Supply, Delivery & Installation Of Submersible Pumping Machinery Alongwith Allied Electro-Mechanical Works, Voltage Stabilizer And Automatic Chlorinator ( In Connection With Aug. Work Related To Fhtc ) At Pump House No.Ii ( Replacement ) Under Raharhati W / S Scheme District Of 24 Pgs. ( N ) . ( Sm / 11531 ) - 1 Supply & Delivery At Site The Following Pumping Machinery & Electrical Accessories Etc.Submersible Pumping Machinery Directly Coupled With Water Proof Suitable Size Motor Having Following Specification:P U M Pdischarge ( 750 -Lpm / 45 M3 / Hr ) H E A D: 48 Mtr. ) S H A F T: S.S / Msimpeller:G.M. / Bronze / S.S. / Chrom Steel / Noryloutlet Size: 65Mm / 100Mm / 125Mm.Pump Efficiency Inpercentage:Minimum 65%M O T O Rsubmersible Type, 3 Ph., 50 Hz., 415V, .± 10% / Volts, Rpm—2900 With Wet Type Winding ( Not Less Than 15 H.P. ) ( Make : As Per Approved Vendor List. ) *N.B. ( A ) H / Q Charateristic Curve Chart Of Pump Set Should Be Submitted Before Delivery. ( B ) Test Certificate Of Pump & Motor Should Be Submitted During Delivery. 2 6 Sq.Mm.3 Core, 1.1 Kv Grade, Pvc Insulated, Water Proof Flat Submersible Cable ( Make:- As Per Approved Vendor List. ) . 3 100A, Tp, 415V Main Switch In Sheet Steel Enclose With Neutral Link Rewireable Porcelain Fuse Unit ( Make-As Per Approved Vendor List. ) . 4 Supply & Delivery At Site Ms Fabricated Type Wall Mounted Mcc With Hinge Type Front Door Cover Of Crca Sheet ( 2 Mm. Thick ) And Suitable Locking Arrangement ( Degree Of Protection - Ip 54 ) Having Fully Automatic Programmable Logic Control System With Manual Bypassmode Suitable Operation Of Submersible Pumping Machinery, Chlorinator, Etc. Part By Part According To Present Time Including 1No. 40A Tpn Feeder For Iep. Painting Of The Cubical Mcc By Powder Coated ( Siemens Grey ) Paint Over A Coat Of Primer After Derusting Properly Including Arrangement Of Bracket For Fixing Panel On Wall, All Opening Covered By Rubber Gasket, Cable Entry From Bottomand Two Earthing Stud ( 8Mm. Size ) . The Said Cubical Mcc Comprising Of ( Range – 15 H.P To 25 H.P ) With Star / Delta Starting Arrangement. ( Details Of Panel As Per Technical Specification ) 5 50Sq.Mm. 1.1 Kv Grade, 3 ½Core, Al. Ar.P.V.C.Insulated Cable ( Make:- As Per Approved Vendor List. ) 6 Supply And Delivery At Site Pipes, Valves Specials, Gauges Etc. As Per Following Specification:-A ) 125 Mm. Dia.Upvc Column Pipe With Suitable Thread On Both Side And Pvc Socket At One End With Following Dimension. 7 I ) 3 Mtrs Long 8 Ii ) 1.5 Mtrs Long 9 Iii ) C.I. Adapter ( Top ) 10 Iv ) C.I.Adapter ( Bottom ) 11 B ) Heavy Type Suitable Dia.M.S.Suspension Clamp Made Of 125Mm. X 10 Mm. M.S. Flat With Nuts, Bolts, Washer Etc. 12 C ) I ) 150Mm. Dia.Cidf Sluice Valve 1 No, Cidf Nrv Valve 1 No, Gi Bend, Cidf / M.S.Enlarge, Cidfshortpieceses Of Required Length, Flanged Tail Piece, Cidf Bend, Steel Plug, M.S. Nipple, Flange, Nuts, Bolts Etc. Asper Requirement And As Peri.S. Specification And Other Required Materialsfor The Job I.E.Formaking Completeconstraction Of Delivery & Wash Out Line ( Make :-As Per Approved Vendor List. ) As Per Is 780 / 84 For Sluice Valve And Is-5312 / 84 For Nrv. Test Certificate Of The Meterialsshould Be Submitted At The Time Of The Delivery.N.B.:- M.S. Specials Should Be Minimum 7 Mm. Thickness. 13 Ii ) Three-Phase Actuator Operated Wafer Type Butterfly Valvepn-1.0 Rating Of Norminal Dia 150 Mm. As Per Bs-5155 Having Valve Body Of Ci ( Grade Is 210 Fg 260 ) And Shaft Stainless Steel ( Aisi-410 ) Make-As Per Approved Vendor List., Marsh. Valve - As Per Approved Vendor List. 14 D ) 100 Mm. Dia , 0-7 Kg / Cm2range, Wall Mounted Pressure Gauge Complete With Brass Stop Cocks. ( Make : As Per Approved Vendor List. ) Tubewell Outside The Pump House ( This Cost Includes 15 Mm. Dia.G.I. Pipes Of Required Length & Specials ) . 15 E ) Split Type M.S.Fabricated Suitable Size Tubewell Cover Having Thick- Ness 6 Mm. For Housing Pipe With Necessary Fastening Arrangement Alongwith Provision Of Colomn Pipe, Air Pipe, Cable Entry Gland Etc. 16 F ) Tubewell Outside The Pump House. ( This Cost Includes 15 Mm. Dia. G.I. Pipe Of Required Length And Specials ) . Tubewell Outside The Pump House. ( This Cost Includes 15 Mm. Dia. G.I. Pipe Of Required Length And Specials ) . ( Make: As Per Approved Vendor List. ) 17 G ) Anti - Snapping Safety Device For Above Pump With Supply Of Suitable Size Heavy Type M.S.Clamp And Nylone Rope Ofrequiredlength ( Double ) Including Supplyofall Other Necessary Materials As Required. 18 Supply & Fittingfixingof100 Amps. Fuse Unit ( Both Base & Bridge ) ( Make - As Per Approved Vendor List. ) Inthewallby Supplying Of All Necessary Materials As Per I.E. Rules And Direction. 19 Drawing Of Above Supplied Power Cable In The Wall / Floor By Supplying Of All Necessary Materials As Peri.E. Rules And Direction. 20 Finishing The End Ofpvc Cable By Crimping Methodincluding Supplying Of Suitable Size Cable Gland, Tapes, Socket, Jointing Materialsetc. As Per I.E. Rule And Direction. 21 Installation Of Above Supplied P / Machinery Along With Coloum Pipes, Safety Device , Submerssible Cable Supplied Above Etc.Including Supply Reducer For Pump ( If Required ) . This Cost Includes The Cost Of Interconnection Of Submerssible Cable With Starter Through Conduit Pipes As Required And Also Concealed Manner In The Floor And Ground Including Cutting & Mending Damages Of Floor As Required, As Per Direction. ( This Cost Includes Arrangement Of Derrick And Drawing Of Cable And Supplying Of Lifting Tools & Accessories. ) 22 Fittingfixing Of Above Valves, Specials Etc. With Existingrisingmain By Supplying Of All Necessary Materials As Required To Complete The Work As Per Direction. Thisalsoincludesthecostofpaintingofvalvesand Specialswithenamelpaintoveracoat Ofanticorrossivepaint.The Colourcoat And Brand Will Be Decided By The Engineer - In - Charge. 23 Earthing With 50 Mm Dia. G.I. Pipe, 3.65 Mm Thick & 3Mtrs Long ( 2 Sets ) Andconn. By 25X 6 Mm G.I. Strip ( For Reqd Length ) Upto The Earth Bus-Clamp With The Equipments On Wall / Floor With Staplesburied Inside As Reqd. At Site And With 25 Mm X 6Mm Gi Flat Strip To Earth Electrode Pipe, Fastening With 13Mmx80mm G.I Bolts, Nuts, Washers, Including All F & F Of Materials & Filling & Restoring The Surface By Ramming &Making Suitable Earthpit With Brick Structure & Ms Lid On Top As Per Direction. 24 Installation Of Above Panel, Main Switch Etc. In The Pump Housse And Actuator Operated Ci Butterfly Valve Including Supply Of 12 Core, 2.5 Sq. Mm. Copper Control Cable, Ci Short Piece, Bend, Compensating Ms Flange, Nuts, Bolts, Gaskets And Other Fixing Materials Required To Complete The Job In All Respect Along With Testing The Installation Upto Entire Satisfaction Of Eic. ( Incl. Supply Of Necessary Spirals’ Reqd For Orientation Of Pipeline ) . 25 Supply And Delivery At Site Of 30 Kva, 3Phase, Oil Cooled Type Servo Motor Operated Copper Wound Line Voltage Corrector Conforming To Is-9815 ( Pt.-1 ) -1994 Suitable For Un-Balanced Input Voltage With Following Specification Including First Filling Oil As Per Is-335 Where Applicable. ( Make : As Per Approved Vendor List. ) ( Details Of Voltage Stabilizer As Per Technical Specification ) 26 Supply And Delivery Of Following Materials 27 100Amp. Re-Wireable Type Tp Main Switch With Neutral Link ( Make: As Per Approved Vendor List. ) . 28 100 Amp. 4 Bar Copperbusbar Chamber Box By 16 Swg Sheet Steel Enclosure Including Porcelain Chair Etc. With Painting Complete As Per Direction Of The Eic. 29 35 Sqmm. 3 ½Core 1.1Kv Grade, Al, Ar. Pvc Insulated Cable ( Make: As Per Approved Vendor List. ) 30 Making Brick Built Foundation With Supplying Of All Required Materials Suitable For The Above Voltage Stabilizer By ( 4:1 ) Cement Mortar Includingholding Down Foundation Bolts ( If Required ) And Plaster With Neat Cement Finish As Per Direction Of E.I.C. 31 Fitting, Fixing And Connection Of Above Supplied Changeover Switch, Bus-Bar And Main Switch On The Wall By Supplying All Necessary Materials To Complete The Job. 32 Installation Of The Above Voltage Stabilizer On The Foundation Including All Connection Complete As Per Direction Of E.I.C. 33 Drawing And Connection Ofcable On Wall And All Connection Complete With All Equipment As Per Requirement And As Per Direction. 34 Making Joints Of The Cable By Supplying Compression Type Gland Thimple, Socket Etc.As Per Requirement And As Per Direction Of Eic. 35 Earthing With 50 Mm Dia. G.I. Pipe, 3.65 Mm Thick & 3Mtrs Long ( 2 Sets ) Andconn. By 25X 6 Mm G.I. Strip ( For Reqd Length ) Upto The Earth Bus-Clamp With The Equipments On Wall / Floor With Staplesburied Inside As Reqd. At Site And With 25 Mm X 6Mm Gi Flat Strip To Earth Electrode Pipe, Fastening With 13Mmx80mm G.I Bolts, Nuts, Washers, Including All F & F Of Materials & Filling & Restoring The Surface By Ramming &Making Suitable Earthpit With Brick Structure & Ms Lid On Top As Per Direction. 36 Supply, Delivery And Storage At Site Of Automatically Controlled Diaphragm Type Chlorinator Dosing Pump With Flow Rate 100 Lph And Maximum Pressure Of 10 Kg / Cm2 With All Accessories For Pump & Motor, Foundation Bolt, Suction And Discharge Flange And With Storage Tank Of Dosing Solution Of 100 Ltr. Capacity And The Prime Mover To Be Coupled With Pump Of 0.5 H.P., 3 Phase, 1450 Rpm, Squirrel Cage Tefc Induction Motor, Motor Will Be Ie3. [ Make Of Machine: As Per Attached Vendor List Of Phed. ] 37 Installation And Commissioning Of The Above Supplied Chlorinator With All Accessories, Pvc Tank And Drawing Of Power Line As Per Ie Rules By Supplying Of Necessary Wire And Continuous Earthing. This Include The Cost Of All Necessary Cc Foundation [ At Least 200Mm Height ] With Concrete Mixture [ Sand, Cement, Stone, Chips ] And Neat Cement Finish By Supplying Of All Required Materials And Testing The Entire Set As Per Direction Of Eic. [ Power Will Be Feed From Plc Panel Of Pumpingmachinery ] 38 Making Internal / External Electrification Of P / House By 2 X1.5 Sq.Mm. P.V.C. Cuwire Through Suitable Size Casing / Capping For 4 Nos. Point ( 1 No. Bracketpoint , 1 No. Tube Light Point , 1 Nos. Bulk Head Point And 1 Fan Point ) And 1No. 5A , 5 Pin Plug Point Withearthingattachment Of1 X 1.5 Sqmm Cu. Wire With Supplying Of Tube Light Fittings ( Make-As Per Approved Vendor List. ) , Fan ( 5* Rating ) , Bulbs As Per Approved Make Including Suppying And Fixing 10 A. Dp Mcb ( As Per Approved Vendor List. ) Make On Wall All Complete As Per I.E. Rules And Direction. ( Including Making External Illumination By Supply & Fixing Of 1 No. 40W Led Ip 66 Type Outdoor Luminairie Incl. Supply & Installation Of Ms Bracket & Connection Complete ) Make : As Per Approved Vendor List. 39 Testing The Entire Installation As Per Satisfaction Of Engineer-In-Charge. 40 Labour Charges For 1 ( One ) No. Operating Person For Operation And Guarding Of Pump / Valve / Disinfection Arrangement With All Accessories. 41 Supervision Charges For Electrical Installation By Licensed Electricians Per Ie Rules 1956 Read With Latest Amendments Overhead Expenditure.
|