Quotation are invited for Service field breakers of GT generator excitation system in L1 station SERVICES FOR PREVENTIVE MAINTENANCE & REPAIR OF GERAPID BREAKER#S QTY: 1NO.##INSPECTION & SERVICING ACTIVITIES INCLUDE1)#VERIFICATIO N OF CORRECT OPERATION OF ALL COILS WITH RESPECT TOCONTROL VOLTAGE & ACCESSORIES.2)#CHECK & VERIFY CONDITION OF MAIN CONTACTS, ARCHI NG HORN, PRECONTACTS3)#CHECK & VERIFY CONDITION OF SEPARATION PLATES & ARC CHAMBER4)#CHECK & VERIFY MECHANICAL OPERATIONS (MANUAL OP EN/CLOSE OPERATIONSWITH CB ON/OFF STATUS)5)#CHECK & VERIFY CONDITION OF LATCH & KS-COMPENSATOR6)#CHECK & VERIFY ELECTRICAL OPERATION S (ELECTRICAL OPEN/CLOSE WITH CBON/OFF STATUS, SHUNT TRIP7)#COIL, UNDERVOLTAGE COIL & AUXILIARY CONTACTS)8)#INSULATION RESISTANCE & CONTACT RESISTANCE TEST OF CB#S9)#ALL DEFECTS AND/OR MALFUNCTIONS DISCOVERED DURING INSPECTION &TESTING SHALL BE DULY RECTIFIED & FI NAL TESTING AND CERTIFICATION FORTHE BREAKER TO BE PROVIDED CONFIRMING ITS INTEGRITY TO INSTALL IN THEEXCITATION SYSTEM.##PARTY CAN INSPECT THE BREAKERS BEFORE SUBMITTING THE QUOTE.##QUOTE SHOULD BE IN AED WITH DETAILED SPLIT UP AGAINST THE QUOTEDPRICE.##PARTY SHO ULD PROVIDE WARRANTY OF AT LEAST ONE YEAR.##PAYMENT WILL BE DONE AGAINST ACTUALS UPON COMPLETION OF THE WORKCERTIFIED BY DEWA ENGINE ER (ON PRO-RATA BASIS).##COLLECTION OF THE BREAKER FROM PARTYS WORKSHOP AFTER COMPLETION OFTHE WORKS WILL BE UNDER DEWA SCOPE.##DET AILS OF THE BREAKER:DC BREAKER ; GERAPID 4207 ; GE DRIVE SYSTEM : 151X1215GD015A01 ; SERIEALNO:502283 ; WIRING DIAGRAM NO. 36/102010 001 ; SOLENOID VOLTAGE 125 VDC; ACCESSORIES VOLTAGE 24VDC SERVICES FOR PREVENTIVE MAINTENANCE & REPAIR OF GERAPID BREAKER#S QTY: 1NO.##INSPECTION & SERVICING ACTIVITIES INCLUDE1)#VERIFICATIO N OF CORRECT OPERATION OF ALL COILS WITH RESPECT TOCONTROL VOLTAGE & ACCESSORIES.2)#CHECK & VERIFY CONDITION OF MAIN CONTACTS, ARCHI NG HORN, PRECONTACTS3)#CHECK & VERIFY CONDITION OF SEPARATION PLATES & ARC CHAMBER4)#CHECK & VERIFY MECHANICAL OPERATIONS (MANUAL OP EN/CLOSE OPERATIONSWITH CB ON/OFF STATUS)5)#CHECK & VERIFY CONDITION OF LATCH & KS-COMPENSATOR6)#CHECK & VERIFY ELECTRICAL OPERATION S (ELECTRICAL OPEN/CLOSE WITH CBON/OFF STATUS, SHUNT TRIP7)#COIL, UNDERVOLTAGE COIL & AUXILIARY CONTACTS)8)#INSULATION RESISTANCE & CONTACT RESISTANCE TEST OF CB#S9)#ALL DEFECTS AND/OR MALFUNCTIONS DISCOVERED DURING INSPECTION &TESTING SHALL BE DULY STANDARD TERMS & CONDITIONS 1) Prices should be DDP delivery duty paid at DEWA stores. 2) Quotation to be submitted only in local currency U.A.E Dirhams 3) DEWA Standard payment terms is 30 days credit from the date of acceptance of material 4) No DEWA staff or his or her relatives up to third degree should have ownership or partnership in your company, and your participation in DEWA tenders / RFQs should not constitute a Conflict or perceived Conflict of Interest. Supplier Registration: https://srm.dewa.gov.ae/irj/portal/anonymous/regis Tender Link : https://srm.dewa.gov.ae/sap/opu/odata/sap/ZSRM_RFX_REG_BID_SRV/AttachmentSet(2412501754)/$value
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 104319636
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.