Generator Supply And Installation For Panchayath Office Building Generator Supply And Installation For Panchayath Office Building , Electrical , 90.2.1.1 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988, Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1.00 Sq Mm Frlspvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper, Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates ( White ) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. ( Rohs Compliant Modular Accessories ) . , 90.3.20.3 : Supply & Installation Of Light Fittings On Tw Round Block Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required. , 90.6.10.1 : Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required , 90.6.10.2 : Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required , 90.12.1.12 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , 90.12.1.41 : Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering ( In Ordinary Soil ) . , 90.12.7.12 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. , 90.12.7.41 : Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required. , Od1435402 / 2021_2022 : Supply&Amp; Clamping Control Copper Cable Pvc Insulated 2.5Mm2 X8 Core On Wall As Required And Giving Connections. , 9.1.33 : Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm ( 28Mm ) , 1.24.3 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch , 1.24.5 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet , 1.27.2 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) , 90.11.1.19 : Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper / Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb / Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required , 2.2.1 : Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.100 Amp, 16 Ka, Tpmccb , 2.15.3 : Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.10.4 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , 5.4 : Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, Andproviding Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , 90.16.1.5 : Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required , 90.16.5.5 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. , 90.16.5.6 : Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. , 14.1 : Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.7 : Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.9 : Providing And Laying In Position Cement Concrete 1 :3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , 14.12.1 : Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) At All Levels. , Od1435413 / 2021_2022 : Supply , Conveyance, Installation, Testing And Commissioning Ofthree Phase 25Kva Dg Setwith Amf Panel &Amp; It&Apos;S Standard Accessories , Battery And Other Accessories With Approved Kg Canopy As A Complete Set Including First Fill Of Lube Oil &Amp; Engine Oil &Amp; Engine Safeties And All Other Standard Accessories Including Cpcb Approved Acoustic Enclosureetc.As Required. Kirloskar / Asokleyland / Koel / It&Apos;S Equivalent Make With Fittings As Detailed Below.Engine.1.&Nbsp;&Nbsp;&Nbsp; Flywheel And Flywheel Housing≪Br≫2.&Nbsp;&Nbsp;&Nbsp; 12 V Dc Electric Start Arrangement≪Br≫3.&Nbsp;&Nbsp;&Nbsp; Exhaust Silencer &Ndash; Residential Type Silencer≪Br≫4.&Nbsp;&Nbsp;&Nbsp; Fuel Filter ( Pre And Micro ) ≪Br≫5.&Nbsp;&Nbsp;&Nbsp; Lube Oil Filter &Ldquo;Spin-On&Rdquo; Type≪Br≫6.&Nbsp;&Nbsp;&Nbsp; Radiator ( For Liquid Cooled Dg Set Only ) ≪Br≫7.&Nbsp;&Nbsp;&Nbsp; Dry Type Air Cleaner≪Br≫8.&Nbsp;&Nbsp;&Nbsp; Battery Charging Alternator ≪Br≫9.&Nbsp;&Nbsp;&Nbsp; Fuel Hoses≪Br≫10.&Nbsp; Maintenance Manual And Spare Parts Catalogue≪Br≫11.&Nbsp; Radiator Fan ( For Liquid Cooled Dg Set Only ) ≪Br≫12.&Nbsp; Fuel Injection Pump With Mechanical Governor And Fuel Feed Pump≪Br≫13.&Nbsp; Closed Coupled Engine With Inbuilt Anti Vibration Mounting Pads≪Br≫14.&Nbsp; First Fill Of Lube Oil≪Br≫15.&Nbsp; First Fill Of Coolant ( Life Is 3000 Running Hours Or 3 Years ) ≪Br≫Alternator≪Br≫Koel Make Self &Ndash; Excited, Self &Ndash; Regulated, Screen Protected, Drip Proof Alternator With Static Excitation System, Capable Of Developing Rated Output At 415V, 0.8 P.F. 50 Hz When Running At 1500 Rpm At Ntp Conditions And Conforms To The Is 4722 Standards.≪Br≫ Control Panel Consisting-Genset Controller Having Alternator Parameter Like Voltage, Frequency, Amps, Kw, Kvar, Pf Etc., 3 Nos Current Transformer.Kw Hour Meter, Alu. Bus Bar, Indication Lamps, Mcb, Instruments Fuses , Earthing Studs. Amf Panel- Auto Start Stop Panel &Amp; Battery Charger.Etc. , Od1435338 / 2021_2022 : Supply &Amp; Laying / Clamping 25X3mm Gi Strip In Position As Required. , 5.14 : Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Od1435339 / 2021_2022 : Aluminium Anodised Danger Notice Board Of Size 150 X 100 Mm. With Inscriptions ( Both In English And Malayalam ) Andconventional Skull And Bone In Red Colour.≪Br≫ , Od1435340 / 2021_2022 : Charges For Preparing Schematic Diagrams For Initial &Amp; Final Approval For Submitting Electrical Inspectorate , Od1435341 / 2021_2022 : Chargesfor Remitting Required Amount Of Inspection Fee , Initial &Amp; Final Approval Charges To Electrical Inspectorate. Actual Amount Reimbursed Producing Original Bills , Od1435342 / 2021_2022 : Painting Letters Or Figures Of The Following Sizes With Enamel Paint As Identification Mark To Sb, Db, Panel Board Etc As Required.2.5 X 4 Cm ≪Br≫ , Od1435343 / 2021_2022 : Supply And Providing First Aid Chart Duly Framed And Placed In A Conspicuous Location For Clear Vision.≪Br≫ , Od1435344 / 2021_2022 : Supply And Providing 2Mm Thick Elastomeric Fire Retardent Insulating Mat As Per Is 15652 / 2006 To Withstand 3.3 Kv Dielectric Strength. ≪Br≫ , Od1435345 / 2021_2022 : Supply And Providing Extra Length Of Heavy Duty Ms Pipe 65Mm Dia. / Nearest Size With Suitable Angle Iron Support As Required. , Od1435346 / 2021_2022 : Supply And Providing 9 Litre Capacity Gi Fire Bucket Painted In Post Office Red With Primer Coat Of Red Oxide And Written With White Paint &Apos;Fire&Apos; Mounted On Ms Angle Frame Work / Wall Bracket Filled With Fine Sand, Painting The Bracket / Floor Stand Including Making Good The Damages, Colour Washing Etc. As Required.≪Br≫ , Od1435347 / 2021_2022 : Supplying And Installation Of Supports, Anchor Bolts Etc Made Out Of Suitable Size Single Section Ms Angle, Flats Etc As Required Including Painting With 2 Coats Of Synthetic Enamel Paint≪Br≫ , Od1435348 / 2021_2022 : Reinforcement For R.C.C Works, Bend Tied And Placed In Position ( Plain Grill Requiring Bend Cold ) Using Tor Steel ≪Br≫ , Od1435349 / 2021_2022 : Supplying, Laying And Jointing Of 40 / 32 Mmm Dia. / Nearest Size Of Double Wall Corrugated ( Dwc ) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories Clamping In Position. , Od1435362 / 2021_2022 : Supply And Providing 5 Kg. Dry Chemical Powder Type Fire Extinguisher With Hose And Clamps Including Fixing It To Wall As Required. , Od1435421 / 2021_2022 : Supply And Providing 25X6 Mm Brass Bolt And Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , Od1435428 / 2021_2022 : Supply Diesel For Dg 1St . Test Running &Amp;Load Checking.
|