubs plant of height 3 feet 84 Ornamental shrubs plant of height 1 feet 85 Supply and fixing bermuda grass (Turf method) by filling the lawn area with fresh garden soil and manure.Manure @ 125 Kg/500 Sqft. Mixing garden soil & manure thoroughly well. Levelling, Neem cake (2.5 Kg)+ Vermi compost (2.5 Kg) for 500 Sqft. Anti termite treatment, lawn mowing, fertilizer, manure, pesticide application. Lifting and turfing the grass.Note: (a) The quoted rate is deemed tobe inclusive of all preparatory work such as dressing of existing ground surface for fixing the bermuda grass and removing/depositing the surplus soil to a locationas directed by Engineer-in-Charge. (b) The contractor to maintain the bermuda grass for03 monthstill it spreads to full surface by watering, manuring, replacing the rotted grass with new grass which is also deemed to be inclusive of quoted rate. 86 Sch A Part-XIV PHASE-II (M&O OF GOODD LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 53FIRST YEAR DURING DEFECT LIABILTY PERIOD.) 87 Manning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user for during first year of Defect liability period complete all as specified and as directed. 88 Sch A Part-XV PHASE-III (M&O OF GOODD LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 53SECOND YEAR DURING DEFECT LIABILTY PERIOD.) 89 Manning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user during second year of Defect liability period complete all as specified and as directed. 90 Note For SL No: 64 to 65.01 ( i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge.(ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 hours and second shift shall be from 1430 hours to 2230 hrs.(iii) In case of non function of passenger lift, the goods lift installed in the same building shall be operated as directed.(iv) The work shall be suprevised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BOQ shall be deemed to be including the same.(v) The unit rate is deemed to include for maintaining log books, record of repair / replacement of perished / underviceable, minor adjustment, minor repairs of all accessories, cleaning/ up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tool shall be available in a tool box with the operator in the shifts for smooth functioning of lifts.(vii) Conveyance and communication system like mobile phone etc. shall be provided by the bidders/Service providers to all lift attendants / Supervisors.(viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. 91 Note For SL No: 64 to 65.01 (ix) The Bidders shall abide by the latest labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the State/central government from time to time whichever is higher. The Biddrs shall also insure the workmen employed on the job.(x) The Biddrs is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess etc, as applicable and shall be deemed to be included for the same.(xi) Dress Code: The bidders shall provide the workmen with dark blue colour uniform (formal pant & shirt) with labels showing / printed i.e. Name of the firm and designation on front and on the back of the T-shirt along protective clothing / gear. The bidders shall also provide shoes to the workers and he persons shall not be allowed to enter the work site without wearing shoes.(xii) Insurance: The Bidders shall be responsible for all Accidents / Injuries hapenning to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishanding / worng operation / lack of knowledge of safety precautions or on account of any circumstances beyound his / their control, the bidders shall be solely responsible for setting all claims of copensation to the deceased falling which department will have a right to recover any sum indicated / claimed by labour commissioner / court authorities. No claim whats over will be entertained in this regard. No compensation is enable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 92 Sch A Part-XVI PHASE-VI (FIRST YEAR COMPREHENSIVE MAINTENANCE & M&OFOR GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 53AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) 93 Comprehensive mainenance of electrically operated Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic& manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed 94 Manning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of userduring 1st year after expiry of Defect liability period all as specified and directed 95 Sch A Part-XVII PHASE-V (SECOND YEAR COMPREHENSIVE MAINTENANCE & M&OFOR GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 53AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) 96 Comprehensive mainenance of electrically operated Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic& manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed 97 Manning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user during 2nd year after expiry of Defect liability period all as specified and directed 98 Sch A Part-XVIII PHASE-VI (THIRD YEAR COMPREHENSIVE MAINTENANCE & M&O FOR GOODS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 53AFTER EXPIRY OF DEFECT LIABILTY PERIOD.) 99 Comprehensive mainenance of electrically operated Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic& manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed 100 Manning & Operation of electrically operated lifts by providing services of one lift operator (semi skilled) Metric / SSC qualified with 2 to 3 years of relevant experience for main building comprising of Goods lift (1 No) , 1000 Kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply in two shift for 12 month including sundays and holidays in two shifts a day including taking care of form any pilferage, theft of damage etc to ensure smooth and trouble free operation of lifts to the entire satisfaction of user during 3rd year after expiry of Defect liability period all as specified and directed 101 Note for SL No: 66.01,67.01 & 68.01:-(i)Comprehensive maintenance consists of preventive and breakdown services including replacment of minor consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and any hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the above(ii)Preventive maintaince consists of carrying out routine check by skilled personnel as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart. (iii) Breakdown maintaince consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation. (iv) Fortnightly,quarterly maintaince registeres shall be maintained and signed by site engineer and contractor.(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. 102 NOTE for SL No: 66.01,67.01 & 68.01:- Conte...(vi) One qualified diploma Engineer shall be employed as when required along with one lift mechanic and one helper having sound knoweledge and well experience in maintenance of lift. All the staff employed for maintence will be reported to AGE E/Moffice daily and will give day to day progress duly entered in the registers.(vii)The quoted rate shall be deemed to be included the above aspects and for consumebles such as timely topping up/replacement of gear oils,acrylic covers,fuses,copper cables,hardware like bolts,nuts,emery papers,grease,waste cotton,stationary and other miscellaneous items etc(viii) The tenderer shall submit MOU from the original manufactrer of the lift for comprehensive maintenance to undertake comprehensive maint after defects liability period directly or through ther nearest authorised/ accredited agencies services persels. MoU shall be submitted at least 6 months prior to issue of completion certificate of main contract as per work order no 1.(ix) the above work incl yearly testing of lifts from authorised lift inspector all as specified and as directed. 103 Note for SL No: 66.02,67.02 & 68.02:-( i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge.(ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 hours and second shift shall be from 1430 hours to 2230 hrs.(iii) In case of non function of passenger lift, the goods lift installed in the same building shall be operated as directed.(iv) The work shall be suprevised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BOQ shall be deemed to be including the same.(v) The unit rate is deemed to include for maintaining log books, record of repair / replacement of perished / underviceable, minor adjustment, minor repairs of all accessories, cleaning/ up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tool shall be available in a tool box with the operator in the shifts for smooth functioning of lifts.(vii) Conveyance and communication system like mobile phone etc. shall be provided by the bidders/Service providers to all lift attendants / Supervisors.(viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. 104 NOTE for SL No: 66.02,67.02 & 68.02:- Conte...(ix) The Bidders shall abide by the latest labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the State/central government from time to time whichever is higher. The Biddrs shall also insure the workmen employed on the job.(x) The Biddrs is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess etc, as applicable and shall be deemed to be included for the same.(xi) Dress Code: The bidders shall provide the workmen with dark blue colour uniform (formal pant & shirt) with labels showing / printed i.e. Name of the firm and designation on front and on the back of the T-shirt along protective clothing / gear. The bidders shall also provide shoes to the workers and he persons shall not be allowed to enter the work site without wearing shoes.(xii) Insurance: The Bidders shall be responsible for all Accidents / Injuries hapenning to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishanding / worng operation / lack of knowledge of safety precautions or on account of any circumstances beyound his / their control, the bidders shall be solely responsible for setting all claims of copensation to the deceased falling which department will have a right to recover any sum indicated / claimed by labour commissioner / court authorities. No claim whats over will be entertained in this regard. No compensation is enable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 105 SIGNATURE OF CONTRACTOR
|