Providing And Fixing ( Electrical Items ) In Officers Training Institute In Police Lines, Sector 30, Faridabad - Hsr Items 2 ( Hsr 24.1 ) Earthing And Lightening Arrestor 3 24.1.3 ) Earthing With G.I. Earth Plate 600 Mmx 600 Mm X 6 Mm Thick Includingaccessories And Providing Masonry Enclosures With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal Or Coke And Salt ) Complete As Required. 4 24.1.4 ) Earthing With Tinned Copper Earth Plate 600Mmx600mmx3mm Thickincluding Accessories And Providing Masonry Enclosures With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal Or Coke And Salt ) Etc. Complete As Required. 5 24.1.5 ) Extra For Charcoal Or Coke And Salt For G. I. Plate Or Copper Plate Earthelectrode. 6 24.1.8 ) Providing And Fixing 25 Mm X 3Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required With All Labour And Material. 7 24.1.10 ) Providing And Fixing 25 Mm X 5Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required With All Labour And Material. 8 ( Hsr-24.2.4 ) Laying Of Underground Cable In Pipe / Existing Open / Closed Trench Etc As 9 24.2.4.3 ) 50 Sq Mm To 150 Sqmm 2 To 4 Core 10 ( Hsr 24.2.7 ) Supply And Erection Of Suitable Compression Type Brass Cable Glands For Underground Cable :- 11 24.2.7.4 ) 70 Sqmm To 95 Sqmm Cable 2 To 4 Core 12 ( Hsr 24.2.8 ) Supply And Erection Of Aluminium Lugs Heavy Duty Including Crimping Etc. Up To The Entire Satisfaction Of The Engineer-In-Charge Of The Work . 13 24.2.8.6 ) 35Sqmm 14 24.2.8.8 ) 70 Sqmm 15 Providing Rcc Foundation Of M20 Grade ( 1 Cement:1.5 Stone Aggregate: 3 Coarsesand ) I / C Excavation, Steel Reinforcement ( Fe 500 ) @ 50 Kg / Cum Of Concrete Contents, Concrete Cover 50Mm, Over A Bed Of 75Mm Thick Pcc 1:5:10, Of Required Dimensionsas Per Oem Recommendations To Provide Levelled Surface For Placement Of The Dg Set Complete In All Respects And As Per Directions Of Engineer-In-Charge ( Size Of Foundation Assumed = 5.0X1 .Bx1 .Om ) Note: As Size And Dynamic Load Of Dg Sets Vary From Manufacturer Tomanufacturer, Item Of Dg Set Foundation Have Been Included On The Basis Ofcubic Contents Of Rcc. 16 24.7.2 60 To 90 Kva Dg Set 17 Hsr Estate Electrical Total 18 Ns Item 19 Supply Of Ltcable Of Following 1100 Volt And Complete With Making Necessary Connection Of Cable On Both Ends Including Loading Unloading & Carriage With All Labour And Petty Material Required To Complete The Job Upto The Entire Staisfaction Of Engineer - In - Charge Of The Work. 20 4 ) Cable Of Size 70 Sqmm 3.5 Core ( Armoured ) 21 S / I / T / C Of High Wall2.0 Tr Capacity Ofinverter 5- Star Rating Air- Conditioning Unit ( Make-Hitachi Model Kiyora 5100X- Invtr -Rmr G 524Heea-Sac Or Equivalent Model Of Make As Per Approved Make List ) Rated At 220 Volts ( + ) ( - ) 10%, Single Phase, 50 Cycle Per Second Electric Supply And Consisting Of Condensing And Indoor Unit, Control Panel Of The Unit, Lcd Cordless Remote, Internal Control Wiring, Thermostats, All Accessories And First Charge Ofgas & Oil But With 3.0 Mtr Copper Refrigerant & Drain Pipe. The Work Shouldbe Completed In All Respect Including Making Repair Of Wall, Floor And Roof In Original Shape Caused By Making Holesand Chases Etc. 22 Supply And Erection Of 55” Ledsmart 4K Tv, ( Samsung / Sony / Pansonic - Make ) Complete In All Respect Including Installation Making Necessary Connections Etc Complete In All Respect Upto Entire Satisfaction Of Engineer-In-Charge. 23 A. Supply , Installation, Testing And Commissioning Of 62.5 Kva Water Cooled , Silent Diesel Generating Set Complete With Alternator Rated At Three Phase 415 Volts, 0.8 Power Factor, 50 Cycle Per Second , 1500 Rpmwith Amf Panel ( Outside / Inside The Canopy ) , Acoustic Enclosure And Battery Charger Etc. ( To Be Installed Out Door On Existing Platform Excluding Cost Of Platform ) : - ( A ) Diesel Engine : Engine Multi Cylinder, Developing Output As Per 62.5 Kva Dg Set At 1500 Rpm, Vertical, Totally Enclosed, Water Cooled, Comprising Compression Ignition, Electric Start, 4 Stroke High Speed Diesel Engine Conforming To Is - 4722 , Iso - 3046, Bs - 5514. The Engine Shall Be Complete With All Standard And Electrical Accessories As Per Standard Supply Of Manufactures. The Engine Shall Be Coupled With 3 Phase 415 Volts, 50 Cycle, 0.8 Pf & 1500 Rpm, Alternator As Per Is - 4722 / Bis - 2613, Rated For 24 Hours Of Continuous Operation With 10 % Over Load Capacity For One Hour In Every 12 Hours And Comprising With :-A ) Amf Panel Of Required Size Complete With All Accessories As Required , Ip-53 Protection As Per Is / Iec :60947 ( Part-I ) / 2007B ) On / Off Start Keysc ) Lube Oil Pressure Gauged ) Fuel Tank With Capacityfor 8 Hours Continuous Running At Full Load 24 B. Residential Silencer Of Required Size And Length I / C All Necessary Material As Required.F ) 1 No, 12 Volts, 150 Ah, Dc Mtr. Free Batteries With Leads & Container.G ) Avm Pads Fitted On Base Frameh ) The Base Frame Would Be Fabricated From Suitable M.S. Channels Suitable Machined To Perfect Alignment Of The Engine And Alternator With Rigid Construction And Necessary Reinforcement To Ensure Minimum Vibration. ( I ) Ac Digitalvolts And Amperes Metres With Selector Switch Of Class 1.5 Accuracy ( J ) Mccb Of Suitable Capacity On Output Of Dg Set ( K ) 4 Pole Mccb Of 63 Ampcapacity On Output And Input Side Of Amf Panel ( L ) 4 Pole Contractors Of 80 Amp Capacity In Amf Panel ( M ) Pilot Lamps 3 Nos. ( N ) 5 Nos. Indicating Lamps To Indicate Main Low Voltage , Load On Mains , Dg Set Running , Load On Set And Battery Charger On ( O ) Under Voltage Relay For Mains ( P ) Over Voltage Protection ( Q ) Any Other Accessories To Make The Generating Set Functional Shall Be Installed As Per ManufacturerS Specification. 25 C. ( B ) Battery Charger: The Battery Charger With Volt Metre And Ammeter Shall Be Installed Of Required Size And Rating For Charging Of Battery From Mains. This Will Be In Addition To The Battery Charging Alternator Fitted On The Engine. ( C ) Accoustic Enclosure : Acoustic Enclosure Shall Be Provided As Per Technical Specification As Follows :-1 ) Construction & Painting : I ) The Enclosure Shall Be Fabricated Out Of 1.6 Mm Thick ( 16 Swg ) Crca Sheet Silent D.G. Set Container Shall Be Of Modular Construction With The Provision To Assemble And Dismantle Easily At Site Of Work.Ii ) The Base Fame Shall Be Made Of Ismc Of Suitable Section.Iii ) Durable Industrial System Is To Be Provided On The Doors And Doors Are Fitted With High Quality Epdm Gasket To Avoid Leakage Of Sound. Iv ) Weather Proof Anti Corrosion Treatment To Be Provided To The Entire Structure With Powder Coating.V ) Neutral / Body Earthing Points At The Side Of Enclosure Are To Be Providedvi ) Emergency Stop Push Button Shall Be Provided Outside The Container.Vii ) A Tube Fitting With Tube Rod For Proper Light Inside The Canopy Shall Be Provided. 26 D. ) Accoustic Insulation :I ) Sound Proofing Of The Enclosure Shall Be Done With Quality Rock Wood / Mineral Wood Conforming To Is-8183-1993 Of 25Mm Thickness And Density At 30 Kg. / M Compressed Along With 3Mm Thick Vinyl Sheet And Non Ferrous Sheet. Ii ) Exhaust Pipe Is To Be Thoroughly Insulated By Covering It With Glass Wool And Further Claded With Aluminium Sheet.Iii ) 75 Db A Noise Level As Per Central Pollution Control Board ( Cpcb ) -Ii With Latest Amanedmentsnote Any Other Material Required To Complete The Acoustic Enclosure Shall Be Installed As Per ManufacturerS Specifications. 27 Total N.S
|