Contract Award Notice |
|
TRR | 9064449 |
Organization | Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited |
Tender No | DGM/STC/GNA/ PUR/2022-23/12/1021 dt 26.07.2022 |
Funded By | Self-Funded |
Country | India , Southern Asia |
Contract Value | 79,602 |
Work Detail |
Revised Estimate For Electrification Of Goshala At Village Kamkhedi Under Eshagarh Dc- 1 Schedule A :- 25 Kva X-Mer On Pcc Pole - 01 No., Schedule B :- 11 Kv Line Of Pcc Pole - 0.2 Km, Schedule C :- 11Kv Dp Structure - 01 No. 2 Dtr 25 Kva 11 / 0.4 Kv Bis Certified Level-Ii 3 Dtr 25 Kva 11 / 0.4 Kv Bis Certified Level-Ii ( Labour Charges For Handling & Installation Of Distribution Transformer ( Dtr ) On Dp, Tightening With Turn Buckles On Both Sides, Poles Clamping And Boting Of Base Jumpering On Ht Side ] 4 P.C.C. Pole 140 Kg. 8 Mtr. Long 5 P.C.C. Pole 140 Kg. 8 Mtr. Long ( A ) . Pole Pit Digging In Soft Rock For 140 Kg Pcc Pole [ Size ( 2X4X4.5 ) = 36 Sq. Feet ] ( B ) . Pole Transportation 00Km Upto 01Km ( C ) . Pcc Pole 8 Mtr Long 140 Kg Erection With Earthing 6 11Kv Gapless Type Polymer Lightening Arrestor ( 1Set=3No. ) 7 Labour Charges For Fixing Of 11Kv Gapless Type Polymer Lightening Arrestor ( 1Set=3No. ) 8 Stay Set 16Mm Complete Without Stay Wire ( Painted ) 9 Stay Set 16Mm Complete Without Stay Wire ( Painted ) A ) . Stay Pit Digging ( 16 Mm ) Size ( 5X2.5X5 ) = 62.50 Cu. Feetb ) . Stay Set Erection ( Complete With Binding Of Stay Wire At Eye Bolt, Stay Insulator And Anchor Rod ) 10 Stay Wire 7 / 3.15 Mm ( 7 / 10 Swg ) 11 Stay Insulators 90X65mm 12 Clamp For 140Kg Pcc Pole Ms Flat 50X6mm 13 Stone Block / Pre Cast Block For Base Pedding ( 450X450x75mm ) 14 Concreting Of Pcc Pole @0.45Cmt. / Pole 15 Labour Charges For Concreting Of Pcc Pole @0.45Cmt. / Pole 16 Concreting Of Stay @ 0.2 Cmt. Per Stay 17 Labour Charges For Concreting Of Stay @ 0.2 Cmt. Per Stay 18 Aaac Rabbit Condt.. 0.05Sq. Inch 19 Danger Boards Enamalled Type 11Kv. 20 Labour Charges For Fixing Of Danger Boards Enamalled Type 11Kv. 21 Bimetalic Clamp Distribution Transformers Bushing 22 Bi-Metallic Clamps Suitable For 12Mm Dia Stud And 80Sqmm Aaac 23 Anti Climbing Device ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 24 Labour Charge For Fixing Of Anti Climbing Device ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 25 Red Oxide Paint 26 Aluminium Paint 27 M.S. Nut And Bolts 28 Meter Cum Protection Box For 25 Kva Dtr 29 Xlpe 1Core Unarmoured 35Sqmm Alu. Condt.1100 Volts 30 Three Phase Static Energy Meters 20-80 Amps With L.S. & Tod Facility With Box 31 Three Phase Static Energy Meters 20-80 Amps With L.S. & Tod Facility With Box [ Labour Only For Installation Of Three Phase Meter On 12 X16 Poly Carbonate / Wooden Board ( Excluding The Cost Of Board ) , But Including Making Holes In The Board, Fixing The Board On The Wall, Screing The Meter On The Board, Screwing Incoming & Outgoing Terminals Including Earth Terminals ] 32 11Kv Composite Polymer Disc Insulator 33 11Kv Strain Hardware Fitting 34 Back Clamp For 140Kg Pcc Pole Ms Flat 50X6mm 35 11 Kv. D.O. Fuse Unit ( 1Set=3No. ) 36 Labour Charges For Fixing Of 11 Kv. D.O. Fuse Unit ( 1Set=3No. ) 37 Transformer Mounting Channel ( 100X50x6mm ) 38 Trans.Mounting With Belting With 50X50x6mm Angle With Two Cross Fixing Channel 39 Dc Cross-Arms 8 Channel ( 100X50x6mm ) 40 Fixing Of Dc Cross-Arms 8 Channel ( 100X50x6mm ) Along With Plates, 6 Nos, H / Ws, 6 Nos. Disc Insulators And Fixing Of Supporting Clamps On Both The Poles 41 D.O.Mounting Channel 75X40x6mm 42 Labour Charges For Fixing Of D.O.Mounting Channel 75X40x6mm 43 Fixing Of Transformer Mounting Structure Complete With Base Channel, Supporting Clamps And Belting Of Fixing By Turn Buckles 44 Stay Insulator 90X65mm 45 Back Filling Of Poles With Boulders.1 46 G.I. Wires 4.0 Mm ( 8 Swg ) 1 47 11 Kv V Cross Arms 65X65x6mm 48 Fixing Of 11 Kv V Cross Arms 65X65x6mm With 11 Kv Top Clamps 49 Aluminium Binding Wire And Tape 50 11 Kv Top Clamp 65X65x6 Mm Angle Type 51 Earthing Coil Of 115 Turns Of 50Mm Dia And 2.5Mtr. Lead Of 4.0Mm G.I. Wire 52 11Kv Polymer Pin Insulator 53 Labour Charges For Fixing Of 11Kv Polymer Pin Insulator 54 Jointing Sleeves Suitable For Rabbit ( 55 Sq.Mm Al. Eq. ) Aaac Conductor 55 Aaac Raccoon Conductor 0.075Sq. Inch ( 03No. Condt. ) 56 Stringing Of Aaac Raccoon Conductor 0.075Sq. Inch ( 03No. Condt. ) 57 Survey Of 11Kv Line During Execution Of Work 58 Bracing / Support Angle Of 65X65x6 Mm Angle For 8 ( 2.4 Mtr. ) Centre Dp With Supporting Clamps On Both The Poles 59 Fixing Of Bracing / Support Angle Of 65X65x6 Mm Angle For 8 ( 2.4 Mtr. ) Centre Dp With Supporting Clamps On Both The Poles 60 Concreting Of Stay @ 0.3 Cmt. Per Stay 61 Labour Charges For Concreting Of Stay @ 0.3 Cmt. Per Stay 62 Earthing For Pcc Pole 4.00 Mm - 8 Swg G.I. Wire - 0.8 Kg / Pole 63 Ms Strain Plate 65X8 Mm 250 Mm Long 64 Gst @ 18% |
Key Dates |
|
Contract Date | 28 Oct 2022 |
Contact Information |
||||||||||||||||||||||||
View Notice Now...Login with your Social Account for Instant Access to this notice
|