Xenoprosthesis Of A Blood Vessel (Xenograft) 700 Mm Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 700 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Catheter For Embolectomy And Thrombectomy Single Channel 7F, Length 80 Cm. Catheter For Embolectomy And Thrombectomy Single Channel, Sterile, Single Use, Size 7F, Length 80 Cm, Color Marking Of The Connector - Yellow. The Diameter Of The Filled Cylinder Is 14 Mm. The Volume Of The Balloon Filled With Liquid Is 2.50 Ml. Catheters For Embolectomy And Thrombectomy Are Designed For The Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., Reperfusion Catheter For Arteries/Veins Of The Foot And Hand. Reperfusion Hydrophilic Catheter To Ensure Reperfusion In The Arteries/Veins Of The Foot And Hand. The Number Of Segments Of Variable Stiffness Along The Entire Length Of The Catheter Is At Least 8, The Total Length Of The Catheter Is At Least 150 Cm, The Length Of The Distal Part With A Hydrophilic Coating Is At Least 30 Cm. The Catheter Must Be Designed To Provide Reperfusion Of Peripheral Arteries/Veins Using An Electromechanical Reperfusion Device. The Structure Of The Catheter Should Ensure That The Internal Lumen Remains Unchanged During Thrombus Extraction With A Vacuum Of Up To -29.92 In Hg. Reinforcement Along The Entire Length With Double Nitinol Cord With A Round And Rectangular Cross-Section. The Presence Of An Atraumatic Edge Of The Distal End To Facilitate Navigation, Ptfe Coating Of The Inner Surface To Reduce Friction During Thrombus Extraction. The Presence Of One Radiopaque Marker At The Distal End Of The Catheter For Visualization In Any Anatomical Position. Tapered Design For Easy Navigation, Proximal Id 0.041 Or Greater, Distal Id 0.032 Or Greater, Proximal Od 4.1F Or Less, Distal Od 3.4F Or Less, Guidewire Compatible 0.014 To 0.025 Inches., Blood Vessel Xenoprosthesis (Xenograft) 500 Mm. Type Of Prosthesis - Cone-Shaped; Material - Internal Thoracic Artery Of Cattle; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Remaining Shelf Life - 18 Months; Individual Packaging With Storage Solution; Storage Solution 0.3% - Solution Of A Mixture Of Parabens; Dimensions: Length 500 Mm, Distal Diameter 3.0 Mm, Proximal Diameter 6.5 Mm, Catheter For Embolectomy And Thrombectomy, Single Channel 4F, 80 Cm Long. Catheter For Embolectomy And Thrombectomy, Single Channel 4F, Length 80 Cm, Red. The Diameter Of The Filled Balloon Is 8 Mm, The Volume Of The Balloon Filled With Liquid Is 0.70 Ml. Catheters For Embolectomy And Thrombectomy. Designed For Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., The Patch Is Cardiovascular, Of Animal Origin. Dimensions: 10X120 (0.6-0.7) Mm) Material - Bovine Xenopericardium; The Method Of Chemical Cross-Linking Of Biological Tissue Is Epoxy; Individual Container With Storage Solution; Storage Solution - 0.3% Solution Of A Mixture Of Parabens. Size: 10X120 (0.6-0.7) Mm), Catheter For Embolectomy And Thrombectomy, Single-Channel Size 3F, Length 80 Cm. Catheter For Embolectomy And Thrombectomy, Single-Channel Size 3F, Length 80 Cm, Color Marking Of The Connector - Green. The Diameter Of The Filled Cylinder Is 6 Mm. The Volume Of The Balloon Filled With Liquid Is 0.20 Ml. Catheters For Embolectomy And Thrombectomy Are Designed For The Safe And Convenient Removal Of Thrombotic Masses From Arteries And Veins. Embolectomy Catheters Are Made Of Biologically Neutral Material. The Elasticity Of The Catheters Is Adequate To Their Size. The Balloon Is Made Of Latex, Which Allows It To Withstand The Pressure Necessary To Achieve The Desired Effect. The Balloon Is Additionally Reinforced With Silk Thread. Catheters Are Color Coded By Size According To The International Color Code. Color Marks Are Applied At Intervals Of 10 Cm. The Mandrel Is Made Of Stainless Steel, It Facilitates The Insertion Of The Catheter Into The Vessel. The Soft Rounded Tip Minimizes The Risk Of Perforation Of The Vessel Wall. The Other End Of The Catheter Has A Luer-Lock Fitting. Each Catheter Is Marked With The Catheter Diameter And Balloon Capacity. Catheters Are Sterilized Using Gamma Irradiation. Single-Channel Catheters Can Also Be Used To Remove Stones From The Bile Ducts., Absorbable Suture, Coated 2 (3/0) 26 Needle. Absorbable Suture, Coated, And Supplied In Sterile Packaging, Diagnostic Conductor 0.035*260Cm. Intravascular Guidewire: Diameter - 0.035 Inches, 0.038 Inches. Length – 75 Cm, 145 Cm, 180 Cm, 260 Cm. Core Material – Stainless Steel. Core Design – Enhanced Support. Coating: Teflon (Polytetrafluoroethylene). Tip Shape – Straight, J 3 Mm, Distal Segment Being Formed 3 Cm. Flexible Tip Length – 1 Cm, 4 Cm, 6 Cm, 7 Cm. Dimensions Are Provided According To The Doctor’S Request., Vascular Prosthesis (Patch). Knitted Patch For Reconstruction Of The Carotid And Femoral Arteries. Shape: Anatomical And Rectangular. Material - Dacron. Permeability: <10 Ml/Cm2/Min. Under 120 Mm Hg. Thickness: 0.45 Mm. Zero Surgical Permeability Is Ensured By The Collagen Coating. Does Not Require Preliminary Soaking Of The Implant With Blood. Compatible With Various Types Of Suture Materials. High Elasticity Of The Wall Facilitates Easy Puncture Of The Patch With Resistance: ≥ 17 N No Bleeding From Puncture Sites. The Patch Is Easy To Model; When Cutting, There Is No Fiber Separation Of The Wall. Maximum Smooth Inner And Outer Surfaces For Better Hemodynamics And Neointima Formation. Anatomical Shape Size (Mm) 6 X75, 8X75, 10X75. Rectangular Shape Size (Mm) 6 X75, 8X75, 10X75, 14X75, 20X120. Sterilization By ß-Irradiation., Materials For Arterial Embolization 900-1200. Microspheres Are Biocompatible, Hydrophilic, Non-Absorbable, Precisely Calibrated Acrylic Polymer Microspheres Impregnated With Gelatin. Presentation: Pre-Filled 20 Ml Syringe With Standard Luer Lock, Individually Packaged In A Blister Tray Sealed With A Peel-Off Cap. Plastic Screw Cap And Piston. Piston Seal With Three Elastomer Rings. Microspheres Containing Gold Particles Are Colored Red For Ease Of Visualization During Handling And Visibility Of Radiopacity. Contents: 2 Ml Microspheres In Sterile Pyrogen-Free Saline Solution With 0.9% Nacl. Particle Diameter 40-120, 100-300, 300-500, 500-700, 700-900, 900-1200 Microns. Microspheres Are Flexible Particles That Can Be Temporarily Compressed By No More Than 20–30%, Which Facilitates Their Passage Through Microcatheters. Microspheres Do Not Form Aggregates. Compatible With Microcatheter With I.D. 0.008” To 0.038”. Microspheres Are Intended For Occlusion Of Blood Vessels For Therapeutic Or Preoperative Purposes In The Following Procedures: - Embolization Of Hypervascular Tumors And Processes, Including Uterine Fibroids, Embolization Of The Prostate, Embolization Of Arteriovenous Anomalies - Malformations, Hemostatic Embolization, Meningiomas., Bifurcation Vascular Prosthesis. Woven Vascular Prosthesis Impregnated With Bovine Collagen Bifurcation. Biological Inertia, Lack Of Body Response To Implantation. Material – Dacron (Polyester). The Woven Structure Of The Material Is Based On Horizontally Running Threads Above And Below The Main Vertical Line Of Threads. The Material Is Resistant To Long-Term Tensile Loads. The Porosity Level Is Less Than 10 Ml/Min/Sq.Cm At A Pressure Of 120 Mmhg. Art. No Fiber Separation Of The Wall During Dissection. Ensuring Smooth Blood Flow And Laminar Flow From The Prosthesis To The Vessel. Thromboresistance. No Bleeding From Prosthetic Punctures. Compatible With Various Suture Materials. A Thermal Cautery Is Included In Each Package. Free From Formaldehyde, Glutaraldehyde And Carbodiimide. Sterile, For Single Use. Sterilization By Β-Radiation. Main Body Internal Diameter (Mm) X Jaw Diameter (Mm): 14X7, 16X8, 18X9, 20X10. Length 45 Cm. Dimensions According To Customers Request., Double-Lumen Microcatheter For Guidewire Redirection And Support. Double-Lumen Support Catheter With Three Guidewire Exit Ports, For Use In The Coronary And/Or Peripheral Vasculature. Designed To Support Guidewires During Vascular Access, Providing A Channel For Local Delivery Of Contrast Agents. An Otw (Over The Wire) Catheter With Two Lumens That Run Along The Entire Length Of The Catheter. Working Length 140 Cm. Compatible With Conductors Size 0.014 Inch / 0.36 Mm Or Smaller. Has Two Depth Indicators Located At A Distance Of 95 And 105 Cm From The Distal Tip. The Presence Of Three Radiopaque Indicators; The First Designates The Distal End Of The Longest Lumen (End Lumen) Of The Catheter; The Second Radiopaque Indicator Is Located At A Distance Of 8 Mm From The Distal Tip, Indicating The Distal End Of The Shorter Lumen (Stylet Lumen) Of The Catheter; The Third - Located At A Distance Of 12 Mm From The Distal End, Indicates The Location Of An Additional Exit Port, 180 ° Opposite To The Exit Port Of The Stylet Lumen. The Distal Part Of The Catheter (25 Cm) Has A Hydrophilic Coating. The Inner Surface Of The Lumens Is Completely Covered With Mdx (Silicone) Coating. A Removable Stylet Is Installed On The Stiletto Clearance. The Presence Of Two Extensions At The Proximal End Indicating The Lumen On The Luer Connections., Surgilon 2/0. Sterile Surgical Thread, Synthetic, Non-Absorbable, Polyfilament, Made From An Aliphatic Polyamide Polymer With Wax Coating That Makes It Easier To Pass The Thread Through The Fabric. The Materials Used Must Not Have Antigenic Properties. The Thread Should Be Painted Black To Improve Visualization In The Wound. Metric Size 3, Conventional Size 2/0. Needle 1/2 Circle, Stabbing 30Mm. The Length Of The Thread Is Not Less Than 70 Cm And Not More Than 80 Cm. The Number Of Thread Pieces In The Sterile Inner Liner Is 10. The Sterile Inner Liner With Suture Material Is Packaged In An Individual Single Sterile Polymer-Paper Package, Which Is A Package Of Medical Paper And Transparent Polymer, Ensuring The Preservation Of The Sterility Of The Suture Material And Its Functional Properties, Taking Into Account Conditions Of Its Use, Transportation, Storage And Shelf Life; Protecting The Contents From Moisture; Providing Access To Internal Liner In One Movement To Minimize The Time Spent Manipulating The Thread. The Marking Of The Inner Liner Must Contain Name Of The Suture Material, Its Composition, Manufacturers Trademark (If Available), Manufacturers Name, Matrix Code, Catalog Number (If Available), Conventional And Metric Thread Size, Thread Color, Thread Length, Number Of Threads; Indication Of Sterility Indicating The Method Sterilization, Instructions For Single Use. The Threads Should Be Laid In A Figure Eight In A Cardboard Tray, The Threads In The Middle Of The Length Should Be Are Fixed With A Holder Made Of Foil Paper, Which Is Displayed On A Separate Surface Of The Package For Ease Of Removal And Avoidance Tangling Of Threads. Cardboard Packaging Must Have A Special Tear-Off Seal, Separator For The Popliteal, Superior Mesenteric Artery. The Separator Is Designed For Mechanical Fragmentation And Retraction Of Thrombotic Masses During The Thrombus Extraction Procedure And Ensuring Reperfusion Of Peripheral Arteries/Veins. Supplied Complete With An Introducer And A Device For Rotating The Conductor, Conductor Diameter - 0.014” (0.36Mm) 0.014” (0.36Mm), Radiopaque Tip, Tip Type – Straight, Length No Less Than 175 Cm, Working Length No Less Than 43 Cm, Diameter Of The Overlay Olive No More Than 0.055” (1.4Mm), Required Vessel Diameter For Use Separator >4 Mm., Sterile Surgical Thread, Synthetic, Non-Absorbable, Monofilament 5/0 Needle 17, Stent-Graft System For The Abdominal Aorta (Aaa) Included., Dacron Thread (Polyester), Braided, Dyed, Conditional Number 2, Length 75 Cm, With A 25 Needle, Atraumatic, Single Use, Sterile. Synthetic Non-Absorbable Lavsan (Polyester) Thread, Woven, Dyed (Green). Conditional Number 2, Metric Size 5, Thread Length Not Less Than 75 Cm, One Piercing Needle, Needle Length 25 Mm, Needle Bending Degree ½ Circle. Siliconized Needle Made Of High-Strength, Corrosion-Resistant Steel. A Needle With A Laser-Drilled Hole On The Rear End Of The Needle To Ensure Atraumatic Connection With The Thread Due To A Better Ratio Of The Diameters Of The Needle To The Thread. Connecting The Thread To The Needle Using The Method Of Uniform Circular Crimping Of The Needle To Prevent The Appearance Of Traumatic Parts And Burrs On The Needle. The Diameter Of The Needle In The Area Where The Suture Thread Is Attached Should Not Exceed 1.15 Times The Diameter Of The Needle In The Initial Area Of Attachment. The Full Average Needle Life Is At Least 50 Punctures. The Needle Must Be Elastic, Strong, Not Bend, Not Break, The Surface Is Shiny, Without Cracks, Holes, Dents, Scratches And Burrs. Double Sterile Packaging: Inner And Outer Polymer-Paper Bags. The Packaging Should Provide Ease Of Opening And Access To The Needle (The Presence Of Notches Or Other Devices). The Design Of The Carrier Should Ensure Easy Removal Of The Thread And Needle From The Package Without The Formation Of Knots Or Kinks. The Shelf Life Of Medical Products On The Date Of Delivery By The Supplier To The Customer Is: At Least Fifty Percent Of The Indicated Shelf Life On The Packaging (If The Shelf Life Is Less Than Two Years); At Least Twelve Months From The Expiration Date Indicated On The Package (If The Expiration Date Is Two Years Or More)., Materials For Arterial Embolization 700-900. Microspheres Are Biocompatible, Hydrophilic, Non-Absorbable, Precisely Calibrated Acrylic Polymer Microspheres Impregnated With Gelatin. Presentation: Pre-Filled 20 Ml Syringe With Standard Luer Lock, Individually Packaged In A Blister Tray Sealed With A Peel-Off Cap. Plastic Screw Cap And Piston. Piston Seal With Three Elastomer Rings. Microspheres Containing Gold Particles Are Colored Red For Ease Of Visualization During Handling And Visibility Of Radiopacity. Contents: 2 Ml Microspheres In Sterile Pyrogen-Free Saline Solution With 0.9% Nacl. Particle Diameter 40-120, 100-300, 300-500, 500-700, 700-900, 900-1200 Microns. Microspheres Are Flexible Particles That Can Be Temporarily Compressed By No More Than 20–30%, Which Facilitates Their Passage Through Microcatheters. Microspheres Do Not Form Aggregates. Compatible With Microcatheter With I.D. 0.008” To 0.038”. Microspheres Are Intended For Occlusion Of Blood Vessels For Therapeutic Or Preoperative Purposes In The Following Procedures: - Embolization Of Hypervascular Tumors And Processes, Including Uterine Fibroids, Embolization Of The Prostate, Embolization Of Arteriovenous Anomalies - Malformations, Hemostatic Embolization, Meningiomas., Materials For Arterial Embolization 50-100. Microspheres Are Capable Of Absorbing Liquids With A 4-Fold Increase In Particle Diameter, Which Corresponds To A 64-Fold Increase In Volume. An Increase In Particle Size Occurs When They Come Into Contact With Blood, Contrast Medium Or Saline Solution. After Swelling, Due To The Properties Of The Polymer From Which The Microspheres Are Made, Their Size Remains Stable Even After The “Radiation” Of The Drug. The High Absorbency Of The Polymer Allows, For Example, The Absorption Of Up To 75 Mg Of Doxorubicin Per 25 Mg Of Hepaspheres. This Is Due To The Fact That Sorption Occurs Not Only On The Surface Due To Ionic Interaction, But Throughout The Entire Volume Of The Microsphere. It Is Also Possible To Saturate Microspheres With Erinotecan, Mitomycin, Oxaliplatin, Gemzar And Other Drugs. Due To Their Inherent Elasticity, Microspheres Are Able To Temporarily Deform, Which Allows Them To Move Unhindered Through Small-Diameter Catheters. Hydrophilic, Elastic, Compressibility Up To 80%. The Ability To Absorb A Drug, Increasing In Volume By 64 Times, And Then Gradually Emit It At The Point Of Delivery Without Reducing The Diameter Of The Particles. A Specially Created Spherical Embolisate, Each Particle Of Which Fully Corresponds To The Diameter Of The Target Vessel And Thus Ensures Adequate Embolization. A Hydrophilic Surface That Prevents Particles From Sticking Together When Passing Through The Catheter And Inside The Vessel. Elasticity, Allowing Particles To Temporarily Deform For Unhindered Movement Through Small Diameter Catheters. A Special Highly Absorbent Polymer Is Used For Manufacturing. Expanding Microspheres Are Supplied Dry In 25 Mg And 50 Mg Bottles. Dry Particle Sizes Range From 30 To 200 Microns. Particle Sizes In Saturated Form Range From 120 To 800 Μm.
|