Subscribe     Pay Now

Provision Of Otm Accn For Mdc Kamptee - Lump Sum Price Worked Out By The Contractor For B...


Contract Award Notice

TRR 7629362
Organization Military Engineer Services
Tender No CEBZ/KAM/TOKEN/18 OF 2021-22
Funded By Self-Funded
Country India , Southern Asia
Contract Value 31 Million

Work Detail

Provision Of Otm Accn For Mdc Kamptee - Lump Sum Price Worked Out By The Contractor For Building Work As Listed In Schedule ‘A’Part- I ( Ref Prepriced Schedule Attached Seperately ) 4 Lump Sum Price Worked Out By The Contractor For Internal Water Supplyas Listed In Schedule ‘A’Part- Ii ( Ref Prepriced Schedule Attached Seperately ) 5 Lump Sum Price Worked Out By The Contractor For Internal Electrification As Listed In Schedule ‘A’Part- Iii ( Ref Prepriced Schedule Attached Seperately ) 6 Lump Sum Price Worked Out By The Contractor For External Water Supply As Listed In Schedule ‘A’Part- Iv ( Ref Prepriced Schedule Attached Seperately ) 7 Lump Sum Price Worked Out By The Contractor For External Eletric Supply As Listed In Schedule ‘A’Part- V ( Ref Prepriced Schedule Attached Seperately ) 8 Lump Sum Price Worked Out By The Contractor For Road, Path & Culvert As Listed In Schedule ‘A’Part- Vi ( Ref Prepriced Schedule Attached Seperately ) 9 Lump Sum Price Worked Out By The Contractor For Area Drainage As Listed In Schedule ‘A’Part- Vii ( Ref Prepriced Schedule Attached Seperately ) 10 Lump Sum Price Worked Out By The Contractor For Sewage Disposal As Listed In Schedule ‘A’Part-Viii ( Ref Prepriced Schedule Attached Seperately ) 11 Lump Sum Price Worked Out By The Contractor For Security Fencing And Gate As Listed In Schedule ‘A’Part- Ix ( Ref Prepriced Schedule Attached Seperately ) 12 Lump Sum Price Worked Out By The Contractor For Fire Alarm System As Listed In Schedule ‘A’Part- X ( Ref Prepriced Schedule Attached Seperately ) 13 Lump Sum Price Worked Out By The Contractor For Air Conditioning, Cooling Appliances & Water Heater As Listed In Schedule ‘A’Part- Xi ( Ref Prepriced Schedule Attached Seperately ) 14 Lump Sum Price Worked Out By The Contractor For Lightning Protection As Listed In Schedule ‘A’Part- Xii ( Ref Prepriced Schedule Attached Seperately ) 15 Lump Sum Price Worked Out By The Contractor For Dg Set As Listed In Schedule ‘A’Part- Xiii ( Ref Prepriced Schedule Attached Seperately ) 16 Lump Sum Price Worked Out By The Contractor For Exacavation, Earth Work & Site Development As Listed In Schedule ‘A’Part- Xiv ( Ref Prepriced Schedule Attached Seperately ) 17 Sch A Pt - Xv ( Miscellaneous Items ) 18 Internalwater Supply Note:- For Items Of Internal Water Supply Notes Given At The Beginning Of Sch ‘A’ Part-Ii Shall Also Be Applicable. 19 S&F 2 In 1 Angle Cock Cum Bib Tap With Flange, 15Mm Bore Dia, Cast Copper Alloy, Chromiuim Plated, Fancy Type , Screwwed Down, High Pressure, With Crutch, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Complete All As Specified And Directed. 20 S&F 15Mm Bore Cp Urinal Spreader For Urinals And Fixed In Position Complete All As Specified And Directed. 21 Internal Eletrification Note:- For Items Of Internal Electrifications Notes Given At The Beginning Of Sch ‘A’ Part-Iii Shall Also Be Applicable. 22 M&L For Point Wiring Using Approved Colour Coding As Per Is ( Red, Black And Green For Single Phase Circuits ) , With Multi-Stranded Copper Conductor1.5 Sq. Mm Nominal Cross-Sectional Area, Single Core, Pvc Insulated And Unsheathedfrls Cable 1100 Volts Grade, Isi-694 Marked With Valid Cml No., Drawnin And Including Medium Grade, Rigid Pvc Concealed Conduit And Conduit Accessories Concealed In Wall / Roof / Floor Etc, Isi Marked With Valid Cml No. ( Is-9537-1983 For Conduits And Is:3419:1976 For Conduit Accessories ) , In Mild Steel / Pressed Steel Sunken Boxes ( With Earth Dolly ) With And Including Of 03Mm Thick Bakelite, Laminated Hylem Sheet Top Cover Of Suitable Size For Fixing Of Switches, Sockets And Fan Regulators Etc, Including Pvc Insulated Multi-Stranded Copper Conductor 1.5 Sq Mm Nominal Cross Sectional Area Single Core Frlscable As Earth Continuity Conductor To Common Earth And Connecting To Earth Dollycomplete All As Specified And Directed For The Following:- 23 One Light Point Point Controlled By One 5 / 6 Amps One Way Modular Switch. 24 One Ceiling / Exhaust Fan Point Controlled By One Modular Switch And Regulator. 25 One Bell / Buzzer Point Controlled By One Modular Bell Push. 26 One Light Point Controlled By Two5 / 6 Amps Two Way Modular Switchs. 27 One Socket Outlet, Three / Five Pin, 5 Amp, Controlled Byone 5 / 6 Amps One Way Modular Switch Or Modular Switch / Socket Combination 5 Amps, 5 Pin On The Same Board With Other Switches, Sockets, Fan Regulators, Etc. 28 One Socket Outlet, Three / Five Pin, 5 Amp, Controlled Byone 5 / 6 Amps One Way Modular Switch Or Modular Switch / Socket Combination 5 Amps, 5 Pin On Independent Board. 29 M&L For Point Wiring Using Approved Colour Coding As Per Is ( Red, Black And Green For Single Phase Circuits ) , With Multi-Stranded Copper Frlsconductor2.5 Sq. Mm Nominal Cross-Sectional Area, Single Core, Pvc Insulated And Unsheathedcable 1100 Volts Grade, Isi-694 Marked With Valid Cml No., Drawn In And Including Medium Grade, Pvc Concealed Conduit And Conduit Accessories Concealed In Wall / Roof / Floor Etc, Isi Marked With Valid Cml No. ( Is-9537-1983 For Conduits And Is:3419:1976 For Conduit Accessories ) With And Including Ms / Pressed Steel Sunken Box ( With Earth Dolly ) With And Including 3Mm Bakelite, Laminated Hylem Sheet Top Cover Of Suitable Size, Including Pvc Insulated Multi-Stranded Copper Conductor 2.5 Sq Mm Nominal Cross Sectional Area Single Core Cable As Earth Continuity Conductor To Common Earth And Connecting To Earth Dollycomplete All As Specified And Directed At Site For The One 3 / 5 Pin Amps 15 / 16 Amp Socket Outlet Independent Complete All As Specified And Directed. 30 S&F Led Lamp 9 / 10 W, Pin Type B 22, 230V Ac, 50Hz Single Phase Including Bakelite Batton Holder With All Fitting Fixing Accessories Complete All As Specified And Directed.Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 31 S&F Led Tube Light Fitting 20 W, 230V Made Of Aluminium Housingand Integrated Electronic Drivercomplete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed.Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 32 S&F Led Tube Light Fitting 18 W, 230V Made Of Aluminium Housingand Integrated Electronic Drivercomplete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed.Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 33 S&F Flat Panel 2 X 2 Surface Mounting 36W Led Luminiar For Glare Free Symmetric Soft Light With High Brightness Smd Leds And Min 4150 Lumenscomplete With All Accessories Including Driver Pre-Wired Complete All As Specified And Directed.Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 34 S&F Flat Panel 2 X 2, Recess Mountingled Luminaire Power Consumption Not More Then 36W, System Lumens Output 4250 Or Above, Cct5700k, Suitable For Armstrong / Grid Ceiling With High Brightness Smd Leds Complete With All Accessories Including Driver Pre-Wired Complete All As Specified And Directed.Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 35 S&F Led 10W Bulkhead Light Fitting With All Accessories Including Driver Pre-Wired Complete With All Fittings All As Specified And Directed. Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 36 S&F In Replacement Vtpn, 8 Way, Distribution Board, Double Door, Vertical Type Including Fixing And Connecting Of Mccbs / Mcbs / Isolator / Elcbs, Etc Factory Made, Confirming To Is: 13032 Fabricated Out Of Crca Sheet Not Less Than 1.2 Mm Thick Fitted With Din Channel, Neutral Link And 200 Amps 440 Volts Rated Bus Bar. Db Shall Be Semi Glossy Finished With Epoxy Polyester Based Powder Paint Sprayed And Baked At High Temperature, Between Powder Painting Process The Sheet Steel Having To Go Through The Anti-Rust Conditioning In Not Less Than Seven Tank Process To Ensure Smoothfinish And Protection Against Corrosive Atmosphere. The Db Shall Be Double Door Type With Hinged Door With Locking Arrangement. The Db Shall Be Of Same Make As Mcbs / Isolator. Db Shall Also Be Provided With Label Marking Indicating The Incoming And Outgoing Circuits. The Db Shall Be Of Ip 43 Protection Class Complete All As Specified And As Directed. Note:- Mccbs / Mcbs Shall Be Measured And Paid Seperatly. 37 S&Fled Street Light Fitting, Minimum Capacity Of25w, Made Up Of Pressure Die Cast Aluminium Housing With High Efficency Led As Lighting Source And Lens With Toughned Glass Having Bottom Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik 07, Etc And All Accessories Prewired With & Including Mounting Bracket Of 40Mm Bore Light Grade Pipe Of Required Length And Shape Including Bending, Forging Or Welding, Etc And Suitable Bolts, Nuts, Washeres, Etc And Connecting With Pvc Insulated Multi Stranded Copper Flexible Cable Of Size 0.5 Sqmm, Three Core From Ceiling Rose To Fitting Complete All As Specified And Directed. Notes: 1. Warranty For Replacement Of Each Led Shall Not Be Less Than 05 Yearsfrom The Date Of Purchase.2. Date Of Purchase Shall Be Marked On Each Fixture With Permanent Marker For Redeeming Warrenty Benifits. 38 S&F Mcb Spn, 40 Amp, 240 Volts Ac Confirming To Is: 13947-3 And Iec-60898 C Curve Type, Breaking Capacity 10 Ka Complete All As Specified And Directed. [ Qty = 12 ( Int Wiring ) + 1 ( Fire Alarm ) ] 39 S&F Mcb Spn, 6 To 32 Amp, 240 Volts Ac Confirming To Is: 13947-3 And Iec-60898 C Curve Type, Breaking Capacity 10 Ka Complete All As Specified And Directed. 40 S&F Mcb Sp, 6 To 32 Amp, 240 Volts Ac Confirming To Is: 13947-3 And Iec-60898 B Curve Type, Breaking Capacity 10 Ka Complete All As Specified And Directed. [ Qty = 106 ( Int Wiring ) + 4 ( Fire Alarm ) ] 41 S&F Mcb Sp, 40 Amp, 240 Volts Ac Confirming To Is: 13947-3 And Iec-60898 B Curve Type, Breaking Capacity 10 Ka Complete All As Specified And Directed. 42 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Galvanized Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No 3 Of Mes Ssr-2009 Part-I Connected To Main Switch Board Or Main Control Board All As Specified And Testing On Completion Including Provision Of Earth Wire Protected By 15Mm Dia Light Grade Gi Pipe And Watering Pipe Shall Be 20Mm Bore Light Grade Including All Excavation And Earth Work In Any Type Of Soil, Pcc Pit With Pre-Cast Rcc Cover With Handle Of 8 Mm Dia Bar, Charcoal / Salt, Funnel With Wire Mesh Etc Complete All As Specified And Directed.Note :- ( I ) The Concrete Pit ( To Be Provided Atleast 500Mm Away From Earth Pit ) Shall Be Pcc ( 1:3:6 ) Type C-1, 40 Mm Thick Pre Cast Cover Slab Of Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate Reinforced With 8Mm Tmt Bars @ 10 Cm C / C On Both Sides With Suitable Cast Iron Handle Shall Be Provided In Lieu Of Cast Iron Cover Shown In Electrical Plate No 3 Of Mes Ssr Part-I. ( Ii ) The Unit Rate Includes The Cost Of Gi Pipe Light Grade For Protection Of Earth Wire And 4Mm Dia Earh Lead Wire Upto 7.5 M. 43 S&F Telephone Rj 11 Socket, Modular Type, 1 Module With & Including Ms / Pvc Concealled Flush Boxcomplete All As Specified And As Directed. 44 S&F Lan Rj45 Socket, Modular Type, 1 Module With & Including Ms / Pvc Concealled Flush Boxcomplete All As Specified And As Directed. 45 M&L For 32 Mm Dia Pvc Conduit And Conduit Accessories, Concealed In Walls Complete All As Specified And Directed 46 External Water Supplynote:- For Items Of External Water Supply Notes Given At The Beginning Of Sch ‘A’ Part-Iv Shall Also Be Applicable. 47 M&L Forconstruction Of Brick Masonary New Valve Pit Chamber Of Following Size 100Mm Thick Pcc 1:4:8 Type D2 Lean Concrete Foundation Using 40Mm Graded Stone Aggregate Providing Well Burnt Brick Masonary Wall Of 23Mm Thick Built In Cm 1:6Rendering In Cement 1:6 Finished Even Smooth Using Extra Cement Internally And 20Mmthickin Cm 1:4And Finished Fair And Even Supply And Fix 3.15 Mm Thick Ms Sheet Steel Cover Fixed On 50Mmx50mmx6mm Thick Angle Ironframe Embbeded In Pcc Copingwith Locking Arrangement And 1 Nos 50Mm Size 4 Levers Lock With Key In Duplicate Standard Size And Ms Hold Fast And Handle Made Out Of 25 X 6Mm Flat Iron Appplyingtwo Coats Of Synthetic Enamel Paint Of Approved Shade Over A Coat Of Primer ( Red Oxide ) To All Exposed Surface Making Good All Disturbed Surface To Match Surrounding Complete All As Specified And Directed. 48 900 Mm X 900 Mm X 900 Mm Size 49 External Electric Supplynote:- For Items Of External Electric Supply Notes Given At The Beginning Of Sch ‘A’ Part-V Shall Also Be Applicable. 50 M&L For Earthing Complete With Galvanized Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Galvanized Earth Strip 32 X 6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No 3 Of Mes Ssr-2009 Part-I Connected To Test Point Or Main Switch Board Or Main Control Board All As Specified And Testing On Completion Including Provision Of Earth Strip Protection By 40Mm Dia Light Grade Gi Pipe And Watering Pipe Shall Be 20Mm Bore Light Grade Including All Excavation And Earth Work In Any Type Of Soil, Pcc Pit With Pre-Cast Rcc Cover With Handle Of 8 Mm Dia Bar, Charcoal / Salt, Funnel With Wire Mesh Etc Complete All As Specified And Directed.Note :- [ Qty = 2 ( Ext Electric ) + 4 ( Dg Set ) =6 ] ( I ) The Concrete Pit ( To Be Provided Atleast 500Mm Away From Earth Pit ) Shall Be Pcc ( 1:3:6 ) Type C-1, 40 Mm Thick Pre Cast Cover Slab Of Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate Reinforced With 8Mm Tmt Bars @ 10 Cm C / C On Both Sides With Suitable Cast Iron Handle Shall Be Provided In Lieu Of Cast Iron Cover Shown In Electrical Plate No 3 Of Mes Ssr Part-I. ( Ii ) The Unit Rate Includes The Cost Of 40Mm Gi Pipe Light Grade For Protection Of Earth Strip And 32 X 6 Mm Gi Earth Strip Upto 7.5 M. 51 S&F 120Mm Outer Dia & 108Mm Inner Dia Double Wall Corrugated High Density Polymer Ethyl ( Hdpe ) Pipe With Is 14930 ( Part 2 ) 2001 And 6Mm Wall Thickness; For Laying Of Electric Cable; Laid In Trenches, Wall, Floor, Pole Including Bends, Sockets And Other Connected Accessories Complete All As Specified And Directed. [ Qty = 75 ( Ext Electric ) + 70 ( Dg Set ) =145 ] 52 S&F 90Mm Outer Dia & 78Mm Inner Dia Double Wall Corrugated High Density Polymer Ethyl ( Hdpe ) Pipe With Is 14930 ( Part 2 ) 2001 And 6Mm Wall Thickness; For Laying Of Electric Cable; Laid In Trenches, Wall, Floor, Pole Including Bends, Sockets And Other Connected Accessories Complete All As Specified And Directed. 53 S&F 50Mm Outer Dia & 38Mm Inner Dia Double Wall Corrugated High Density Polymer Ethyl ( Hdpe ) Pipe With Is 14930 ( Part 2 ) 2001 And 6Mm Wall Thickness; For Laying Of Electric Cable; Laid In Trenches, Wall, Floor, Pole Including Bends, Sockets And Other Connected Accessories Complete All As Specified And Directed. 54 Design, Supplying, Installing, Testing And Commissioning Ltpower Distribution Feeder Pillar Panel Board, Outdoor, Double Door Ip - 65 Type Factory Fabricated Cubicaltype Weather Vermin Proof With Locking Arrangement And Made Out Of Ms Crca Sheet 3.15 Mm Thick Suitable Size Of Channel For Base Complete With 4 Nos- 400 Amps Rated Aluminium Bus Bar Inside Sepreate Chamberand Compartmentalised Cabinet For Housing Andmounting Mccbs, Metering Eqpt Prewired With Suitble Size Of Copper Conductor And Duly Powder Coated And Panel Board Fixing An Angle Iron Frame Which Is Made Out Of 50 X 50 X 6 Mm Thick Angle Iron Duly Marked The Incoming &Alloutgoing Controls And Comprising With The Following :- 55 Item No. 6.05 Contd.......Incoming:- ( A ) Bus Bar Chamber Comprising 4 Nos Aluminium Strip Bus Bars Air Insulated And Pvc Sheathed Capacity 400 Amps With Colour Coding In Separate Sheet Steel Enclosure. ( I ) Mccb 4 Pole 200 Amps 415 Volts 36 Ka - 01 No. ( Thermal Setting Adjustable Type 80 - 100% ( Ics-100% Icu ) With Connection Terminals. Outgoing:- ( B ) Mccb 4 Pole, 100 Amps 415 Volts 25 Ka - 02 Nos. ( Thermal Setting Adjustable Type 80 - 100% ( Ics-100% Icu ) With Connection Terminals ( C ) Mccb 4 Pole, 63 Amps 415 Volts 25 Ka - 02 Nos. ( Thermal Setting Adjustable Type 80 - 100% ( Ics-100% Icu ) With Connection Terminals ( D ) Mccb 4 Pole, 40 Amps 415 Volts 10 Ka - 02 Nos. ( Thermal Setting Adjustable Type 80 - 100% ( Ics-100% Icu ) With Connection Terminals ( E ) Multi Function Meter - 01 No ( F ) Phase Indicating Led Lamps ( R-Y-B ) -01 Set ( G ) Internal Wiring With Single Core Copper Conductor Cable / Pvc Insulated Copper Strip Of Suitable Size Incoming To Bus Bar And Bus Bar To Outgoing Mccb / Mcb-01 Job. ( H ) Fine Wiring With Single Core Copper Conductor Cable For Instruments / Indicating Lamps-1 Job. ( J ) Platform For The Feeder Pillar Board With Pcc 1:2:4 15 Cm Thick In Foundation, Brick ( Sub Class B ) / Stone / Pcc Blockwork Incm 1:6 , Rendering 1:6 On Exposed Surfaces And 100 Mm Thick Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate As In Padding On Top And Grouting Blots Etc For Panel . The Platform Shall Be Of 450 Mm Height Above Ground Level And Of Adequate Size Leaving Minimum 300 Mm All Around The Feeder Pillar Board For Movements. 56 S&F Led Bollard Fitting, Inverted Pyramid Tripod With Soft 360 Degree Lihgt And Ip-65 Protection Including Drivers, With All Accessories And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable Of Suitable Size Of 230V 50Hz From Fitting To Junction Box With & Including Necessary Ppc Work Type B-1 For Fixing Of Bollard And Formwork Complete All As Specified And Directed. 57 S&F Street Light Brackets Made Out Of Gi Tubing, Light Grade, 40 Mm Bore 1500Mm Long, Bent To Shape At 120 Degree, Fixed On Pole By Providing 2 Nos - Ms Clamp Made Up Of Flat Iron 30 X 5 Mm Including Bolts, Nuts And Washer Of Suitable Size Incuding Painting The Bracket & Clamp With Two Coats Of Aluminium Paint Over A Coat Of Primer Complete All As Specified And Directed. 58 S&F Thermoplastic Cable Junction Bos, Ip 55 / Ip 65 With Metric Knockout For Cable Entry Of Size 200 X 160 X 98Mm Fixing On Pole With 30 X 5Mm Ms Clamps, Nuts, Bolts, Washers, Terminal Block And Glands Suitable For 16 Sqmm Core Cable With & Including 1 No.- 6 Amps Mcb Spn 10Kacomplete All As Specified And Directed. 59 Road, Path & Culvertnote:- For Items Of Road, Path & Culvertnotes Given At The Beginning Of Sch ‘A’ Part-Vi Shall Also Be Applicable. 60 M&L For Road Line Painting 100Mm Wide With Golden Yellow / White Thermostatic Compound With Reflectorised Glass Beads On Bituminous Road, Providing And Laying Of Hot Applied Thermostatic Compound 2.5Mm Thick Including Glass Beads @ 250Gm Per Sqm Area Thickness 2.5Mm Is Exclusive Of Surface Applied, Glass Beads As Per Irc-35. The Finish Surface To Be Level And Uniform And Free From Streaks And Holes In Addition Where Arrows Or Letter To Be Provided Thermoplastic Compound May Be Hard Spalayed. The Colour Of Compound Shall Be As Directed Complete All As Specified And Directed. 61 S&F Solar Road Studs Of Size 125Mm X 125Mm X 20Mm, Aluminium Alloy And Polycarbonate Stud ( Red / Yellow Leds ) 3+3 Leds With Shank In Tough Aluminium Die Cast Body With Ms Zinc Coated Nails Of Size 12Mm Dia And 120Mm Long Complete As Per Morth / Irc Specifications And Directed. 62 Sewage Disposal Note:- For Items Of Dewage Disposal Notes Given At The Beginning Of Sch ‘A’ Part-Viii Shall Also Be Applicable. 63 M&L For Brick Masonry Septic Tank For 50 Users Designed To Carry Sewage And Sullage Water, Excavation In Any Type Of Soil, Pcc ( 1:4:8 ) Below Foundation, Base Slab, Buffle Walls And Precast Cover Slab Etc With Vent Shaft, Inspection Chamber Etc All As Specified And Shown In Drawing No. Cebz / Td / 76 / 2011 Sheet 1 / 2 & 2 / 2Complete All As Specified And Directed. 64 M&L For Site Soakage Well Of 1.8M Dia And 3Meffective Depth; Excavation In Any Type Of Soil, Foundation In Pcc 1:3:6, Wall Of Honey Combed And Solid Including Intercepting Chamber, Screen Chamber Brick Work In Cm, Rcc Cover Slab / Rr Masonry / Filling With Brick Bats All As Specified And Shown In Drawing No. Cebz / Td / 78 / 2011 Sheet 1 / 2 & 2 / 2 Complete All As Specified And Directed. 65 Fire Alarm Systemnote:- For Items Of Fire Alarm Systemnotes Given At The Beginning Of Sch ‘A’ Part-X Shall Also Be Applicable. 66 Supply, Installation, Testing And Commissioning Of Conventional Photo Electric Smoke Detectors Including Base Plate, Mounting Accessories Complete All As Specified And Directed. 67 Supply, Installation, Testing And Commissioning Of Manual Call Point Wall Recess / Surface Mounting, Dust & Vermin Proof, Intelligent Type, With &Including Additional Modules, Mounting Accessories And Ms Painted Outlet Box For Fixing Of The Station Complete All As Specified And Directed. 68 Supply, Installation, Testing And Commissioning Of Fire Alarm Hooter, Wall / Ceiling Recessed High Intensity Multi Tone Sounders Of Intensity As Mentioned In The Specification Including Ms Outlet Box For Fixing Of The Sounder, Mounting Accessories Complete All As Specified And Directed. 69 Supply, Installation, Testing And Commissioning Of 12 Zone Fire Alarm Panel, Wall / Surfcae Mounted, Conventional Fire Control Panel, 240V, Ac Power Supply Including Automatic Battery Charger, 24 Volts Sealed Batteries Sufficient For 48 Hours Normal Working And Be Capable Of Operating The System For 30 Minutes During Emergency Conditions, As Required Complete All As Specified And Directed. 70 Supply, Installation, Testing And Commissioning Of 12 Volts, 7 Ah Battery For Fire Alarm Panelcomplete All As Specified And Directed. 71 Air Conditioning, Cooling Applinaces & Water Heaternote:- For Items Of Air Conditioning, Cooling Applinaces & Water Heaterl Notes Given At The Beginning Of Sch ‘A’ Part-Xi Shall Also Be Applicable. 72 S&F Single Pole And Neutral Enclosure With Two Pin And Earth Plug And Socket Complete With & Including One Single Pole Mcb 20 Amp 240V Rupturing Capacity 10Ka C Series Complete All As Specified And Directed. 73 S&F 5 Kva Capacity Voltage Stabliser For Automatic Operation, Single Phase, Air Colled, Indoor Wall Mounted Type And Designed For Input Variation Between 170 Volts To 250 Volts, Otput Stablise Between 230 Volts With Accuracy Of + 2.5% Complete All As Specified And Directed. 74 S&F 3Kva Capacity Voltage Stabliser For Automatic Operation, Single Phase, Air Colled, Indoor Wall Mounted Type And Designed For Input Variation Between 170 Volts To 250 Volts, Otput Stablise Between 230 Volts With Accuracy Of + 2.5% Complete All As Specified And Directed. 75 Supply & Installed Refrigerator, Electric Driven ( Single Phase ) 230 Volts, Single Phase, 50 Hz, Bee Certified Minimum 4 Star Rating, Capacity Not Less Than 195 Litres, Frost Free Complete All As Specified And Directed. 76 Lightning Protectionnote:- For Items Of Lightning Protection Notes Given At The Beginning Of Sch ‘A’ Part-Xii Shall Also Be Applicable. 77 M&L For Earthing Complete With Galvanised Steel Pipe Electrode, 40Mm Bore, Medium Grade, 2.5 Metres Length, Buried Directly And Preferably Vertically In Ground With Top Edge Not Less Than 1.25 Metres Below Ground Level Connected With Copper Earth Strip 32 X 6Mm All As Shown Inplate No. 2 To The Earthing Test Point Or Main Switch Board Or Main Control Board All As Specified And Testing On Completion Including Provision Of Earth Strip Protection By 40Mm Dia Light Grade Gi Pipe And Watering Pipe Shall Be 20Mm Bore Light Grade Including All Excavation And Earth Work In Any Type Of Soil, Pcc Pit With Pre-Cast Rcc Cover With Handle Of 8 Mm Dia Bar, Charcoal / Salt, Funnel With Wire Mesh Etc Complete All As Specified And Directed.Note :- ( I ) The Concrete Pit ( To Be Provided Atleast 500Mm Away From Earth Pit ) Shall Be Pcc ( 1:3:6 ) Type C-1, 40 Mm Thick Pre Cast Cover Slab Of Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate Reinforced With 8Mm Tmt Bars @ 10 Cm C / C On Both Sides With Suitable Cast Iron Handle Shall Be Provided In Lieu Of Cast Iron Cover Shown In Electrical Plate No 3 Of Mes Ssr Part-I. ( Ii ) The Unit Rate Includes The Cost Of 40Mm Gi Pipe Light Grade For Protection Of Earth Strip And 32 X 6 Mm Copperearth Strip Upto 7.5 M. 78 Dg Setnote:- For Items Of Dg Set Notes Given At The Beginning Of Sch ‘A’ Part-Xiii Shall Also Be Applicable. 79 Supply, Installation Testing And Commissioning Of Oem Manufactured, Static Silent ( Sound Proof Enclosure ) , Disel Engine Driven Generating Set Capable Of Delivering 62.5 Kva, Water Cooled, 415 Volts ( Ac, 3 Phase, 4 Wire System Of Supply ) 50 Hz At Power Factor 0.8 Minium. The Dg Set Shall Consists Of Diesel Engine Coupled To A Matching Alternator Through Flexible Coupling And Mounted On Common Base Frame With Control Panel Standaedised By Manufacturer, Fuel Tank With Mounting Arrangements And Inlet Outlet Return Inlet Oil Arrangemnet, Exhaust Pipe Complete And Suitable For Conditions Prevelant At Kamptee ( Nagpur ) Including Pcc Foundation Of Suitable Size ( Leaving Atleast 0.5M All Round Space For Easy Of Movement And 0.5M Height ) Anti Vibration Pads, Including All Features With Latest Cpcb Guidelines And Comprising Of Following Complete All As Specified And Directed:- 80 Item No. 12.01 Contd / - ( I ) Engine ( Prime Mover ) : Diesel Engine 1500 Rpm, Direct Injection, Type Four Stroke, Confirming To Iso 3046 / Bs 5514, Water Cooled, Naturally Turbo Charged, Capable Of Giving Notless Than 83 Bhp To Drive Alternator Capable Of Delivering 62.5 Kva At Outdoor Atmospheric Conditions At Kamptee ( Nagpur ) , ( Taking All Derating Factor Into Consideration ) , 12 Volt ( As Permanufacturer Recommendations ) Electric Battery Start, Complete With Fly Wheel All Standardwithfittings / Fixtures As Per Manufacturer And Including Suitable Panel With Tachometer, Lubtemperature, Pressure Guage And Frequency Meters And Also Including Self Starter System, Dynamo, Fuel Electric Control Panel With Electronic Governor ( Ecpg ) And Engine Protection System ( Shut Down, High Water Temperature, Low Lub Oil, Oil Pressure, Over Speed Etc ) Fuel Tank And First Fill Of Lub Oil And Other Consumables Etc. ( Ii ) Alternator :Brushless Ac Alternator, 3 Phase, 415 Volt , 4 Wire, Rated To Drive 83Kva, Minimum Power Factor 0.8, 15000 Rpm, Ip 23 Protection Class Enclosure, Insulation Class “H” Salient Pole, Revolving Field Singlebearing Automatic Voltage Regulator Coupledthroughflexible Coupling With And To Match The Above Engine.Note: Alternator Capacity Calculated As Per Ambient Temperature 50 Degree Centigrade Of Nagpur Area. ( Iii ) Base Plate :- Made Out Of Structural Steel As Per Manufactures Recommended Design / Specifications. ( Iv ) In Built Amf Control Panal : Factory Made, Cubical Type, In-Built Amf Panel Borad, Indoor Type Made Out Of Ms Angle Not Less Than 25 X 25 X 5 Mm And 2 Mm Thick Ms Crca Sheet, Front Opening Type, Protection Class Ip-54, Duly Powder Coated After Seven Tank Process, Withelectrolytic Grade Copper Bus Bar Of 100 Amps Capacity For Four Poles, With All Standardswitchgear And Protection, Internal Wiring Of Adequate Size Pvc Insulated Multistranded Copperconductor Cable Etc And Also Consisting Of Following :- ( A ) Mccb, 100 Amp, 415 Volts Rating, 4 Pole, 25 Ka Rupturing Capacity, Specially Fixed For Incoming Supply With Over Load Relay, Short Circuit And Fault Protection – 01 No With Suitable Rating Hrc Back Up Fuses. ( B ) Amf Logic Panel Including Wiring, Power Contractor With Mccb Suitable Capacity For Dg Set Of Main Supply, Single Phase Preventor, Digital Multifunction Meter ( Showing Amps, Volts, Hz, Kwh Etc. ) Emergency Stop Button, Dgset Over Load, High Water Temp, Low Lub Oil Pressure, Auto Charging Unit And Failure To Start, Phase Indication Lamp Led Type Ryb Including All Relays, Circuit And Protection Required For Automatic Operation Of Dg Set. ( V ) Accousticenclosure :Sheet Metal Fabricated Cope Type, Silent Enclosure, Manufactured On Cnc Machines As Per Cpcb Norms And Powder Coated After Seven Tank Process; The Enclosure Shall Be Designed For Reducing The Sound Level To 75 Db ( A ) At A Distanceof 1 M At 75% Load Under Field Condition And Ox, 70 Db At 3 M From Gen Set When Dg Set Is Working At Full Load Alongwith Testing Conformance, Lebelling Certification Etc As Laid Down In Gsr No. 371 ( E ) Dt 17 May 2002. ( Vi ) Foundation / Plinth / Base : Shallbe Provided As Per Manufacturers Recommendations With Atleast 0.5M All Round Space For Easy Of Movement And 0.5M Height ( Minimum ) . ( Vii ) Diesel Storage Tank : Shall Be As Per Manufacturers Specifications. ( Viii ) Misc: Toolkit, Operation & Maintenance Catalogue, Spare Part List, Overhauling Manuals, Gurantee Card, Etc Shall Be Provided As Per Manufacturers Standard Practices Without Any Extra Cost To The Department. 81 Special Items 82 S&F Hospital Name Board Military Dental Centre Kamptee And In / Out In Stainless Steel Letters With Illumination ( 20 Cm Height Of Each Letter ) Withss Channel Edacrylic Letters; Back Sunboard Channel Letter, 3Mm Acrylic Sheetub A Cast, Laser Cutting And Solid Letter 10 With 3 M Vinyl Pasting; Water Proof, Wind Proof And Capable Of Withstanding Harsh Climatic Conditions Complete All As Specified And Directed. 83 S&F Modular Cabinet With Granite Counter Top, Lacquer Treated Mdf Door, Drawer With Handles / Knobs, Etc Complete All As Specified And Directed. 84 S&F 30Mm Thick First Class Hardwood Folding Partitions With Durable Finish, Study Design With Necessary Treatments, Etc Complete All As Specified And Directed. 85 S&F Polyster Blend Zebra Blinds For Windows As Approved By Ge Complete All As Specified And Directed. 86 S&F 25Mm High Density Polythelene Pipes Of Pressure Rating 6Kg / Sq Cm Laid On Walls, In Trenches, Etc Complete All As Specified And Directed.

Key Dates

Contract Date 20 Jun 2022

Contact Information

Company Name
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 2329257 SIBAL AND SIBAL INR 30523323.23
Contract Value 31 Million
Contract Date 20 Jun 2022

View Notice Now...

Login with your Social Account for Instant Access to this notice


Tell us about your Product / Services,
We will Find Tenders for you