Provn Of Clothing And Medical Store At Army Area Under Ge Shikargarh Jodhpur- Excavation In Trenches N.Exc 1.5 M Wide & N.Exc 1.5 M In Depth For Foundation Etc Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc N.Exc 10 Sqm On Plan And N.Exc 1.5 M In Depth And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed. 2 M&L Pcc 1:4:8 Type D2 ( 40 Mm Graded Aggregate ) In Foundation Filling And Mass Concreteetc Complete Etc.All As Specified And As Directed. 3 M&L For Brick Work With Fly Ash Bricks ( Old Size Bricks ) , Straight Or Curved On Plan Exc 6Mtr Mean Radius, Built In Cement Mortar ( 1:6 ) Complete All As Specified And As Directed. 4 M&L For Form Work To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides Of Soffits ( If Any ) Of Foundations And Plinth Beams And Similar Work Etc; Rough Finish Surfaces Complete All As Specified And As Directed. 5 M&L For Form Work To Sides Of Concrete Pillars, Posts, Struts, Piers, Columns And Stanchion Etc; Rough Finish Surfaces Complete All As Specified And As Directed. 6 M&L For Form Work To Sides And Soffits Of Floor Or Roofrcc Beam Sides Of Lintel Beam Flat Rough Finish Surfaces To Receive The Plaster, Complete All As Specified And As Directed. 7 M&L For Formwork For Chullah Hoods, Chajjas Through And Similar Items Including Edges, Surface Rough Finish Surfaces To Receive The Plaster, Complete All As Specified And As Directed. 8 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) , Rough Finish Surfaces Complete All As Specified And As Directed. 9 M&L For Form Work To Edges Of Concrete Flats, Floor And Roofs Not Exceeding 20Cm Wide ( Horizontal Or Sloping ) , Rough Finish Surfaces Complete All As Specified And As Directed. 10 M&L For Providing Rcc 1:1-1 / 2:3 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Foundations, Including Raft Footings, Foundations Beams, Plinth Beams, Bases Of Columns Etc; Complete All As Specified And As Directed. 11 M&L For Providing Rcc 1:1-1 / 2:3 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Columns, Pillars, Piers, Posts And Struts Etc; Complete All As Specified And As Directed. 12 M&L For Providing Rcc 1:1-1 / 2:3 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Beams, Lintel Up To 1.5M Clear Span, Lintel Bands Etc; Complete All As Specified And As Directed. 13 M&L For Providing Rcc 1:1-1 / 2:3 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Slabs Supported On Walls, Beams And Columns In Roof, Landings, Balconies, Canopies And In Shelves Etc; Complete All As Specified And As Directed. 14 M&L For Providing Rcc 1:1-1 / 2:3 Type B1 ( Using 20Mm Graded Stone Aggregate ) As In Chajjas Etc; Complete All As Specified And As Directed. 15 M&L For Reinforcement 10Mm Dia And Over Tmt Bars Cut To Length, Bent To Shape Required And Binding With Ms Wire Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And As Directed. 16 M&L For Reinforcement 8 To 10Mm Dia Tmt Bars Cut To Length, Bent To Shape Required And Binding With Ms Wire Not Less Than 0.9Mm Dia In Stirrupscomplete All As Specified And As Directed. 17 M&L For Carrying Out Water Proofing Treatment Forroofs In The Following Stages - ( I ) Rendering 10Mm Thick In 1:4 Mixed With Integral Water Proofing Liquid All As Per ManufacturerS Instructions Over Concrete Surfaces Finished Even And Smooth With Out Using Extra Cement. ( Ii ) First Coat Of Bitumen Primer Confirming To Is 3384 @0.300 Kg / Sqm Over Plastered Surafces ( Iii ) Secondlayer Of 3.0 Mm Thick App Modified Polymeric Membrane With Centre Core Of Single Non Woven Polyster Reinforcementandhaving Weight 3 Kg / Sqm With Mineral Gravel Finish On Top Complete Laid With Blown Type Bitumen Grade 85 / 25 @ 1.20 Kg / Sqm Complete All As Specified And As Directed. ( Iv ) Finally Applying Two Protective Coats Of Bituminous Aluminium Based Reflective Paint To Safeguard Against Uv, Including Preparing Of Old Surfaces Of Roof Remove All Corrosion Products Brooming Down Or Steel Wire Brushing; Scrapping Down Smoke Soot, Moulds, Moss And Efflorescent Salts And Trading Oil And Greasy Spots Incl Washing , Rubbing Down And Stopping Of Painted Surfaces ( Second Coat Apply After 24 Hrs Or As Per Manufacturing Instructions ) . 18 Supply Only Integral Water Proofing Liquid Isi Marked Make: Pidiproof Lw 19 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Each Layer In Hard / Dense Soil All As Specified And Directed. 20 Removing Excavated Soil N Exc 50 M And Depositing Where Directed At A Level N Exc 1.5 M Above The Starting Point All As Specified And Directed. 21 M&L For 15 Mm Thick Rendering On Stone / Brick Masonary Wall Surfaces In Cm 1:4Finished Fair And Even All As Specified And As Directed. 22 M&L For Rendering 15 Mm Thick In Cm 1:6 Finished Even Without Using Extra Cement Over Stone Wall Surfaces All As Specified And As Directed. 23 M&L For 10Mm Thick Rendering In Cm 1:3 On Ceiling Surfaces Finished Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 24 M&L For 75Mm Thick Pcc 1:4:8 Type D-2, ( 40Mm Graded Stone Aggregate ) As In Sub Floor, Sub Bases, Floor And Paving Etc; Complete All As Specified. 25 M&L For Pcc 1:2:4 Type B0 25 Mm Thickusing 12.5Mm Graded Stone Aggregates As In Sub Floors / Base Floors Under Tiles As In Levelling Course Etc All As Specified And Directed. 26 M&L For Machine Cut Kota Stone Slab Flooring 18-20 Mm ( + 2Mm ) Thick Over Cement Screed Base Laid And Jointed With Greycement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Mirror Polishing Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:4 Complete All As Specified And As Directed. 27 M&L For Mirror Polished Machine Cut Kota Stone Slab 15-16 Mm Thick In Riser Of Steps, Skirting, Dado And Pillar Laid Over And Including 10Mm Thick Rendering In Cm 1:4 And Jointed Complete All As Specified And As Directed. 28 M&L For 16 -18Mm Thick Granite ( Colour As Approved ) Work ( Table Rubbed And Polished ) In Steps, Shelves, Jambs, Pillars, Window-Cills, Cooking Platforms ( Vertical / Horizontal ) And Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Over And Including 10Mm Thick Screed Bed Or Bedding Layer In Cm 1:4 Complete All As Specified And As Directed. 29 Cement Concrete ( 1:2:4 ) Type B-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, 50 Mm Thick, Surfaces Finished Even And Fair Without Using Extra Cement Including Provision Of Construction Joints Complete All As Specified. 30 Pressed Steel Framed Made Out Of 1.25Mm Thick Ms Sheet, Of Size 105X60mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate Etc, Complete All As Specified And Directed. 31 Cement Concrete ( 1:3:6 ) Type C-1 Using 20 Mm Graded Stone Aggregate As In Fillings And Mass Concrete, Filling Backs Of Chowkats Etc., Complete All As Specified 32 Cement Concrete ( 1:2:4 ) Type B-1 Using 20 Mm Graded Stoneaggregate As In Lintels Upto 1.50 M Clear Span, Cills , Steps, Seismic And Other Similar Bands, Copings, Kneelars, Apex Stones, Bed Plates, Bedblocks Of Hold Fasts Etc Including Necessary Form Work Complete All As Specified 33 S&F Of Factory Made 35 Mm Thick Plain Framed, Panelled Shutters ( Two Panel ) With 2Nd Class Hard Wood Rail And Stylewith Lock Rail And Panel Of 9 Mm B.W.P. Commercial Ply Or 12 Mm Veneered Particle Board With Commercial Veneering On Both Faces. The Size Of Rail And Stile As Per Is : 1003 ( Part I ) , Kiln Seasoned And Chemically Pressure Treated Complete All As Specified. 34 S&F Of Factory Made Steel Window Box Type Using Erw Hollow P Section Comprising Double Frame For And Including Gauged And Glazed Skeleton Shutter Jointed Internally With Flat Iron 40X4mm Complete Including Grill Of 8 / 10Mm Square Bars As Directed By Engineer Incharge, Fixed Horizontally @ 10Cm C / C, Hinges, Handle, Tower Bolts, Stops, Lugs Etc. ( With Provision Of Fixing For Cooler If Required ) All As Shown On Drawing No Cejz / Td / 20 Sheet 1 / 3 To 3 / 3 Fixed In Repairs I.E, Incl Taking Down And Removal Of Old Steel Windows From Site Or To Store Complete All As Specified And Directed. Note:- Guard Bar / Grillshall Be Measured And Paid Separately Under Respective Item Of Sch A. 35 S&F Of Sheet Glass Ordinary Quality 4 Mm Thick And Glazing With Oil Putty Or Fixed With Wooden Beads Or Fixed With Rubber Gasket In Squares Any Size Of Pane Complete All As Specified & As Directed. 36 Mild Steel Round Bars Welded To Steel Windows Or Ventilators As In Guard Bars Framed Or Unframed Complete All As Specified & As Directed By Engineer Incharge.Note:- Guard Bars Shall Be Factory Welded & Given One Shop Coat Of Red Oxide Or Zinc Chromate Primer. Cost Of Factory Welding & Shop Coat Of Primer Is Deemed To Be Included In Quoted Rates. 37 S&F Mild Steel Door Handles, Stove Enameled Black, 150 Mm Long And Fixed With Steel Screws Complete All As Specified. 38 S&F Of Mild Steel Barrel Tower Bolts, Stove Enameled Black, With Bright Bolt, 150 Mm Long And Fixed With Steel Screws Complete All As Specified. 39 S&F Of 300 Mm Long Mild Steel, Sliding Door Bolt, Plate Type, Stove Enameled Black, With Bright Bolt Not Less Than 12 Mm Dia With And Including Bolts And Nuts Complete All As Specified. 40 S&F Of Framed Work As In Doors Chowkats Of Ms Angle Iron Or Ms Hollow Square / Rectangular Any Type / Size With Gusset Plates, Rails, Braces, Cooler Stand, Chajja Framed Complete Drilled For Fixing Of Door Etc; To Be Prepared For Hanging With And Including Hold Fasts And Locking Arrangements Confirming To Fe- 290 ( Gde-E- 165 ) Complete All As Specified And Directed By Engineer-In-Charge. 41 M&L For 100Mm Thick Pcc 1:4:8 Type D-2, ( 40Mm Graded Stone Aggregate ) As In Sub Floor, Sub Bases, Floor And Paving Etc; Complete All As Specified. 42 M&L For 60Mm Thick Factory Made Pre Cast Cement Concrete Rubber Moulded Laquer Finish Using Chemical And Admixure Inter Locking Tiles Having Compressive Strength Not Less Than 350 Kg / Sqcm, Of Shape And Colour As Approved By Ge , Laid Over 25Mm Thickcompacted Approved Sand Cushioned Surface, Joints Filled By Fine Sand And Compacting The Top Surfaces Of Paver Blocks After Laid Etc Of Approved Make All As Specified And As Directed. 43 M&L For Factory Made Precast Cement Concrete Solid Blocks M-30 Grade, Using 20 Mm Graded Crushed Stone Aggregate As In Kerb Stones Of Any Size ( With Plain Or Interlocking Joints As Directed ) Set In Cement Mortar 1:4 For Path Edgings Etc; Embedded In Position Including All Necessary Excavation, Tamping Ground Arround Blocks And Removal Of Rubbish / Surplus Soil Etc., Complete All As Specified And Directed By Engineer-In-Charge. 44 M&L For Cement Concrete ( 1:2:4 ) Type B-1 Using 20 Mm Graded Stone Aggregate As In Kerbs Or Benching Etc Including Necessary Form Work Complete All As Specified. 45 Preparing New Plastered Surfaces And M&L For Applying Chalk Whitening / Concrete Primer And / Or Cement Base Putty As Required Incl Preparing The Surfaces Smooth By Rubbing And / Or Sandpapering And M&L Two Coats Of Distemper Oil Emulsion On New Plastered Surfaces All As Directed By Engr In Charge. 46 Preparing New Plastered Surfaces And M&L For Applying Concrete Primer And / Or Cement Base Putty As Required Incl Preparing The Surfaces Smooth By Rubbing And / Or Sandpapering And M&L Two Coats Of Cement Base Paint On New Plastered Surfaces All As Directed By Engr In Charge. 47 Preparation Of Newplastered Surfaces Of Ceiling Etc. & Applying Three Coats Of Limewhite Wash On Ceilingcomplete All As Specified. 48 Preparing New Or Previously Untreated Surfaces Of Wood And Wood Based Material Of Any Description Not Otherwise Described Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over One Coat Of Pink Primer Complete All As Specified And Directed. 49 Preparing New Or Previously Untreated Surfaces Of Steel Or Iron Work Of Any Description And Girth Over 10Cmand Applying Two Coats Of Synthetic Enamel Paint Complete All As Specified Andas Directed By Engineer-In-Charge.. 50 M&L For Point Wiring ( Concealed ) One Light / Fan Point Controlled By One 5 Amps One Way Switch With 1.5 Sqmm ( Nominal Area ) Copper Conductor Flame Retardant Low Smoke Cable ( Multi-Stranded ) Pvc Insulated And Unsheathed Electric Cable 1100 Volts ( Isi Marked ) Drawn Through Pvc Concealed Conduit Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Including Pvc Insulated Unsheathed Electric Cable 1100 Volts 1.5 Sqmm ( Multi-Stranded ) Copper Conductor Single Core ( Green Colour ) As Continuous Earth Wire Connected To Common Earth Dolly Including Metal Flush Box Made Out Of Ms With Hylum Sheet Suitable Size And Shape Complete All As Specified And Directed By Engineer-In-Charge.. 51 All As Per Item No 50 Above But For One 3 Pin Socket Outlet 5 Amps On Independent Board 52 All As Per Item No 50 Above But For One 3 Pin Socket Outlet 5 Amps On Same Board 53 All As Per Item No 50 Above But For One 3 Pin Socket Outlet 15 Ampsindependent With Cable Of Size 4.0 Sqmm For Point Wiring And 4.0 Sqmm In Continuous Earth Wire Complete All As Specified And Directed By Engineer-In-Charge. 54 S & F Switchpiano Type 1Way5a, 1 Module 240 Volts Complete All As Specfied And Directed By Engr-In-Charge. 55 S & F Switchpt 1Way15a, 1 Module, 240 Volts Complete All As Specfied And Directed By Engr-In-Charge. 56 S & F Socket, 6A - 2 / 3 Pin Combined 2 Module, Complete All As Specfied And Directed By Engr-In-Charge. 57 S & F Socket6a / 16A - 2 / 3 Pin Combined 2 Module, Complete All As Specfied And Directed By Engr-In-Charge. 58 S & F Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitable For Batten Fittings Complete All As Specified And Directed By Engr-In-Charge. 59 Supply And Fixing Led Lights Fitting 1X 18W, 220V Ac, Metal Ray Plus Is Made Of Extruded Aluminum Channel With Decorative Dual Color End Caps Providing A Glare Free Evenly Distributed Light With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. 60 Supply And Fixing Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With Pressure Die Cast Housing With Toughned Glass Ingress Protection Of Ip66, High Power Smd LedS And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete All As Specified. 61 Ceiling Rose Surface Backelite Isi Marked With 3 Terminalincluding Connecting And Testing Complete All As Specified And Dirted By The Engineer-In-Charge. 62 S&F Distribution Board Sheet Encloser Powder Coatedfor Mcbs With Bus Bar 250 Amps Rated And Neutral Link Earthing Stud And Degree Of Protection - Ip43 With Door / Mechanical Resistance Ik 07, Spn 8 Way 240 Volts Double Door, Concealed Flush To Wall Surface Complete All As Specified And Directed By The Engineer-In-Charge. 63 S&F Distribution Board Sheet Encloser Powder Coatedfor Mcbs With Bus Bar 250 Amps Rated And Neutral Link Earthing Stud And Degree Of Protection - Ip43 With Door / Mechanical Resistance Ik 07, Spn 4 Way 240 Volts Double Door, Concealed Flush To Wall Surface Complete All As Specified And Directed By The Engineer-In-Charge. 64 S& Mcb, C Curve Type, 10 Ka, 6 To 32 Amp, Single Pole With Over Load And Short Circuit Protection, Complete All As Directed. 65 S&F Mcb, C Curve Type, 10 Ka, 40Amp, Spn With Over Load And Short Circuit Protection, Complete All As Directed. 66 Supply And Fix Exhaust Fan, Steel Body Ac Single Phase. 230V Of Size 300M Sweep With, Blades, And Frame And Louvers With Necessary Making Hole And Finishing Work As Reqd At Site Complete All As Specified And Directed. 67 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, With 2 Module Electronic Step Type Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. 5 Star Rated With Brushless Direct Current Motor ( Bldc ) Compele All As Specified And Directed. 68 S&F Vertical Distribution Board, Double Door, Suitable For A Frame Fp Mccb 125A Made Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating, Vtpn 4 Way, 415 Volts With Bus Bar Rating 250 Amps, Dust And Vermin Proof, Suitable For Incorporation Of Mcb’S And Mccb Etc And Making All Necessary Connections, Concealed Flush To Wall Surface, Complete All As Specified And Directed. Note : Mccb & Mcb Will Be Measured And Paid Separately Under Respective Items 69 S&F Mccb, A Frame, Thermal Adjustable Magnectic Setting, Ics = 75% 25 Ka, 415V, 125 Amp, 4 Pole Mccb With Over Load And Short Circuit Protection, Complete All As Directed. 70 Supply And Fixing Concealed Sub Main Wiring With 2X10 Sqmm Single Core Copper Conductor ( Multistandered ) In Concealed Pvc Frls Conduit Of Suitable Size As Required, Including Single Core 6.0 Sqmm Copper Conductor As Earth Continuity All As Directed. 71 Supply, Laying, Testing And Commissioning Of Lt Ug Cable, Xlpe Insulated, Pvc Sheathed, Galvanized Steel Strip Armoured Electric Power Cable With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 35 Sqmm 3.5 Core Confirming To Is:7098 ( Part-I ) , Suitable For Earthed System, Laid In Duct / Trench / Along Pole / Wall Etc Including Nuts, Bolts, Washers, Saddles & Screws Etc And Making Connection, Complete All As Directed. 72 Supply, Laying, Testing And Commissioning Of Lt Ug Cable, Xlpe Insulated, Pvc Sheathed, Galvanized Steel Strip Armoured Electric Power Cable With Stranded Aluminium Conductor, 1100 Volts Grade Of Size 10 Sqmm 2.0 Core Confirming To Is:7098 ( Part-I ) , Suitable For Earthed System, Laid In Duct / Trench / Along Pole / Wall Etc Including Nuts, Bolts, Washers, Saddles & Screws Etc And Making Connection, Complete All As Directed. 73 Earthing Complete With Galvanized Steel Earth Plate Electrode 600X600x6mm Thickburied Directly In Ground ( Earth Pit Not Less Than 2..25 Mtr Deep Belownormal Ground Level ) With Top Edge Ofearth Plate Not Less Than 1.5 Mtr Below The Normal Ground Level, Earth Plate Surrounded By 15Cm Thick And Packed With Layers Of Charcoal Dust And Common Salt, Earth Lead Gi Wire 4Mm Dia ( 8 Swg ) Connectd To Gi Earth Plate Elcectrode By Means Of Bolts, Nuts, Check Nuts, Washers Of Galvanised Iron, Thimbles And Other End Of Earth Wire Connected To Main Switch Board And Protected By Galvanised Iron Pipe Medium Grade15mm Bore And20mm Bore Medium Grade Gi Pipewith Funnel And Wire Mesh For Watering All As Shown In Electrc Plate No 5 Connected To Earth Test Point.40Mm Thick Pre Cast Rcc M-15 ( Nominal Mix ) Cover Reinforced With Xpm Weight Not Less Than 4 Kg / Sqm With Suitable Handle Of 6Mm Dia Ms Bar And Angle Iron 40X40x3mm Frame For Cover, Pcc Chamber In Cement Concretem-15 ( Nominal Mix ) , Excavation And Earth Work In Any Type Of Soil And Connected All As Specified And As Directed By Engineer-In-Charge. 74 Supplying And Laying Un-Reinforced Precast Concrete Cable Cover, Class Lv, Type I, Flat, Size 250Mm X 150Mm X 40Mm Under Ground Cables For Protection 75 M&L For Sand Cushioning With Layer Of Sand 8Cm Thick Before Laying Of Cable And 10Cm After Laying Of Cable In Trenches Complete All As Directed And Sand Cover To Under Ground Cablecomplete All As Directed. 76 M&L Pipe Galvanised Iron Light Grade Complete With All Fittings Laid In Road Crossing, And On Pole, Buildings Complete All As Specified And Directed Isi Marked Of 40Mm Bore
|