Supply,Installation, Testing, Commissioning, Training, Operation And Maintenance Of Scada Based Automatic Operation Of Barrage At Ropar Head Works And Scada Based Automatic Operation Of Sirhind Canal System Supply,Installation, Testing, Commissioning, Training, Operation And Maintenance Of Scada Based Automatic Operation Of Barrage At Ropar Head Works And Scada Based Automatic Operation Of Sirhind Canal System , Part -A Supply , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Level /Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast/ Cantilever As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc/Rtu / Datalogger As Per Technical Specifications. , Supply, Installation, Testing And Commissioning Of Side Looking Acoustic Doppler Based Velocity Meter (Advm) For Direct Downstream Discharge Measurement In Head /Cross Regulators Ofcanal System With Bed Width 20-120M As Per The Site Required,Including Integration With Plc/Rtu/Datalogger,Including Retractable Mounting Frame, Cabling,Complete As Per Technical Specifications. , Supply, Installation, Testing And Commissioning Of Side Looking Acoustic Doppler Based Velocity Meter (Advm) For Direct Downstream Discharge Measurement In Head /Cross Regulators Ofcanal System With Bed Width 0-20M As Per The Site Required,Including Integration With Plc/Rtu/Datalogger,Including Retractable Mounting Frame, Cabling,Complete As Per Technical Specifications. , Supply Of Remote Plc/Rtu System With Software Development Of Plc/Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc/Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Ofbullet Camera(Fixed Type)-Ip Digital Night Vision(I.R) Out Door Weather Resistant, 2 Mega Pixel 2 Or4 With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array/ 72 Led Colour Camera. 6 Or 8 Or 12Mm (According To Site Suitability) 3Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Ropar Barragecomplete As Per Technical Specifications. , Supply Of Pan Tilt Zoom (Ptz) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based (Digital) Camera, 500 Mtrs. Night Vision (Multiple Intelligent Array System) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Barrage & Cross Regulator Monitoring. As Per Technical Specifications. , Supply Of Automatic Water Level Recorder( Non-Contact Radar Type) For Rivers/Canals/Reservoirs Having 35M Range With All Necessary Hardware As Per Technical Specifications. , Supply Of Datalogger 2 Analogue Channels Type With Gsm & Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc/Rtu/Datalogger As Per Technical Specifications. , Supply & Erection Of Pre-Fabricated Cabin (Size 6X6 And 8 Height) With Civil Foundation M.S. Angle 50X50x5, Wall Ofsteel-E.P.S.–Steelcompositepanelof.5Mmthickgisheetopening Door, Roof And Floor, Painting Etc. Complete As Per Technical Specification. , Development Of Rating Curve/Stage Discharge Curve As Per Is 15119(Part1&2) And Is 15847 At A River Site/Location(Continuous Activity For 4 Years And Rating Curve Shall Be Revised/Updated Annually Using Departmental Adcp (Operation And Maintenance Cost Of Adcp To Be Borne By Agency) , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply (Smps), 12” Display & Interconnection With Related Remote Plc/Rtu’S, Complete As Per Technical Specification. , Supply Of Customized Irrigation Monitoring Software Which Shall Include Scada Software For Real Time Monitoring & Controlling Of Canal Operations, Water Scheduling, Real Time Data Logging For Complete Canal System With Life Time Licensed Version. As Per Technical Specifications. , Supply Of Master Gradeserver Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232/Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete Forcanal System, As Per Technical Specifications. , Network Video Recorder (Nvr) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd. Along With Dedicated Server With Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With Monitor, And Necessary Accessories,42 Inch Led Display ,4G/3G Dongles/Broadband, Installed With Client Scada Software Including 1 Kva Ups For Power Back Up And A4 Size Colour Printer As Per Technical Specifications At Division Monitoring Station With Necessary Accessories , Supply Of Laptops & 4G/3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Barrage Automation As Per Technical Specifications , Supply Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications. , Supply Of 110” Smart Led Display System For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room. , Part B- Installation , Installation, Testing And Commissioning Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measurement Of Upstream Level/Downstream Discharge In Canal Across Head / Cross Regulators. Including All Necessary Mast/ Cantilever Associated Civil Works Cabling, Conduits And Electrical Fitting Complete As Per Technical Specification. , Installation, Testing And Commissioning Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc/Rtu/Datalogger As Per Technical Specifications. , Installation, Testing And Commissioning Of Remote Plc/Rtu System With Software Development Of Plc/Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc/Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing And Commissioning & Integration With Nvr Located At Barrage Control Room Of Bullet Camera(Fixed Type) Ip Digital Night Vision(I.R) Out Door Weather Resistant, 2 Mega Pixel 2 Or4 With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array/ 72 Led Colour Camera. 6 Or 8 Or 12Mm (According To Site Suitability) 3Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Ropar Barrage Completeas Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom Camera, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip (Digital) Camera, 500 Mtrs. Night Vision (Multiple Intelligent Array System) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Barrage Monitoring , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measuring Upstream Level & Downstream Discharge Of Barrage. Including All Necessary Cabling, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing And Commissioning Of Datalogger2 Analogue Channels With Gsm And Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of (5M*5M)*2M Along With Lockable Gates For External Protection Of Sensors And Dcp At Rtdas Station As Per Technical Specification , Installation, Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc/Rtu/Datalogger As Per Technical Specifications. , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply (Smps) ,12” Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc/Rtu’S, As Per Technical Specification. , Installaton Of Customized Irrigation Monitoring Software Which Shall Include Scada Software For Real Time Monitoring & Controlling Of Canal Operations, Water Scheduling, Real Time Data Logging For Complete Canal System With Life Time Licensed Version, As Per Technical Specifications. , Installation, Testing And Commissioning Of Master Server Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232/Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete For Canal System, As Per Technical Specifications. , Installation, Testing & Commissioning Of Network Video Recorder (Nvr) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Server With Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation Testing & Commissioning Of Industrial Grade Computer Node As Workstation Along With Monitor, And Necessary Accessories,42 Inch Led Display ,4G/3G Dongles/Broadband, Installed With Client Scada Software Including 1 Kva Ups For Power Back Up And A4 Size Colour Printer As Per Technical Specifications At Division Monitoring Station With Necessary Accessories , Installation, Testing And Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Scada Control Room Equipment’S As Per The Technical Specifications. , Installation, Testing And Commissioning Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Colour Printer At Scada Control Room As Per Technical Specifications. , Installation, Testing And Commissioning Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing Atcanal Scada Control Room. , Installation, Testing And Commissioning Of 110” Smart Led Display System For Monitoring Of Canal System At Scada Control Room, As Per Technical Specifications. , Charges Of High-Speed Synchronous Internet Connection (Min. 8 Mbps Upload And Download Speed) And Static Ip Forcanal System For Five Years. , Charges For High Speed 4G/3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of System And 7 Division Monitoring Stations For Five Years , Five Years Operation & Maintenance And Comprehensive Warranty For Scada Based Canal Monitoring & Controlling System With Telemetry Along With Accessories, Installed At Designated Locations Within Canal System After Final Acceptance Of The Scada Systems. This Includes Replaceme+B20nt Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gsm & Gprs (Sim & Internet Charges) Telemetry For Data Transmission Shall Be Borne By Bidder. Minimum One Service Engineer Shall Be Placed At Canal Scada Control Room For Operation Of Canal Monitoring & Controlling System With Telemetry For Entire Warranty Period Of 5 Years.
|