Supply, Delivery, Installation, Commissioning & Trial Run Of Submersible Pumping Machinery And Other Electro Mechanical Accessories For Bhaluk Chua T / W No. I Stand Alone Piped Water Supply Scheme Of Jhargram District Under Jhargram Mechanical Division, P.H.E Dte.- 1 Supply And Delivery Of Following Materials At Site:- Submersible Pumping Machinery Directly Coupled With Submersible Motor Suitable For Above Pump Having Power Supply At 230V ( ±10% ) , 50 Hz ( ±3% ) Material Of Construction :Pump Bowl.Housing : C.I. Pump / Motor Shaft : Ss-410. Impeller : Bronze / Cs / Ss Nrv Size: 50 Mm Starting Method : Dol Speed : 2900 Rpm Max. I ) Q = 5.0 M3 / Hr Ii ) H = 62 Mtr ( Test Certificate, H&Q Characteristic Curve Shall Be Submitted At The Time Of Delivery ) Make:- As Per Approved Vendor List Of Phed Vide No.Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 2 50 Mm Dia Upvc ( Standard Type ) Column Pipe With Both Side Threaded And One Side Socketed.A ) 3 Mtr. Long 3 B ) 1.5 Mtr Long 4 C ) 50 Mm Dia Top & Bottom Adoptor ( Ci ) 5 102 Mm. Dia 0-7 Kg / Cm² Range Wall Mounted Bourdon Type Glycerine Filled Pressure Gauge Complete With Brass Cock & Other Fittings As Per Direction Of E.I.C. ( For Tubewell Outside The Pump House. ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 6 102 Mm. Dia. Wall Mountedbourdon Type Glycerine Filled Depth Gauge Capable To Measure Direct Reading In Feet With 6 Mm Pvc Air Pipe With Socket ( Assembly Should Be 50Mtr. Long ) Including Supply Of One Good Quality Hand Pump For Tubewell Outside The Pump House. ( This Cost Includes 15 Mm. Dia. G.I. Pipe Approx. 40 Ft. Length And Specials ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 7 M.S Fabricated Split Type Suitable Tube Well Cover As Per Tube Well Housingwith Necessery Clamping Arrangementincluding Provision Of Holes For Column Pipe , Air Pipe And Cable Entry Etc. All Complete As Per Direction Of E.I.C 8 Anti-Snapping Safety Device For Above Pump By Supplying Suitable Size Nylone Rope Of Required Length ( Double ) Including Supply Of All Necessary Materials As Required. 9 M.S Suspention Clamp With Necessery Nuts, Bolts & Washersetc.Suitablefor 50 Mm Dia Pipe ( Size 300 Mm X 50 Mm X 8 Mm Each ) 10 1.1 Kv Grade 415 V, 2 Core 10 Sq.Mm. Pvc Sheathed Xlpe Insulated Al. Armoured Cable Conforming To Is:7098 ( Part-1 ) 2011 With Latest Amendmends As Applicable. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 11 1.1 Kv Grade, 2.5 Sq.Mm. 3 Core Pvc Insulated & Sheathed Copper Flat Submersible Cable Conforming To Is:694 ( Part-1 ) With Latest Amendmends As Applicable.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 12 50 Mm Dia, P.N. 1.0, Cidf Non Return Valve Conforming To Is: 5312, Part-I. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 13 50 Mm Dia, P.N. 1.0, Cidf Sluice Valve Conforming To Is: 13095. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 14 50 Mm Dia , Pn-1.0 Cidf Wafer Typebutterfly Valve Conforming To Bs: 5155.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 15 50 Mm Dia Heavy Type Suitable Length Ci / Ms Black Pipes ( For Common Delivery Header, Backwash Line For Pump Under Sl No-1, Along With Necessary Bends, Short Piece, Specials, Fittings , Viz Flanges, Bolts, Nuts, Gaskets, Concentric Enlarger , Ms Dismenteling Joint, For Connecting Main Pipe Line Etc. Including Providing Ms / Bricks / Pcc Support For Laying Of Pipes, Valves As Required To Make The Installation Complete. 16 230 V Pdb Cum Mcc Panel ( 1-3 Hp With Dol, Direct Online Starter ) With Minimum 2 Mm Thick Crca Sheet Enclosed And Degree Of Protection Ip-54, Conforming Tois-8623 With Suitable Bus Bar, Digital Voltmeter, Ammeter, Contactor, Delay Timer, Mcb, Valve Actuator, Starter Etc. With Plc Logic As Detailed In Attached Technical Specification. ( Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 17 6 Kva, Single Phase, Oil Cooled Type Auto / Manual Servo Voltage Stabilizer Having Unbalance 115-289V Input Voltage And 230 V ( ± 1% ) Output Voltage, With U / V, O / V, O / L Protection With Mccb At Input &Mcbat Output Side, Ammeter, Bell Etc. As Per Ie Rules And As Per Technical Specification. Make:-As Per Approved Vendor List Of Phed Vide No Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 18 Chlorination System With All Equipment And Accessories As Per Following Specification:- 1 No. Dosing Pump Of Capacity 0-100 Lit / Hr. Max. Discharge And 10 Kg / Cm². Pressure Maxwith Motor 0.5 Hp, 1 Ph, 50Hz 220 Volt, 1440 Rpm Tefc Cooling Motor, Base Plate Rate Adjustment Device Etc. Ii. 100 Lit Hdpe Dosing Tank For Storing Of Chlorine Solution. Iii. Necessary Gi Pipe Fittings And Hdpe / Pvcpipe Line For Dosing The Solution With All Accessories As Per Requirment. Pump Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. ( Motor Make- Cgl / Kec / Abb / Any Approved Make ) 19 Led Street Light Luminarie Having Ip 66 Lm6-Hpdc Housing , Aerodynamically Designed With Better Thermal Management / Potted Driver Is To Be Provided.The Luminaire And Housing Should Be From The Same Manufacturer ( Cat No- Brp052 Led 045 Cw Slmr Fg S1 Psu Gr , System Efficacy Greaterthan 100 Lumen / Watt ) Make- Philips. The Manufacturer Has To Provide Lm79 / Lm80 Reports Corresponding To The Luminaire / Led Chip Along With Type Test Certificate.Respectively The Luminaire Manufacturer Should Have An In House Nabl Accredited Testing Facility. 20 63 Amp, 10 Ka, 240 / 415V, 50 Hz Double Pole Mcb Isolator Conforming To Is / Iec: 60947-3, C Characteristics With Enclosure. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 21 6-32 Amp Amp, 10 Ka, 240 / 415V, 50 Hz Sp Mcb Conforming To Is / Iec: 60898-1, C Characteristics. ( 6 Amp- 2 Nos., 10 Amp-1 No., 16 Amp-1 No. ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 22 10 Amp, 10 Ka, 240 / 415V, 50 Hz Spn Mcb Conforming To Is / Iec: 60898-1, C Characteristics.Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 23 6 Way Sp&N Double Door Horizontal Distribution Board ( I / C 2 + O / C 4 ) Conforming To Is 13032 & Is 8623 And Ip42 / 43. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 24 Pvc Mouldedchair Without Arm. ( Make:- Nilkamal / Supreme / Cello ) 25 Pvc Moulded Table Of 850 X 850X 725 Mm Size. ( Make:- Nilkamal / Supreme / Cello ) 26 63 Amp, 240 / 415 V Porcelain Fuse Unit ( Base & Bridge ) Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 27 Hard Wooden Board ( 450Mm X 304.8 Mmx 2 Mm Thick ) 28 Installation Of Itemlaying Of Cable ( As In Item No. 10 ) On Wall / Surface Incl. S & F Of Ms Saddles With Earthing Attachment In 10 Swg Gi ( Hot Dip ) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting All Complete As Per Direction Of E.I.C. 29 Supplying And Fixing Of Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Ofcable ( As In Item No. 10 ) All Complete As Per Direction Of E.I.C. 30 Finishing The End Of Cable ( As In Item No. 10 ) By Crimping Method Incl. Supplying And Fixing Solderless Socket ( Dowels Make ) , Tapes, Anticorrosive Paste & Jointing Materialsall Complete As Per Direction Of E.I.C. 31 Making Internal Wiring / Electrification Of The Pump House By ( 2X 22 / 0.3 ( 1.5 Sqmm ) + 1X 22 / 0.3 ( 1.5 Sqmm ) Single Core Pvc Insulated Multistrand Frlsh Grade Flexible Copper Wire Through 20 Mm Pvc Conduit Pipe / Casing By Supplying One No. 40 Amp, 10Ka, 240 / 415V, 50 Hzspn / Dp Mcb Isolator Conforming To Is / Iec: 60947-3, C Characteristics. ( As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments ) With Required Module Pvc Board & Piano Key Type Switch. ( Ave. Run 6 Mtr ) . I ) Led Tube Set Point-2 Nos., Bulk Head Light Point- 1 No., 5 Pin 6 Amps. Plug Point- 1 No., 16 Amp Socket & Switch- 1 No, Indicator- 1 No. Each, With Necy. Earthing Arrangement & One Fan Point ( Total Point 6 Nos. Points ) Including Drawing Power By Suitable Gauge ( 2.5 Mm2 ) Of Copper Wire From Installed Cut-Out To Spn / Dp Mcb Within Db Through 20 Mm Pvc Casing Capping ( Precision Make ) As Per Direction Of Eic ( Fittings Should Be Of Philips Make & Wiring Should Be With Continuous Earthing Arrangement And 20 W Two Nos. 4 Ft Long Led Tube Light Setsphilips Astra Line, One No. Bulk Head ( Endura Wt202w Led6s Nw Psu S2 Pc ) , One No. 0-4 Step Fan Regulator ( Humfree ) , Fittings Etc To Be Supplied By Agency ) . 32 Installation, Testing & Commisioning Of Above Supplied Pumping Machinery Mcc Panel, Valves Etc. ( Item No 1 To 9, 12 To 16, 17, 20 To 23, 26, 27 ) By Jointing Submersible Cable Within The Tubewell Situated Outside The Pump House By Making Derrick Arrangement By Assembling The Column Pipes Properly And Fitting, Fixing The Pressure Gauge, Depth Gauge, Air Pipe Etc. In Position And Erection Of Delivery Line & Wash Out Line With The C.I Specials And Tee Including Mending Damages Goods Etc.All Complete As Per Direction. This Also Includes The Charges For Laying Submersible Cable From Tubewell To Control Panel By Underground And Saddle On Wall And Connection With Required Feeder Of Panel All Complete. 33 Making Suitable Size Pump Foundation Base ( Size: 1.00 Mtr. X 1.00 Mtr. X 1.5 Mtr. ) With Supplying Cement, Sand, Stone Chips Etc. In The Portion Of ( 4:2:1 ) Including Plastering, Neat Cement Finishing Etc. All Complete As Per Direction Of Eic. ( I ) Tubewell Outside Pump House. 34 Making Required Nos. Of Brick Pillar 0.25 Mtr. X 0.25 Mtr. For Supporting Of Valves And Pipes With 12 Mm Thick Plaster And Net Cement Finish All Complete. 35 S&F Of 3 Dia 1.5 Mt Minipole With Baseplate To Be Fixed On Rooftop Incl. S&F Of 1.5 Mtr Long Arm Bracket ( Removable Type ) Incl. Cc ( 6:3:1 ) Muffing ( 450X450x600 ) With 3 Mm Thick Neat Cement Finish & Painting Incl. S&F Of 200X150x100 Mm 16 Swg Gi Loop Box With Necessary Power Connection By3x 22 / 0.3 ( 1.5 Sq.Mm ) ( 2 Nos. P&N And 1 No. Ecc ) ''''Frlsh'''' Pvc Insulated & Unsheathed Copper Wire ( Approved Make ) In 20 Mm Size Pvc Rigid Conduit ''''Frlsh'''' ( Precision Make ) Incl. Necy. Fittings As Required As Per Direction Of Eic. ( For 12M Length ) 36 ( A ) Earthing With 50 Mm Isi Mark Medium Diameter G.I. Pipe 3.64 Mm Thick X 3Mtr. ( 10Ft. ) Long And 1 X 4 Swg G.I. Wire ( 4Mtr.Long ) 13 Mm Diameter X 80Mm ( 3Inch ) Long G.I. Bolts, Double Nuts, Washer Including S & F Of 15Mm Diameter G.I. Pipe Protection ( 1 Mtr. Long ) To Be Filled With Bitumen Partly Below Ground Level To An Average Depth Of 3.65Mtr. ( 12Ft. ) Below The Ground Level And Restoring The Surface Duly Rammed.I ) For Soft Soil By Isi Medium Gi Pipe. 37 ( B ) Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36 Cm X 86.36 Cm X 46 Cm Deep ( Below Ground Level ) Complete With Cemented Brick Work ( 1:6 ) Of 25 Cm Width Duly Plastered With Cement Morter ( Inside ) Ci Hinged Inspection Cover Of Size 36.56 Cm X 35.56 Cm With Locking Arrangement, Gi Reducer Including Drilling Of 46 Nos. 12 Mm Diaholes On The Gi Pipe. 38 ( C ) Extra For Treatment Of Soil By Salt And Charcoal Coke For Pipe Electrode. 39 ( D ) Supplying & Fixing Earth Busbar Of Galvanized ( Hot Dip ) Ms Flat 25 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required.Length Of Busbar Is 0.5 Mtr. 40 Installation & Commissioning Of Above Chlorinator With Supplying & Drawing Of Suitable Length 1.1 Kv Grade 2 X 36 / 0.3 ( 2.5 Sqmm ) Single Core Stranded ''''Frlsh''''pvc Insulated & Unsheathed Copper Wire ( Approved Make ) From Installed Panel Board Through 20 Mm Size Pvc Rigid Conduit ''''Fr'''' ( Precision Make ) Incl. Necy. Fittings As Required And Continuous Earthingfrom Nearest Earth Grid. Thisincludes The Cost Of Making Required Height Brick Foundation Base With Neat Cement Finishing By Supplying All Required Materials And Testing The Entire Set Asper Direction Of Eic. ( Height Of Tank Foundation Shall Be Higher Than That Of Chlorine Machine ) 41 Supply, Delivery And Fitting-Fixing Of 230 Volt , 1200 Mm Sweep Ac Ceiling Fan With Ball Bearing Complete With All Accessories Such As Blade, Canopy, Fork, Down Rod Etc. Make :- As Per Approved Vendor List Of Phed Vide No. Phe / Iv / 2277 / W-181 / 19 Dated 25.09.2019 With Latest Amendments. 42 Trial Operation And Guarding Of The Installed Pumping Machinary After Receiving Power And Commisioning The Pumping Machinary As Per Direction Of E.I.C 43 Add: 18% Gst 44 Add: 1% Cess
|