|
Lot 1 - Uncovered Bleachers Of Eight Steps, With Assembly And Disassembly In Metallic Modulated Structure, Non -Navy Or Fiberglass -Plywood Floor, Structured With Metallic Profile, Minimum Step Width 0, 61M, 2, 45M Minimal Height, In Metallic Metallic Siding With Metal Silver Color, Consider Spacing Of Metal Color 0, 60M Per Person, Front Catwalk Of 01.70 M Minimum, Height Between 0, 25M Steps In The First Three Steps (Space Intended For Old Age), And Maximum Height Of 0, 33M In The Remaining Steps. Consider Two Grounding, Delta System According To Technical Standard., Lot 1 - Stand Of Eight Steps With Assembly And Disassembly In Metal Modulated Structure, 33M In The Remaining Steps., Lot 2 - Chemical Bathroom, Expanded Polyethylene, Residue Treatment Through Chemicals, With Maintenance, Cleaning And Sanitation Through Vacuum System. Modulated Metal Tubular Structure In The Dimensions Of 01, 00M, 02, Or 03, 00M Long By 01, 10 Meters High, Performed With Galvanized Or Painted Silver Tubes, Minimum Diameter Of 1 ¼ Inch With Minimum Thickness Of 2, 00 Mm Wall. The Internal Divisions Of Closing Of The Fences May Be In Metal Pipes Or Bars, And Cannot Provide Space Greater Than 10 Centimeters Among Them So As Not To Cause Accidents With Children. Links Between Fences Should Be A 30Cm Plastic Clamps And Mooring System That Ensures The Continuity And Stability Of The Line, Allowing The Transfer And Distribution Of Loads Between Them., Lot 4 - Evaporative Climatizers: New Capable Of Producing Climatization Event In Large Environments Without The Presence Of Nevoa Or Droplets: 200M2 To 250M² Area: 220V: Reservoir Autonomy To Full Load: 01 Hour; Water Reservoir With Capacity Adequate To Autonomy; Water Replacement Mode In The Reservoir: Manually, Flow Direction: Vertical And Horizontal Fins; Electrical Connection Plug Of The Equipment In The New Brazilian Standard., Lot 5 - Basic Stand: With 10Cm High Floor, Formica And Aluminum Mounting System Anodized Aluminum Aluminum, Glass Tests In The Spidercom System One Meter Wide, Sconce Lighting Every 03M2, Client Logo With An Area Of 01M2 In Polychromy, With Basic Furniture For Each 09M2 01-Blind Baby, 01 Glass Table Table Set And Four Chairs, 07 Shelves. Consider Grounding, Delta System According To Technical Standard, By Installation., Lot 5 - Built Booth, Following A Special Approved Project, Wood, Mdf, Brick, Iron And Gross Linbri, Vinyl Carpet Floor, Carpet Or Plotted Glass With Lightly Lit Retro Event, Total And Internal Walls, When Necessary, Lighting System To Maintain Standard And Safety Standard. At Least 2 Tripolar Single -Phase Points For Every 4M². Fully Closed Deposit With Door And Key. Note: Present Project Of The Environment With 3D Images And Layout For Approval., Lot 5 - Closed Booth To Receive Climatization And Allow Privacy Of Lectures Or Conferences, Built In The Octanorm Or Similar System, With The Following Minimum Setting: Ts White Ts Panel Testy
|