Supply Installation Testing And Commissioning Of Public Address System And Fire Detection With Talk Back System For Surgical Block At Government Medical College, Kottayam - 1 Mr Supplying, Installing, Testing & Commissioning Of Voice Evacuation System For 20 Zones Expandable Up To 256 Zones . It Will Supports Upto 256 Zones Control And Management With Group Zone, Individual Zone And All Zone Separate Volume Control. Change-Over Switching Module ( 2 Nos ) With 20 Programmable Stem Node Or Wet Node Trigger Inputs And 20 Programmable On-Line Output Signal And Router To Provide Backup Amplifier Switching, Speaker Circuit Grounding Detection, Open Circuit & Close Circuit Detection, Compliant With En54, 20 Programmable Trigger Input And Output Interface, Support Power Save Mode, Support Line Redundance Wiring, Support Integration With Fire Alarm Controller, Frequency Response 80 Hz - 20 Khz, Distortion <1%, Power Consumption 48W, Protection Against Delay / Temp / Short / Overload. The System Include Built In Router, Voice Alarm Call Station And Voice Alarm Controller. Suitable For 20 Zones. ( System Include With Inbuilt Router ) 2 Mr Supplying, Installing, Testing & Commissioning Of 240W / 250W / 500W Rms One / Two Channel Class-D Power Amplifier With Switch Power Technology For Power Electricity Saving, Amplifier Shall Have Following Features: Supply Input Ac 220 + / - 10% - 50 / 60Hz, Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. Thd <0.1%, Frequency Response 20Hz - 20Khz, Ac & Dc Fuse, Snr >80Db. Announcement Points 3 Mr Supplying, Installing, Testing & Commissioning Of Pa Programmable 8 Zone Paging Microphone. Built In Hi-Fi Monitor Speaker With Monitor Output. With System Fault And Module System Status. 24V Dc Power Supply, Sensitivity 500Mv. 4 Mr Supplying, Installing, Testing & Commissioning Of Pa Programmable 8 Zone Extension Keypad. With System Fault And Module System Status. 24V Dc Power Supply, Sensitivity 500Mv. Speakers 5 Mr Supplying, Installing, Testing & Commissioning Of 6W Recessed Ceiling Speakers With Following Features:-Speaker Drive 6, Complete Aluminium Grille And Metal Baffle, Line Matching Transformer 100 / 70V Line. Variable Wattage Tappings Of 6 / 3 / 1.5, Effective Frequency Range 110-15Khz ( Bs6840 ) , Spl@1M / 1W=91Db, Peak Spl 97Db Complete With Necessary Mounting Hardware & Accesories. 6 Mr Supplying, Installing, Testing & Commissioning Of 10 / 12W Wall Mount Speaker With Frequency Response 150Hz - 15Khz, With Line Matching Transformer 100V. Variable Tapping 10W / 5W Or 12 / 6W, Spl@1M / 1W - 90Db, Peak Spl 98Db. Material Abs. Complete With All Necessary Hardware And Accessarios. 7 Mr Supply, Fitting, Fixing And Commissioning Of Dvd With Mp3 Player For Music System. 8 Mr Supplying, Laying, Testing And Commissioning Of 2C X 1.5 Sq.Mm. Armoured, Xlpe Insulated, Low Smoke Zero Halogen Inner And Outer Sheathed , Fire Survival Copper Conducter Cable. The Cable Shall Be Terminated In Devices And Control Panels By Using Suitable Sized Cable Glands And Lock Nut With All Accessories To Complete. 9 Mr Supply, Installation, Testring And Commisioning Of 22U Rack With Front Glass Door, Rear Perforated Door With Handle Lock & Key. Front / Rear 19 Mounting Angles, Top, Bottom Open, Ral 9005 With All Other Accessories B Fire Detection And Alarm System 10 1.21.2 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm 11 Mr Supply, Installation, Testing And Commissioning Of Ul Listed Approved Addressable Microprocessor Based Multicriteria Detector With Technology Having Responsivness Of Photoelectric, Thermal Along With Ul Listed Base. Themistor:Static / Fixed At 135°F ( 57°C ) And Rate-Of-Rise Detection At 15°F / Min. ( 8.3°C / Min. ) 12 Mr Supply Installation Testing & Commissioning Of Ul Listed Approved Duct Mounted Smoke Detector With Necessary Accessories For Fittings. 13 Mr Supply, Installation, Testing And Commissioning Of Addressable Microprocessor Based, Rate Of Rise And Fixed Temperature Heat Detector With Ul Listed Base. Field-Selectable Settings In The 57°C - 79°C Temperature Range And Can Be Configured To Provide A Low-Temperature Warning Signal At 40°F ( 4.4°C ) . 14 Mr Supply Installation, Testing & Commissioning Of Ul Listed Line Isolator For Isolating The Section Of Circuit Incase Of Short In The Addressable Loop Wiring. The Isolator Shall Not Carry Any Address To Optimise The Use Of Loop. 15 Mr Supply Installation, Testing & Commissioning Of Ul Listed Addressable Control Module With Built-In Isolator , Shall Meet Class X ( Style 7 ) Survivability Requirements , Have Multi-Color Light-Emitting Diode ( Led ) Which Indicates System Status And Shall Be Polarity Insensitive For Ahu & Stairs Pressurization Fan, Lift Etc. 16 Mr Supply Installation, Testing & Commissioning Of Ul Listed Addressable Monitor Module With Built-In Isolator , Shall Meet Class X ( Style 7 ) Survivability Requirements, Have Multi-Color Light-Emitting Diode ( Led ) Which Indicates System Status And Shall Be Polarity Insensitive For Sprinkler Flow Switch And Door Holders. 17 Mr Supply, Installation, Testing & Commissioning Of Response Indicator. 18 Mr Supply, Installation, Testing & Commissioning Ul Listed Manual Pull Station. Shock And Vibration Resistant, Pull Down Lever Remains Down Until Reset. And Shall Be Polarity Insensitive. 19 Mr Supply, Installation, Testing & Commissioning Of Ul Listed Hooter Cum Strobe With Field Selectable 15 / 30 / 75 / 110 Candela. 20 Mr Supply, Installation, Testing & Commisioning Of Ul Listed Graphics User Interface Software Package Of Same Oem Make For Complete Interactive Control Of The Fire Alarm System. Events Can Be Communicated Via E-Mail, Sms Via Mobile Phone. The System Shall Be Upgradable With A Multi-User Option / Client And Server Configuration Complete As Per Specifications And As Required. In The System, The Configuration Tool Shall Be Launched When The User Selects To Edit A Graphical Maps. The Systems Should Support Wide Variety Of Formats Such As Autocad, Pixel-Based Such As .Bmp And .Jpeg And Windows Metafiles. The Software Need To Provide Layer And Depth Control With Zoom Feature.The System Shall Also Confirm To The Ul Approvals. The System Shall Be Based On Client Server Architecture . Supplier Shall Provide Compatible Pc Specifiations. 21 Mr Supply, Installation, Testing And Commisioning Ul Listed Addressable Fire Alarm Panel Running On Full Digital Protocol With 32 Bit Microprocessor Based 20 Loop Panel Expandable To 40 Loops . The Panel Shall Be Complete With Liquid-Crystal Display ( Lcd ) Minimum 2X 40 Character, Alphanumeric Qwerty Type . Lcd Display Status Highlights Alarm Events . System Should Be Capable To Have Minimum 2500 Initiation Devices Per Panel In Any Combination . Each Addressable Loop Shall Be Capable Of Not Less Than 250 Addresses Per Loop Configuring Either As All Detectors Or Modules Or Any Mix Of Both. To Expedite System Troubleshooting, The System Cards Shall Have Ground Fault Detection And Diagnostic Leds By Card.Server Pc, 20 Inch Led Monitor And Laserjet Printer Shall Also Included In The Item. Building Floor Plan Can Be Loaded In Bitmap Or Jpeg Format, On The Map, The User Will See An Icon Indicating The Location Of The Event In The Building.The Panel Shall Support Degrade Mode Operation And Shall Have Battery Backup Of 24 Hrs In Normal Condition And 30 Minutes In Alarm Condition.. Panel Shall Have Interface Protocol Like Modbus, Backnet Or Any Other Similar Protocol To Interface With Bms.The Panel Shall Comply Ul Guidelines. Server Pc Of Min Core I3 Processor, 1Tb Hard Disk, Min 3 Ghz Processor, 500Gb Ram Suitable Graphics Card And Softwares To Monitor The Building Plan And Fire Alarm Events Using Gui.It Shall Be Possible To Do The Labeling Of Devices And Detectors By Hard Addresing Without Employing Special Tools From Oem. 22 Mr Supply, Installation, Testing & Commisioning Ul Listed Network Repeater Similiar To Main Fire Alarm Panel Shall Be Running On Full Digital Protocol With 32 Bit Microprocessor . 23 Supplying, Laying, Testing And Commissioning Of Projected Beam Detector Having Coverage Of 5M To 100M Including Transmitter And Reciver As Per Site Requirement With Addressable Module Complete As Required. 24 Mr Supplying, Laying, Testing And Commissioning Of 2C X 1.5 Sq.Mm. Armoured, Xlpe Insulated, Low Smoke Zero Halogen Inner And Outer Sheathed , Fire Survival Copper Conducter Cable. The Cable Shall Be Terminated In Devices And Control Panels By Using Suitable Sized Cable Glands And Lock Nut With All Accessories To Complete. C Talk Back System 25 1.21.2 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm Controller 26 Mr Sitc Of 60 Zone Talk Back Console With Built-In Evacuation Message, Also Built-In With Inbuilt / External Amplifier. To Be Placed In Fire Control Room. The Panel Shal Have Display To Show The Caller Id & Location The Panel Shall Have Provision For Inbuilt Or External Microphone To Have A Two Way Talk Back Communication With Field Unit. Talk Back Unit 27 Mr Sitc Of Addressable Emergency 5 Watt Speaker, With Built-In Microphone, Which Shall Give 90Db Output, Speakers, Wall Mounted Type ( Talk-Back Speaker, Push Button ) . It Shall Provide Different Indication For Normal Condition & Alarm Condition. 28 Mr Supplying, Laying, Testing And Commissioning Of 2C X 1.5 Sq.Mm. Armoured, Xlpe Insulated, Low Smoke Zero Halogen Inner And Outer Sheathed , Fire Survival Copper Conducter Cable. The Cable Shall Be Terminated In Devices And Control Panels By Using Suitable Sized Cable Glands And Lock Nut With All Accessories To Complete. 29 Mr Supply, Installation, Testring And Commisioning Of 6U Rack With Front Glass Door, Rear Perforated Door With Handle Lock & Key. Front / Rear 19 Mounting Angles, Top, Bottom Open With All Other Accessories
|