Subscribe     Pay Now

Repair / Maintenance Of High Tension Distribution System And Ht Equipments At Kanheri H...


Contract Award Notice

TRR 9186897
Organization Military Engineer Services
Tender No 82628/E8
Funded By Self-Funded
Country India , Southern Asia
Contract Value 3 Million

Work Detail

Repair / Maintenance Of High Tension Distribution System And Ht Equipments At Kanheri Hills And Hill Top At Site K Hills Site R And Site P Under Ge Airforce Thane-M&L For Calibration All Measuring Meter With, Servecing All Mechanical Parts, Replace The All Electric Wiring Of Panel, Decarbonizing All Ht Contact Point Testinght 22Kv Vertical Draw Out Type Vcb Of Repturing Capacity 250 Mva, 250 Ampsincluding Replacement Of Unserviceable Spare Parts And Adjustment Of Over Current Relay, Earth Fault Relay, Checking Of Vaccum Of Interrupter, Including Connected Accssories Cleaning Offixed And Moving Contacts, Testing Of Electrical Wiring System, Ammeter, Voltmete , Vaf Meter, Selector Switch All Illuminated Indicationes For R, Y, B, Pahse, By Qualified Technical Person From Oem, Complete All As Specified And Directed By Engr-In- Charge.Note:- Necessary Spare Parts, Need To Replace Will Be Paid In Respective Item. 2 M&L For Calibration All Measuring Meter With, Servicing All Mechanical Parts, Replace The All Electric Wiring Of Panel, Decarburizing All Ht Contact Point Testinght 11Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Ampsincluding Replacement Of Unserviceable Spare Parts And Adjustment Of Over Current Relay, Earth Fault Relay, Checking Of Vacuum Of Interrupter, Including Connected Accessories Cleaning Offixed And Moving Contacts, Testing Of Electrical Wiring System, Ammeter, Voltmeter , Vaf Meter, Selector Switch All Illuminated Indications For R Y B Phase, Including High Voltage Test, Primary Injection Test, Relay Testingby Qualified Technical Person From Oem, Complete All As Specified And Directed By Engr-In- Charge.Note:- ( A ) Necessary Spare Parts, Need To Replace Will Be Paid In Respective Item ) 3 M&L For Indicator Led Lamp, Red, Yellow And Orange 110 V, Ac, For Ht 22 Kv Vcbcomplete All As Specified And Directed By Engr-In- Charge. 4 Supply Closing Coil, 110 V, Dc For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And Directed By Engr-In- Charge. 5 Supply Shunt Release Coil On, 110 V, Dc, Suitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 6 Supply Shunt Release Off, 110 V , Dc, Suitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 7 Supplycontrol Fuse, Hrc, 2 / 4 / 6 Amp For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 8 Supply Motor Cut Off Switch For Servicing / Repairing The Ht 22 Kv Vcbcomplete All As Specified And As Directed By The Engr- In- Charge. 9 Supply Ht Tape For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 10 Supplymonoplast Tape For Servicing / Repairing The Ht 22 Kv Vcbcomplete All As Specified And As Directed By The Engr- In- Charge 11 Supply Digital Volt Meter 96X96mm, 0-500V, Aux Supply 110V, Ac, Suitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 12 Supply Digital Ammetersuitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 13 Supply Auxiliary Switch On Block Magnet For Servicing / Repairing The Ht 22Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 14 Supply Male & Female Spout Assembly For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 15 Supplyct Of Ratio 50 / 5 A For Vcb Suitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 16 Supplyover Current Really Suitablefor Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 17 Supply Master Trip Relay Suitable For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 18 Supply Digital Vaf Meter , Em 6400Suitable For Ht 22 Kv Vcb For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 19 Supply Contact Arm Assembly For Ht 22 Kv Vcb For Servicing / Repairing The Ht 22 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge 20 Supply Closing Coil, 110V, Dc For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 21 Supply Shunt Release On, 110V, Dc For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 22 Supply Shunt Release Off, 110V, Dcfor Servecing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 23 Supply Motor Cut Off Switch For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 24 Supply Auxiliary Switch On Block Magnetfor Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 25 Supply Male & Female Spout Assembly For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 26 Supply Ct Of Ratio 30 / 5 A For Vcbfor Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 27 Supply Relay Assembly ( Current, Voltage ) Suitable For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 28 Supply Master Trip Relay Suitable For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 29 Supply Contact Arm Assembly For Servicing / Repairing The Ht 11 Kv Vcb Complete All As Specified And As Directed By The Engr- In- Charge. 30 M&L Forservicing / Testingofpower Transformer11 / 22 / 0.44 Kv Up To Capacity 400Kva ( A ) Ir Value Of Winding. ( B ) De Carbonizing The Cable Terminal Of The Transformer. ( C ) Earth Resistance Checking. ( D ) Replacement Of Silica Gel 31 Dehydration / Filtration Of Transformer Oil By Means Of Centrifugal Filtration Plant To Achieve The Specified Dielectric Strength Of 35 To 40 Kv At 2.5 Mm Gap In Existing Position Of Transformer / Servo Stabilizer Of Any Capacity And Transformer Oil For Topping Up At Various Sub Station Complete All As Specifiedand Directed By Engg-In-Chargenote: Transformer Oil Used For Top Up Measured And Paid Separately. 32 Supply And Pouringof New Transformer Oil To Achieve A Di-Electric Strength Up To 60 Kv In 4 Mm Gap Conform To Is-335-1983 With Sealed Barrel Contains Each 210 Litre 33 Disconnection The Ht Termination, Supply And Fixing Ht Boot Cover At Cable End And Vcb / Rmu Complete All As Specifiedand Directed By Engg-In-Charge 34 Disconnecting All In Coming And Outgoing Cables, Removing The Transformer / Servo Stabilizer From The Platform / Two Pole Structure / Floor And Loading It In The Vehicle Carefully Using Crane And Transporting It To The ContractorS Workshop, Carry Out The Required Repairs And Transport The Transformer Back To The Site , Install It, Reconnect All The Incoming And Out Going Cables By Properly Crimping Using Lugs Of Suitable Sizetaping Thebushes / Bus Bars, Using Insulation Tape And Testing Completeof Capacity 160 Kva To 400 Kva All As Directed .Note:- Gasket Set, Lt / Ht Side Ceramic Bushing, Spindle For Ht / Lt Side , Rewinding, Dehydration Of Oil Shall Be Measured And Paid Separately In Respective Items. 35 M&L For Taking Out Unserviceable Winding & Supply And Winding Of22 / 0.433 Kv Hv Coils, Using New Copper Wire / Strip Of Proper Size Including Insulating Materials ( Double Insulation ) As Per Existingsize Of Core Of Transformer Capacity 160-400 Kva Complete Including Heating , Varnishing Complete All As Specifiedand Directed By Engg-In-Charge 36 M&L For Taking Out Unserviceable Winding Supply And Winding Of22 / 0.433 Kv Lv Coils, Using New Copper Wire / Strip Of Proper Size Including Insulating Materials ( Double Insulation ) As Per Existingsize Of Core Of Transformer Complete Incl Heating , Varnishing Complete All As Specifiedand Directed By Engg-In-Charge 37 Supply Only Breather Assembly Of Approved Make Filled With Silica Gel Suitable For Transformer Ofcapacityupto 400 Kva Volt Distribution Transformer Complete All As Specifiedand Directed By Engg-In-Charge 38 Supply Only Brass Spindle For Terminal On Ht Side Threaded Complete With Nut Washers Etc Of Suitable Dia For Transformer Of Capacity 160 To 400 Kva Complete All As Specifiedand Directed By Engg-In-Charge 39 Supply Only Brass Spindle For Terminal On Lt Side Threaded Complete With Nut, Washers Etc Of Suitable Dia For Transformer Ofcapaicty 160 To 400 Kva Complete All As Specifiedand Directed By Engg-In-Charge 40 Supply And Fix Ceramic Bushing And Gasket On Lt Side Of Transformer Of Capacity 160 To 400 Kva 22000 / 433 Volt Distribution Transformer Complete All As Specifiedand Directed By Engg-In-Charge 41 S & Fceramic Hv Bushing With Gun Metal Bushing Stud, Nuts And Washers For Transformerof Capacities 22000 / 433 Volt Distribution Transformer Complete All As Specifiedand Directed By Engg-In-Charge 42 Supply And Fixing In Replacement Of Complete Gasket ( Cork Sheet ) 6 Mm Thick Complete Of Capacity Of 160 Kva To 250 Kvatransformer Including Conical Rubber Bush Complete All As Specifiedand Directed By Engg-In-Charge 43 Disconnecting All Incoming And Outgoingconnection Of Ht11 / 22 Kv Underground Cable, Detecting Faultby Applying Surge Current 1.5 Times The Rated Current& Finding Exact Location Of Fault With Picco Equipmentand Repair The Same Immediately All As Directed. Note:- ( A ) Necessary Jointing Kit To Be Measure And Paid Cables. Complete All As Specifiedand Directed By Engg-In-Charge 44 Supplying, Jointing And Commissioningoutdoor Type Cable End Termination Jointing Kit Heat Shrinkable Type Suitable For Underground Xlpe Cable Size 3 Core 95 To 120 Sqmm 11 / 22 Kv Ht Cablecomplete All As Specifiedand Directed By Engg-In-Charge 45 Supplying, Jointing And Commissioningindoor Type Cable End Termination Jointing Kit Heat Shrinkable Type Suitable For Under Ground Xlpe Cable Size 3 Core 95 To 120 Sqmm 11 / 22 Kv Ht Cable Complete All As Specifiedand Directed By Engg-In-Charge 46 Supplying, Jointing And Commissioningstraight Through Type Cable End Termination Jointing Kit Heat Shrinkable Type Suitable For Underground Xlpe Cable Size 3 Core 95 Sqmm 11 / 22 Kv Ht Cable Complete All As Specifiedand Directed By Engg-In-Charge . 47 Taking Up Unserviceable Ht 22 Kv Underground Cable For Repair, Replace The Damage Portion Complete All As Specifiedand Directed By Engg-In-Charge 48 Supply And Laying, Testing And Commissioningh.T. Under Ground Armored Pvc Insulated And Pvc Sheathed Heavy Duty 22000 Volts Grade Underground Cable Of Size 3 Core, 95 Sq Mm Complete All As Specifiedand Directed By Engg-In-Charge 49 Supply And Laying, Testing And Commissioningh.T. Under Ground Armored Pvc Insulated And Pvc Sheathed Heavy Duty 11000 Volts Grade Underground Cable Of Size 3 Core, 120 Sq Mm Complete All As Specifiedand Directed By Engg-In-Charge 50 Relaying The Serviceable Ht Cable, After Necessary Testing In Ground, Floor In Same Trench Ornew Route Complete All As Specifiedand Directed By Engg-In-Charge 51 Supply And Fix Gi Pipe 100 Mm Dia Light Grade Complete With All Fitting For Supporting Cable On Four Pole Structure Complete All As Specifiedand Directed By Engg-In-Charge 52 Excavation In Trenches Not Exc 1.5 M In Depth And Not Exc 1.5 M Wide For Taking Out / Laying Cable And Getting Out In Hard / Dense Soil Complete All As Specifiedand Directed By Engg-In-Charge 53 Removing Excavation Soil At A Distance Not Exc 50 M And Deposited Where Diverted Complete All As Specifiedand Directed By Engg-In-Charge 54 Returning, Filling In Including Spreading, Leveling, Watering And Well Rumming In Layers Not Exc 25 Cm Complete All As Specifiedand Directed By Engg-In-Charge 55 Sand Cushioningfor Cable Protection By Spreading In Trenches Crushed Stone Sand By Gently Punning Down Manually Complete All As Specifiedand Directed By Engg-In-Charge.Note:- Punnned Thickness Shall Only Be Measured And Paid. 56 Supply And Laying Un Reinforced Precast Concrete Cable Cover Class Ehv, Type-I, Flat Size 300 Mmx 180 Mm X 40 Mm Laid In Trenches Complete All As Specifiedand Directed By Engg-In-Charge. 57 Re- Laying Un Reinforced Precast Concrete Cable Cover Class Ht, Type-I, Flat Size 300 Mmx 180 Mm X 40 Mm Laid In Trenches Complete All As Specifiedand Directed By Engg-In-Charge. 58 Supply And Cross Arm, Bracing, Supports, Clamps And Back Plate Fabricated From Structural Steel Section Including Nuts, Bolts, Washers, Welding, Bending, Drillingholes For Bolts In Any Shape And Any Size Inclusive Of One Primer Coat, Two Coats Of Aluminium Paints As Indicateed Complete All As Specified And As Directed By Engineer In Charge 59 Dismelting The Unserviceable Broken Gi Strip Of Any Size As Available At Site, Supply And Fixing Cupper Strip Of Size 32X6mm For Connection From Ht Equiptment To Earth Pit . ( Necessery Connection To Be Made Through Brezing And Brass Nuts And Bolt ) Complete All As Specifiedand Directed By Engg-In-Charge 60 M&L For Shutter Assembly Suitable Forht 22Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Ampscomplete With Mechanism Complete All As Specifiedand Directed By Engg-In-Charge 61 M&L For Pt 22 Kv / 110Vsuitable Forht 22Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Amps For Metering Purpose Complete All As Specifiedand Directed By Engg-In-Charge 62 M&L For Breaker Bus Bar Arm Long With Female Contact Suitable Forht 22Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Amps Complete All As Specifiedand Directed By Engg-In-Charge 63 M&L For Pp Tubes Suitable Forht 22Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Amps Along With Necessary Accessories Complete All As Specifiedand Directed By Engg-In-Charge 64 M&L For Phase Barrier Along With Necessary Accessories Suitable For Ht 22Kv Vertical Draw Out Type Vcb Of Rupturing Capacity 250 Mva, 250 Amps Complete All As Specifiedand Directed By Engg-In-Charge 65 M&L For Heater And Thermostat Suitable For Ht 22Kv Vertical Draw Out Type Vcb Of Repturing Capacity 250 Mva, 250 Ampscomplete All As Specifiedand Directed By Engg-In-Charge 66 M&L For Bushing Spout Panel Ht 22Kv Vertical Draw Out Type Vcb Of Repturing Capacity 250 Mva, 250 Ampscomplete All As Specifiedand Directed By Engg-In-Charge 67 M&L For Tnc Switch Suitable For Ht 22Kv Vertical Draw Out Type Vcb Of Repturing Capacity 250 Mva, 250 Ampscomplete All As Specifiedand Directed By Engg-In-Charge 68 S&F In Replacement Single Phase Smps Based Battery Backed Power Pack For Supply Back-Up For Trip Coil, Protection Relay, Indication, & Other Load In Ht Panels, Working Input Voltage 90 To 300 Volt Ac, Output 110 Volts Dc With Backup For 15-20 Min, Complete All As Specifiedand Directed By Engg-In-Charge 69 M&L For Painting Of Transformer Foundation With Two Coats Of Obd After Complete Scrapping Of Old Paint / Whitewash And Making Good Surface Complete All As Specifiedand Directed By Engg-In-Charge 70 M&L For Ht 22 Kv Sleeve For Repairing Vcb 22 Kv Complete All As Specifiedand Directed By Engg-In-Charge 71 M&L For End Terminal Cable Jointing Kit For 22 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit Complete All As Specifiedand Directed By Engg-In-Charge 72 M&L For End Terminal Cable Jointing Kit For 22 Kv ( Earthed ) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit Complete All As Specifiedand Directed By Engg-In-Charge 73 M&L For Cable Jointing Kit For 22 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit Complete All As Specified & As Directed. 74 Dehydration And Filtration Of Transformer Oil Filled In Transformer Installed At Different Locations, Testing Of Oil After Dehydration To Achieve Dielectric Strength Not Less Than 40 Kv For 1 Minute In 2.5 Mm Electrode Gap As Per Relevant Is And To Bring The Acidity With The Permissible Limit Complete All As Specifiedand Directed By Engg-In-Charge 75 Supply & Fixing In Replacement Of Ceramic Hv Bushing With Gun Metal Bushing Stud, Nuts And Washers For Transformerof Capacities 165 / 250 Kva Complete All As Specifiedand Directed By Engg-In-Charge 76 Supply & Fixing In Replacement Of Ceramic Lv Bushing With Bushing Stud ( Brass Metal ) , Nuts And Washers For Transformerofcapacities 165 / 250 Kva Complete All As Specifiedand Directed By Engg-In-Charge 77 Supply And Filling Fresh Tansformer Oil Confiming To Is 335 Having Die Electric Strenght Up To 50 Kv With Oil Testing Kit 2 Mm Thick Top Up Transformercomplete All As Specified And As Directed By Engr In Charge. 78 Disconnecting Of Incoming & Outgoing Cable From Both Side Of Transformer Indoor / Outdoor Type Including All Accessories, Loading Unloading And Transportation From Site To Work Shop As Per Site Requirement And Back To Site After Carried Out Repairs & Assembling , Including Connection For The Capacity 160 Kva To 250 Kva And Commissioning And Testing Complete All As Specified And Directed By Engr In Charge.Note: Gasket Set, Lt / Ht Side Ceramic Bushing, Spindle For Ht / Lt Side, Rewinding , Dehydration Of Oil Shall Be Measured And Paid Separately In Respective Items. 79 Taking Out Defective Ht Winding And M& L For Rewinding Of Ht Coil With Super Enameled Best Quality Copper Wire Of Existing Gauge With Superior Quality Insulation Material For Transformer Of Capacity 160 To 250 Kva Complete All As Specified And Directed By Engr In Charge. 80 M& L For Rewinding Of Lt Coil With Super Enameled Best Quality Copper Wire Of Existing Gauge With Superior Quality Insulation Material For Transformer Of Capacity 160 To 250 Kva Complete All As Specified And Directed By Engr In Charge. 81 Assembling Of Hv And Lv Coils Including Necessaryinsulation With Paperboards And Varnishing, Making Internal Connections, Drying, Removal Of Moisture From Core And Coils, Heating The Complete And Carried Out All Necessary Tests For Transformer Capacity 160 Kva To 250 Kva Complete All As Specified And Directed By Engr In Charge. 82 M& L For Improvement Of Insulation Resistance Value For Core & Coil Winding By Cleaning Complete, Applying Varnishing & Necessary Insulation Material And Baking In Oven Terminal Connection Inside The Transformer Complete All As Specified And Directed By Engr In Charge. 83 Disconnecting The Ht Termination, Supply And Fixing Ht Boot Cover At Cable End And Vcb Complete All As Specifiedand Directed By Engg-In-Charge 84 Disconnecting All Incoming And Outgoing Connection Of Ht 22Kv Under Ground Cable, Detecting Fault By Applying Surge Current 1.5 Times The Rated Current & Finding Exact Location Of Fault With Pico Equipment And Repair The Same Immediately Complete All As Specified And As Directed By The Eng.In.Charge.Note: Necessary Jointing Kit To Be Measured And Paid Separately In Respective Items. 85 M&L For Servicing / Testing The Following Equipment Of Distribution Transformer 22 / 0.44Kv: ( A ) Ir Value Of Winding ( B ) De Carbonizing All Cable Connection. ( C ) Earth Resistance Checking ( D ) Replacement Of Silica Gel Complete All As Specifiedand Directed By Engg-In-Charge 86 Painting Of Transformer After Cleaning The Body Surface Of Transformer By Rubbing With Emery Paper To Remove Oil Stains, Dust Etc And Applying One Coat Of Synthetic Enamel Paint By Spray Paint Incl Writing Sm No. / Mes No. Of Capacity 160 / 250 Kva Transformer Completeall As Specified And Directed By Eng.In.Charge. 87 Supply Onlyassembly Of Approved Make Filled With Silica Gel Suitable For Transformer Of Capacity 160 / 250 Kvadistribution Transformer Complete All As Specified And As Directed By Eng.In.Charge. 88 Supply And Fix Brass Spindle For Terminal On Ht Side Threaded Complete With Nut, Washer Etc Of Suitable Dia For Transformer Of Capacity 160Kva To 250Kva Complete All As Specified And Directed By Engg.In.Charge. 89 Supply And Fix Brass Spindle For Terminal On Lt Side Threaded Complete With Nut, Washer Etc Of Suitable Dia For Transformer Of Capacity 160Kva To 250Kva Complete All As Specified And Directed By Engg.In.Charge. 90 Supply And Fix Ceramic Bushing And Gasket On Lt Side Of Transformer Of Capacity 160 To 250 Kva 22000 / 433 Volt Distribution Transformer Complete All As Specifiedand Directed By Engg-In-Charge 91 Supply And Fixing In Replacement Of Complete Gasket ( Cork Sheet ) 6Mm Thick With And Incl Conical Rubber Bush Complete All As Specifiedand Directed By Engg-In-Charge 92 M&L Forservicing / Testinght 22Kv Vcb Panel Rupturing Capacity 26 / 3 Mva, 1250 Amps Including Calibration, Decarburizing , Troubleshooting, Repairing, Replacement Of Unserviceable Spare Parts And Adjustment Of Over Current Relay, Earth Fault Relay, Checking Of Vaccum Of Interrupter, Including Connected Accssories Cleaning Offixed And Moving Contacts, Testing Of Electrical Wiring System, Ammeter, Voltmeter , Vaf Meter, Selector Switch All Illuminated Indications For R Y B Phase, By Qualified Technical Personcomplete All As Specified And By The Engr- In- Charge.Note:-Necessary Spare Parts, Need To Replace Will Be Paid In Respective Item. 93 Supply Only Voltage Indicator Lamp ( Red, Yellow And Orange ) 220 V, Ac For Servecing / Replacement The Ht 22Kv Vcb Complete All As Specified And Directed By Engg.In.Charge. 94 Supply Only Control Fuse, Hrc, 2 / 4 / 6 Amp For Servecing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 95 Supply Only Ht Tape For Servecing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge 96 Supply Only Monoplast Tape For Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 97 Supply Only High Voltageover Current Protection Relay For Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 98 Supply Only Earth Fault Relay For Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 99 Supply Only Auxillary Contacts For Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 100 Supply Only Space Heater Alongwith Thermostat For Ht Vcb Panel Including Electric Connection Complete All As Specified And Directed By Engg.In.Charge. 101 Supply Only Master Trip Relay Suitable For Ht 22 Kv Vcb Panel Complete All As Specified And Directed By Engineer-In-Chrage. 102 Supply Only Contact Arm Suitable For Ht 22 Kv Vcb Panel Complete All As Specified And Directed By Engineer-In-Chrage. 103 Supply Only Shunt Release Coil On, 110 V, Dc Suitable For Ht 22 Kv Vcb Panel Complete All As Specified And Directed By Engineer-In-Chrage. 104 Supply Only Shunt Release Coil Off, 110 V, Dc Suitable For Ht 22 Kv Vcb Panel Complete All As Specified And Directed By Engineer-In-Chrage. 105 Supply Only Key Locksfor Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 106 Supply Only Switch Operating Assembly Servicing / Repairing The Ht 22Kv Vcbcomplete All As Specified And Directed By Engg.In.Charge. 107 M&L For Shutter Assembly Suitable For Ht 22 Kv Vertical Draw Type Vcb Complete All As Specified And Directed By Engr-In-Charge. 108 M&L For Taking Down Carefully Existing Serviceable Switch Air Break, Gang Operated Outdoor, Any Type Of Capacity Upto 22 Kv, Servicing To The Operating Mechanism, Greasing Etc Of All Joints For Smooth Operation, With & Including Replacement Of Burnt Male / Female Contact Where Required, Re-Fixing The Switch Air Break, Gang Operated Outdoor, Testing, Complete All As Specified And As Directed. 109 Taking Down Unserviceable God Of Any Capacity And Supply And Installation Ht 22Kv / 200Amps Outdoor Type God Including Dropout Fuse Assembly Complete All Required At Site Etc Complete All As Specifed And Directed By Engineer In Charge. 110 Supply & Fixing Dropout Fuse 23 Swgcomplete All As Specified And Directed By Engg.In.Charge. 111 S&F In Replacement Copper Stripof Size 32X 6Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground Complete All As Specified And Directed By Engg.In.Charge 112 S&F Copper Stripof Size 20X 3.15 Mm With Saddles And Fixing Screws Etc. For Roof Conductors And Down Conductors Above Ground Complete All As Specified And Directed By Engg.In.Charge 113 S&F In Replacement Single Phase Smps Based Battery Backed Power Pack For Supply Back-Up For Trip Coil, Protection Relay, Indication, & Other Load In Ht Panels, Working Input Voltage 90 To 300 Volt Ac, Output 110 Volts Dc With Backup For 15-20 Min, Complete All As Specifiedand Directed By Engg-In-Charge 114 S&F Lightning Arresters Ht 22 Kv 65 Kilo Amp Non Linear Expulsion Type Transmission Class With Standard Fittings Confirming To Is-3070 ( Part-I ) 1985, Including Dismantling & Taking Down Old Unserviceable Lightning Arresters, Complete All As Specifiedand Directed By Engg-In-Charge 115 S&F Disc Type Insulator, Porcelain, Vitreous, 145Mm High And 255Mm Dia Ball And Socket Type, White, Brown Or Green, Single Disc Assembly For Tension With Tension Clamps For Conductors, Working Pressure 22000 Volts, Including Dismantling & Taking Down Old Unserviceable Insulator, Complete All As Specifiedand Directed By Engg-In-Charge 116 Supply & Laying Xlpe Insulated , Screened, Pvc Bedded, Galvanizedsteel Strip Or Wire Armoured Heavy Duty Electric Power Cable With Aluminum Conductor, 22000 V Grade, Cross Sectional Area Of3 Core 95 Sqmm In Trenchescomplete All As Specifiedand Directed By Engg-In-Charge 117 Supply & Laying Un Reinforced Precast Cement Concrete Cable Cover Class Hv Type 1, Flat, Size 300Mm X 180Mm X 40Mm Complete All As Specifiedand Directed By Engg-In-Charge 118 M&L For Earthing Complete With Copper Earth Plate Electrode 600X 600X 3 Mm Buried Directly In Ground With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Gound Level And Connected To Earth Test Point By Means Of Copper Strip Of Size 20X3 Mm All As Specified And Shown In Electric Plate No 3 Of Mes Ssr Part-I 2009 Including Earthwork, Pcc Chamber, Ci Cover, Protection And Watering Pipe, Funnel, Mesh Etc All As Required At Site And Complete All As Specifiedand Directed By Engg-In-Charge.Note: ( I ) . 7.5 Rm Copper Strip In Deemed To Be Included In Quoted Rates Beyond 7.5 Rm Strip Shall Be Measured And Paid Separately. ( Ii ) . Earth Resistance Of Earth Pit Should Be Less Than 2 Ohms. On Testing After Completion If The Desired Earth Resistance Is Not Obtained The Earthing Will Be Redone At No Extra Cost. ( Iii ) Rate Quoted By The Tenderer Is Deemed To Include Salt & Charcoal Upto & Above 450 Mm Top Of Copper Plate. ( Iv ) Soil Registance Test If Required Shall Be The Responsbility Of Contractor Without Any Extra Cost. 119 Excavation In Trenches , N Exc 1.5 M Wide And N, Exc 1.5 M In Depth For Foundation, Etc. Or For Shafts, Wells Cesspits, Manholes, Peir Holes. Etc 1.5 M N Exc 10 Sqm On Plan And N Exc, 1.5 M In Depth And Getting Outcomplete All As Specifiedand Directed By Engg-In-Charge 120 Returning, Filling Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exc 25Cm In Soft / Soil Complete All As Specifiedand Directed By Engg-In-Charge 121 Removing Excavated Soil Not Exc 50M Depositing Where Directed At A Level Not Exc 1.5M Above The Starting Point Complete All As Specifiedand Directed By Engg-In-Charge 122 M&L Sand Cushioning For Ug Cable Protection / Ducts, Consolidated Sand Compacted With Clean Dry Sand Complete All As Specifiedand Directed By Engg-In-Charge 123 Boringfor Road Crossingin Any Kind Ofsoil / Rock Strata Complete All As Specifiedand Directed By Engg-In-Charge 124 Supply & Laying Gi Pipe Light Graded Of Size 50Mm Diain Trenches And Fixing On Wall / Poleswith Help Of Suitable Size Ms Clamp For Cable Protectioncomplete All As Specifiedand Directed By Engg-In-Charge 125 Supply & Laying Gi Pipe Light Graded Of Size 80Mm Diain Trenches And Fixing On Wall / Poleswith Help Of Suitable Size Ms Clamp For Cable Protection Complete All As Specifiedand Directed By Engg-In-Charge 126 Supply, Fixing & Stretcing Aluminium Conductor Steel Reinforced ( Acsr ) Of Any Type And Size Fixedon Existing Steel Tubular / Pcc Ht / Lt Pole Fixed On Insulators And Binding With & Including 2 Mm Binding Wire Complete All As Specified And Directed By Engineer-In-Charge. Notes :- I ) The Acsr Conductors Shall Be Conforming To Is- 398 ( Part-Ii ) And As Specified In Ssrpart-I .Ii ) The Unit Rate Quoted Shall Alsobe Deemed To Include For Supply And Fixing Of Binding Wire, Aluminium Tapes Etc Which Shall Not Be Included In The Weight Of Conductors For Payment.Iii ) Weight Of Conductors Shall Be Determined By Measuring The Horizontal Distance Between Centres Of Two Adjacent Poles And Compounding The Weight Of Conductors Of That Size Multiplied By Lenght Of Span And 3 % Extra Shall Be Added For Sag, Jointing, Jumpers Etc.Iv ) Weight Of The Conductors Shall Be Calculated From The Nominal Weights Given In Tables In The Relevant Is. 127 M&L For Painting Of Transformer Foundation With Two Coats Of Obd After Complete Scrapping Of Old Paint / Whitewash And Making Good Surface Complete All As Specifiedand Directed By Engg-In-Charge 128 M&L Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Complete All As Spd And Directed By Engg.In.Charge. 129 M&L For Providing Earthing Complete With Galvanised Iron Earth Plate Electrode 600 Mm X 600 Mm X 6Mm As Earthing Lead Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Mtr Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To And Including Galvanised Iron Strip 25X4 Mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts & Washers Etc Made Of Gi And Connected To Earthing Test Point, Providing Charcoal And Common Salt All As Shown In Electrical Plateno. 5 Of Ssr Part I Of 2009 & As Specified Or Indicated And Testing On Completion Including Exaction / Earth Work In Any Type Of Strata Pcc ( 1:3:6 ) Type C1 Earthing Chamber, Pre Cast Slab 50 Mm Thick In Cement Concrete ( 1:2:4 ) Type B1 ( Reinforced With Welded Steel Wire Fabric ( Xpm ) Weight Not Less Than 4 Kg / Sqm ) , Funnel With Wire Mesh, Watering Pipe Of 20 Mm Bore Medium Grade And Lugs, Including Galvanised Iron Strip 25X4 Mm With Gi Protection Pipe Of 20 Mm Medium Grade 7.5 Meter Long, Etccomplete All As Specified And As Directed By Engr-In- Charge.Note:- ( I ) Venders Are Bound To Get Earthing Result Upto 5 Ohm For Single Earthings And 3 Ohm With The Grid Of Two Earthing.Any Additional Work And Material Required To Achive The Required Result Is Included In The Cost Deemed To Be Quoted Rate By Contractor. ( Ii ) Excavated Material To Be Removed From The Site And Deposit At The Distance Not Exceeding 50M Distance And Levelled. ( Iii ) Refill The Pit With M&L For Black Cotton Soil 1 Cum. ( Iv ) On Testing After Completion If The Desired Earth Resistance Is Not Obtained The Earthing Will Be Redone At No Extra Cost. ( V ) Taking Down All Items In Respect Of Existing Earthing Is Included In The Cost Deemed To Be Quoted By Contractor.

Key Dates

Contract Date 07 Nov 2022

Contact Information

Company Name
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 2490445 sapana enterprises INR 3222051.50
Contract Value 3 Million
Contract Date 07 Nov 2022

View Notice Now...

Login with your Social Account for Instant Access to this notice


Tell us about your Product / Services,
We will Find Tenders for you