Separator For The Artery Of The Foot And Hand. The Separator Is Designed For Mechanical Fragmentation And Retraction Of Thrombotic Masses During The Thrombus Extraction Procedure And Ensuring Reperfusion Of Peripheral Arteries. Supplied Complete With An Introducer And A Device For Rotating The Guidewire. The Distal Diameter Of The Conductor Is Not Less Than 0.010” (0.25Mm), Radiopaque Tip, Tip Type Is Straight, Length Is Not Less Than 190 Cm, Working Length Is Not Less Than 30 Cm. Mandatory Presence Of A Surfacing Olive, The Diameter Of The Welding Olive Is No More Than 0.028” (0.71Mm), The Required Diameter Of The Vessel For Using The Separator Is 2.0-3.0 Mm., Reperfusion Catheter For The Artery Below The Knee. Reperfusion Hydrophilic Catheter To Ensure Reperfusion In The Arteries/Veins Of The Leg. The Number Of Segments Of Variable Stiffness Along The Entire Length Of The Catheter Is At Least 8, The Total Length Of The Catheter Is At Least 132 Cm, The Length Of The Distal Part With A Hydrophilic Coating Is At Least 20 Cm. The Catheter Must Be Designed To Ensure Reperfusion Of Peripheral Arteries/Veins Using An Electromechanical Reperfusion Device; The Design Of The Catheter Must Ensure That The Internal Lumen Remains Unchanged During Thrombus Extraction With Vacuum Up To -29.92 In Hg, Reinforcement Along The Entire Length With Double Nitinol Cord With Round And Rectangular Cross-Section. Atraumatic Distal End Edge For Easy Navigation, Ptfe Lined Inner Surface To Reduce Friction During Thrombus Extraction, Number Of Radiopaque Markers On Distal End Of Catheter For Visualization In Any Anatomical Position - 1, Tapered Design For Easy Navigation, Proximal End Equipped With Lewer-Type Adapter For Connection Instruments, Proximal End Id Not Less Than 0.064 Inch, Distal End Id Not Less Than 0.054 Inch, Proximal End Outer Diameter Not More Than 6F, Distal End Outer Diameter Not More Than 5F, Guidewire Compatible - 0.014 - 0.038 Inch., Separator For The Artery Below The Knee. The Seperator Is Designed For Mechanical Fragmentation And Retraction Of Thrombotic Masses During The Thrombus Extraction Procedure And Ensuring Reperfusion Of Peripheral Arteries/Veins. Supplied Complete With An Introducer And A Device For Rotating The Guidewire. Conductor Diameter - 0.014” (0.36Mm), Radiopaque Tip, Straight Tip Type, Length No Less Than 175 Cm, Working Length No Less Than 43 Cm, Weld-Surfacing Available, Diameter Of The Weld-Surfacing No More Than 0.045” (1.14Mm), Required Vessel Diameter For Using The Separator>4 Mm., Xenoprosthesis Of A Blood Vessel (Xenograft) 650 Mm Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 650 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Trap For Removing The Vena Cava Filter. Kit For Removal And/Or Reinstallation Of The Vena Cava Filter Via Jugular Approach: With Straight, Curved Forceps Or With Adjustable Angle Of The Bend Zone. Contents: Catheter-Introducer 9Fr Id (Inner Diameter) - Hd Polyethylene. Expander 9F - Polyethylene. Catheter 7F - Polyethylene. Device With Forceps. Puncture Needle - Stainless Steel. J-Shaped Conductor Is 304 Stainless Steel With Teflon Coating. Wire Diameter Of The Legs (Mm) – 0.4; Material - Stainless Steel; Diameter Of Forceps (Mm) – 12-15; Length Of Tongs (Mm) – 24; The Opening Angle (°) For The Adjustable Device Is 140-145., Reperfusion Catheter For Arteries/Veins Of The Foot And Hand. Reperfusion Hydrophilic Catheter To Ensure Reperfusion In The Arteries/Veins Of The Foot And Hand. The Number Of Segments Of Variable Stiffness Along The Entire Length Of The Catheter Is At Least 8, The Total Length Of The Catheter Is At Least 150 Cm, The Length Of The Distal Part With A Hydrophilic Coating Is At Least 30 Cm. The Catheter Must Be Designed To Provide Reperfusion Of Peripheral Arteries/Veins Using An Electromechanical Reperfusion Device. The Structure Of The Catheter Should Ensure That The Internal Lumen Remains Unchanged During Thrombus Extraction With A Vacuum Of Up To -29.92 In Hg. Reinforcement Along The Entire Length With Double Nitinol Cord With A Round And Rectangular Cross-Section. The Presence Of An Atraumatic Edge Of The Distal End To Facilitate Navigation, Ptfe Coating Of The Inner Surface To Reduce Friction During Thrombus Extraction. The Presence Of One Radiopaque Marker At The Distal End Of The Catheter For Visualization In Any Anatomical Position. Tapered Design For Easy Navigation, Proximal Id 0.041 Or Greater, Distal Id 0.032 Or Greater, Proximal Od 4.1F Or Less, Distal Od 3.4F Or Less, Guidewire Compatible 0.014 To 0.025 Inches., Reperfusion Catheter With A Straight Tip For The Femoral, Iliac Artery, Deep Veins, Fistulas, Pulmonary Embolism. Reperfusion Hydrophilic Catheter For Use In The Femoral, Iliac Artery, Deep Veins, Fistulas, Pulmonary Embolism To Provide Reperfusion. The Number Of Segments Of Variable Stiffness Is At Least 8. The Length Of The Distal Part With A Hydrophilic Coating Is At Least 4 Cm. Purpose - To Ensure Reperfusion Of Peripheral Arteries/Veins Using An Electromechanical Reperfusion Device, The Invariability Of Maintaining The Internal Lumen During Thrombus Extraction With A Discharge Of Up To -29.92 In Hg. Reinforcement Along The Entire Length With Double Nitinol Cord With Round And Rectangular Cross-Section To Ensure Elasticity And Constant Lumen. -1 Number Of Radiopaque Markers On The Distal End Of The Catheter For Visualization In Any Anatomical Position, Tapered Design For Easy Navigation. The Proximal End Is Equipped With A Luer-Type Adapter For Connecting Instruments. The Inner Diameter Of The Proximal And Distal End Is 0.088 Inches, The Diameter Of The Proximal And Distal End Is 8F. Possibility Of Choosing The Type Of Distal Tip: Straight Tip; Tip - 45°, 1 Cm; Tip - 45˚, 1.8 Cm. Choice Of Catheter Length: 85 Cm Or 115 Cm. Compatibility With Guidewire - 0.014 - 0.038 Inches., Catheter For Embolectomy And Thrombectomy Single Channel 5F, Length 80 Cm. Catheter For Embolectomy And Thrombectomy Single Channel, Sterile, Single Use, Size 5F, Length 80 Cm, Color Marking Of The Connector - White. The Diameter Of The Filled Cylinder Is 10 Mm. The Volume Of The Balloon Filled With Liquid Is 1.50 Ml. Catheters For Embolectomy And Thrombectomy Are Designed For The Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., Double-Lumen Microcatheter For Guidewire Redirection And Support. Double-Lumen Support Catheter With Three Guidewire Exit Ports, For Use In The Coronary And/Or Peripheral Vasculature. Designed To Support Guidewires During Vascular Access, Providing A Channel For Local Delivery Of Contrast Agents. An Otw (Over The Wire) Catheter With Two Lumens That Run Along The Entire Length Of The Catheter. Working Length 140 Cm. Compatible With Conductors Size 0.014 Inch / 0.36 Mm Or Smaller. Has Two Depth Indicators Located At A Distance Of 95 And 105 Cm From The Distal Tip. The Presence Of Three Radiopaque Indicators; The First Designates The Distal End Of The Longest Lumen (End Lumen) Of The Catheter; The Second Radiopaque Indicator Is Located At A Distance Of 8 Mm From The Distal Tip, Indicating The Distal End Of The Shorter Lumen (Stylet Lumen) Of The Catheter; The Third - Located At A Distance Of 12 Mm From The Distal End, Indicates The Location Of An Additional Exit Port, 180 ° Opposite To The Exit Port Of The Stylet Lumen. The Distal Part Of The Catheter (25 Cm) Has A Hydrophilic Coating. The Inner Surface Of The Lumens Is Completely Covered With Mdx (Silicone) Coating. A Removable Stylet Is Installed On The Stiletto Clearance. The Presence Of Two Extensions At The Proximal End Indicating The Lumen On The Luer Connections., Catheter For Embolectomy And Thrombectomy, Single-Channel Size 3F, Length 80 Cm. Catheter For Embolectomy And Thrombectomy, Single-Channel Size 3F, Length 80 Cm, Color Marking Of The Connector - Green. The Diameter Of The Filled Cylinder Is 6 Mm. The Volume Of The Balloon Filled With Liquid Is 0.20 Ml. Catheters For Embolectomy And Thrombectomy Are Designed For The Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., Guide Catheter (Cerebral) 8F. Mp 1. Guiding Catheter For Interventional Procedures On The Coronary And Peripheral Arteries. Various Catheter Tip Configuration Options: Judkins Left, Judkins Right, Super Back Up Support, Amplatz, Multi-Purpose, Coronary Bypass, Internal Mammary, El Gamal, Hockey Stick, Ultimate. The Length Of The Catheters Is 100 Cm. Two-Layer Reinforced Catheter Wall. Braid Material: Stainless Steel. The Inner Layer Of The Catheter Is Teflon And The Outer Patented Polymer Coating. Hybrid Technology Braid For Increased Internal Clearance. Pebax Outer Layer Material. Five Zones Of Change In Catheter Stiffness From The Proximal To The Distal End. Narrowing Of The Catheter Tip. Sizes 8 F. Inner Lumen Not Less Than 0.088 (2.2 Mm) For 8F Catheters. Outer Diameter Not Less Than 0.105 (2.6 Mm) For 8F Catheters). Availability Of Catheters Both With Side Holes (To Maintain Capacity) And Without Them. Tip Sizes 3.0, 3.5, 4.0, 5.0, 6.0. Axial Handling 1:1 Resistant To Torsion And Axial Fracture. The Tube Material Is Athrombogenic, With High Flow. The Presence Of A Radiopaque Mark At The Distal End Of The Catheter., Catheter For Embolectomy And Thrombectomy Single Channel 6F, Length 80 Cm. Catheter For Embolectomy And Thrombectomy Single Channel, Sterile, Single Use, Size 6F, Length 80 Cm, Color Marking Of The Connector - Blue. The Diameter Of The Filled Cylinder Is 12 Mm. The Volume Of The Balloon Filled With Liquid Is 2.00 Ml. Catheters For Embolectomy And Thrombectomy Are Designed For The Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., Adhesive For Embolization Of Arteries And Veins. Liquid Embolic System For Embolization Of Lesions Of The Peripheral Vascular And Neurovascular System, Cerebral Avms, Consisting Of A Non-Adhesive Liquid Embolic Agent. Consists Of: Ethylene Vinyl Alcohol (Evoh) Blend Dissolved In Dimethyl Sulfoxide (Dmso), Micronized Tantalum Powder Suspended In Liquid Polymer/Dmso Blend. Tantalum Suspension Time Is 20 Minutes On An Orbital Shaker. Injection Speed Recommended Speed: No More Than 0.3 Ml/Min. Viscosity 18 Centipoise. The Kit Consists Of 1.5 Ml Of Embolisate, 1.5 Ml Of Dmso, 1 Blue Syringe For Dmso And 2 White Syringes For Embolisate, Two Adapters. Setting Time Is No More Than 3 Minutes., Trap For Removing The Vena Cava Filter. A System For Removing And Manipulating Foreign Objects Within The Lumen Of A Vessel. The Presence Of Three Loops. The Hinge Material Is Super-Elastic Nitinol, Providing High Flexibility And Resistance To Fractures. Working Diameter Of The Trap: 6-10, 9-15, 12-20, 18-30 And 27-45 Mm, Shaft Diameter 0.026 Inches. Catheter Length 100 Cm For 120 Cm Trap, Catheter Internal Diameter 062.074 Inches. Trap Length 120 Cm (For Working Diameter 6-45Mm). Catheter Size 6F For Working Diameter 6-20Mm, 7F For Working Diameter 18-45Mm. The Presence Of A Radiopaque Marker Zone At The Tip Of The Catheter. Delivery Catheter Material Is Teflon (Fep). 15° Curved Tip On 6 And 7 Fr Catheters For Better Controllability. The Presence Of A Platinum Thread On The Loops Of The Trap For Improved Visualization. The Set Includes A Trap, A Torque Device, An Introducer And A Catheter. The Trap And Catheter Are Packaged Separately., Separator For The Popliteal, Superior Mesenteric Artery. The Separator Is Designed For Mechanical Fragmentation And Retraction Of Thrombotic Masses During The Thrombus Extraction Procedure And Ensuring Reperfusion Of Peripheral Arteries/Veins. Supplied Complete With An Introducer And A Device For Rotating The Conductor, Conductor Diameter - 0.014” (0.36Mm) 0.014” (0.36Mm), Radiopaque Tip, Tip Type – Straight, Length No Less Than 175 Cm, Working Length No Less Than 43 Cm, Diameter Of The Overlay Olive No More Than 0.055” (1.4Mm), Required Vessel Diameter For Use Separator >4 Mm., Xenoprosthesis Of A Blood Vessel (Xenograft) 700 Mm Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 700 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Blood Vessel Xenoprosthesis (Xenograft) 500 Mm. Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 500 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Blood Vessel Xenoprosthesis (Xenograft) 400 Mm. Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 400 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Diagnostic Conductor 0.035*260Cm. Intravascular Guidewire: Diameter - 0.035 Inches, 0.038 Inches. Length – 75 Cm, 145 Cm, 180 Cm, 260 Cm. Core Material – Stainless Steel. Core Design – Enhanced Support. Coating: Teflon (Polytetrafluoroethylene). Tip Shape – Straight, J 3 Mm, Distal Segment Being Formed 3 Cm. Flexible Tip Length – 1 Cm, 4 Cm, 6 Cm, 7 Cm. Dimensions Are Provided According To The Doctor’S Request., Drug Coated Peripheral Balloon Catheter 0.035 Balloon Catheter (0.014 Otw, 0.018 Otw, 0.035 Otw) Sirolimus Coated, Balloon Diameter (Mm) 2.50, Balloon Length (Mm) 120. Sirolimus Coated Balloon Catheter For Pfa Consists Of A Balloon Catheter Over-The-Wire (Otw) Coated, Polymer-Free Formulation Containing The Drug Sirolimus As An Active Ingredient In A Phospholipid Excipient. It Uses A Proprietary Coating Technology To Transfer The Drug To The Vessel Wall. The Generic Name For Pta Is Sirolimus-Coated Balloon Catheter For Pta.
|