Subscribe     Pay Now

Providing Fitting Fixing And Installation Of Fire Fighting System At Newly Constructed Aud...


Contract Award Notice

TRR 9351588
Organization Public Works Department
Tender No 39_EE_DNIeT_MECH_DIV_AGT_22_23
Funded By Self-Funded
Country India , Southern Asia
Contract Value 648,900

Work Detail

Providing Fitting Fixing And Installation Of Fire Fighting System At Newly Constructed Auditorium At Panchayati Raj Training Institute Ad Nagar Agartala Tripura- 1 Providing & Fitting Fixing Of Cylinder Less Automatic Fire Suppression System Blaze Cut 2 M To Be Installed In The Electric Main Penal Board Complete As Per Direction Of The Engineer-In-Charge. 2 Providing & Fitting Fixing Of Co2 Fire Extinguisher 2 Kg Capacity Cylinder ( Isi Mark Is :15683 For Class 13B Typefitted With Pvc Bend Horn Will Be Installed In The Different Places Of The Auditorium Building Complete As Per Direction Of The Engineer-In-Charge. 3 Providing & Fitting Fixing Of Co2 Fire Extinguisher 4.5 Kg Capacity Cylinder ( Isi Mark Is :15683 For Class 21 B Typefitted With Pvc Bend Horn Will Be Instsalled In The Different Places Of The Auditorium Building Complete As Per Direction Of The Engineer-In-Charge 4 Providing & Fitting Fixing Of Abc Powder Type ( Stored Pressure ) Fire Extinguisher 6 Kg Capacity Cylinder ( Isi Mark Is :15683 Fire Rating 3A, 34B Type With Discharge Hose & Nozzle Will Be Installed In The Different Places Of The Auditorium Building Complete As Perdirection Of The Engineer-In-Charge 5 Providing & Fitting Fixing Of Dry Chemical Powder ( Dcp ) Fire Extinguisher 6 Kg Capacity Cylinder ( Isi Mark Is :15683 Fire Rating 34B With Discharge Hose & Nozzle Will Be Installed In The Different Places Of The Auditorium Building Complete As Perdirection Of The Engineer-In-Charge 6 Providing & Fitting Fixing Of Wet Chemical Fire Extinguisher ( K Type ) 6 Ltrs Capacity Cylinder Will Be Installed In The Different Places Of The Auditorium Building Complete As Per Direction Of The Engineer-In -Charge. 7 Providing & Fitting Fixing Of Air Release Valve 25 Mm Gun Metal Body With Suitable Pressure Release Capacity For Down Comer Pipeline Of Fire Fighting System Of The Auditorium Building Terrace Complete As Per Direction Of The Engineer-In-Charge 8 Providing And Fixing First Aid Fire Hose Reel Equipment Confirming To Is : 884-1969 With Upto Date Amendments Finished With Post Office Red Spray Paint And Complete With Following As Required : ( I ) 20Mm Dia 36.5 Meters Long Hose Tubing Of Approved Make Confirming To Is: 5132-1969 With Upto Date Amendments. ( Ii ) Swinging Type Hose Guide Fixing Bracket Assembly ( Iii ) 25Mm Dia Gate Valve ( Iv ) 6Mm Outlet Ss Nozzle With Shut Off Valve As Required 9 Providing And Fixing 63 Mm Dia. 15M Long Reinforced Rubber Lined ( Rrl ) Woven Jacketed Hose Tested To Bursting Pressure 32 Kg / Sqcm Including Gunmetal Male And Female Instantaneoustype Coupling Approved By Fire Authority, Machine Would With G.I Wire Complete In All Respects.Hose Shall Conform To I.S 636 Type Ii And Coupling To I.S 903-1985 With Isi Certification ( Two Per Hydrant Station ) . 10 Providing And Fixing Standard Short Size Ss Branch Pipe With Gunmetal Nozzle 16Mm Dia Outlet With Standard Male Instantaneous Spring Lock Type 63Mm Dia Coupling.Branch Pipe And Nozzle Shall Confirm To Is : 903-1985 11 Supplying , Installation, Of Weather Proof Cabinet Forhose Fabricated From 16 Gauge Ms Sheet Of Fully Welded Construction With Hingeddouble Front Door With Locking Arrangement And Partially Glazed With 4Mm Thick Glass, Stove Enameled Fire Red Finish With Fire Hose Written On Front Suitable To Fit 2 Nos Hose Reel 30 Mtrlength & Short Branch Pipe And Hydrant Outlet.Size 750 X 600 X 250 Mm ( Hxbxd ) Or Suitable To Fit The Items 12 Providing And Fixing Internal Fire Hydrant Comprising Of Ss Fire Hydrant Valve ( Landng Valve ) 80 Mm Inlet With Single Headed With Single Outlet With Control And Fitted With 63Mm Dia Instantaneous Female Coupling On The Outlet Complete With Orifice Flange As Required, Blank Cap And Chain Locations As Per Drawings ( Inlet Flanges To I.S 5290-1977 Class C ) 13 Supply, Erection, Testing And Commissioning Of Terrace Fire Pump Located At Terrace Level Capable Of Delivering Following Capacity Complete With Adequate Hp. Electrical Driven Monoblack Type Centrifugal Pump With Squirrel Cage Motor With Bronze Impellors, Pressure Gauge, Pressure Switch Etc Complete.900 Lpm 30M Head. 14 Slftc Of M.S. Pipes On Surfacesupplying, Laying, Fixing, Testing & Commissioning Of Following Sizes ( Nb ) Of Isi Mark Heavy Class Tata / Jindal M.S Pipes Including Cutting Threading Welding Etc. And Providing All Fittings E.G. Elbows. Reducers. Clamps, Hangers, Flanges, Gaskets. Nuts& Bolts Cost Including Providing Two Coats Of Synthetic Enamel Paints Of Approved Shades Over A Coat Of Primer. Prior To Application To Primer The Surface Should Be Clean For Any Dirt, Rusts, Rough Substance Etc. Including Painting Of Legends Of Both Direction Arrow As Per Approval Of The Project Manager. 15 150 Mm Dia. 4.6 Mm Thickness. 16 100 Mm Dia. 4.6 Mm Thickness. 17 80 Mm Dia 18 50 Mm Dia. 19 Slftc Of M.S. Pipes Under Groundsupplying, Laying, Fixing, Testing & Commissioning Of Following Sizes ( Nb ) Of Isi Mark Heavy Class Tata / Jindal M.S Pipes Including Cutting Threading Welding Etc. And Providing All Fittings E.G. Elbows. Reducers. Clamps, Hangers, Flanges, Gaskets. Nuts& Bolts, Washer Etc. Including Excavation Of All Kind Of Soil, Refilling, Ramming, Shoring, Removing The Excavated Surplus Material, Providing Adequate Support To The Pipe And Making Good The Same Complete As Required. Rate Shall Included For Dewatering Necessary Ti Execute The Work. The Pipe Shall Not Be Less Than 1.0 Mtr. Below Ground Level At Any Point. Protection Of Embedded Ms Pipes And Fittings By Applying Pyp Kote Primer ( @ 100 Gm / Sqm ) , Thereafter Wrapping, 04 Mm Thick Pyp Kote ( Aw 4 Mm ) Protection Coating By Thermo Fusion Process. Overlap Shall Be Maintained At 15 Mm. The Application Process Shall Be Strictly Accordingly To ManufacturerS Specification.150 Mm Dia. 20 Providing And Fixing Butterfly Valve Confirming To Type P.N. 1.6 Of Is 13095-1991 Complete With Flanges, Bolts, Nuts, Gasket Etc. As Per Specifications Complete In All Respect Hydraulically Tested To 20Kg / Sq Cm. 21 80 Mm Dia. 22 100 Mm Dia. 23 Providing And Fixing Dial Type Pressure Gauge With Isolation Cock And Pipe At Hydrant Stationdial Diameter 150Mm Calibration 0-15Kg 24 Providing And Fixing Gunmetal Collecting Head With 63 Mm Dia. Instantaneous Typeinlet And 150 Mm Dia. Flanged Outlet With Built-In Check Valve For Fire Brigadeconnection To Down Comer Or Underground Tanks And Wet Risers ( If Exist In The System ) ( I.S 904 ) Including Necessary Supports Complete In All Respects As Per Standard Design.Four Way.

Key Dates

Contract Date 21 Nov 2022

Contact Information

Company Name
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 91007 ARB Consultancy INR 648900.00
Contract Value 648,900
Contract Date 21 Nov 2022

View Notice Now...

Login with your Social Account for Instant Access to this notice


Tell us about your Product / Services,
We will Find Tenders for you