Amc ( Non Comprehensive ) Of Window , Split And Cassete Ac Amc ( Non Comprehensive ) Of Window , Split And Cassete Ac , Part A , Annual Maintenance Contract ( Non-Comprehensive ) Of 1 / 1 . 5 / 2 Tr Window Ac Installed At Iit Roorkee And Greater Noida Campus Including Re-Filling Of Gas Whenever Required For Proper Cooling . Minimum Two Service In A Year And Unlimited Call Breakdown Will Be Part Of The Contract . , Annual Maintenance Contract ( Non- Comprehensive ) Of 1 / 1 . 5 / 2 Tr Split Ac Including Indoor And Outdoor Unit Installed At Iit Roorkee And Greater Noida Campus Including Re-Filling Of Gas Whenever Required For Proper Cooling . Minimum Two Service In A Year And Unlimited Call Breakdown Will Be Part Of The Contract . , Annual Maintenance Contract ( Non- Comprehensive ) Of 3 . 0 Tr Cassete Ac With Indoor And Outdoor Unit Including Re-Filling Of Gas Whenever Required For Proper Cooling , Installed At Conference Hall , Kih , Iit Roorkee . Minimum Two Service In A Year And Unlimited Call Breakdown Will Be Part Of The Contract . , Comprehensive Annual Maintenance Contract Of 8 . 5 Tr Ductable Split Ac Including Indoor And Outdoor Unit Installed At Senate Hall , Iit Roorkee . This Contract Covers Attending To Any Number Of Breakdown Calls During Normal Working Hours Except For All National / Public Holidays . A Quarterly Preventive Maintenance Service Has To Be Carried Out During The Tenure Of The Contract . All Parts Including Compressor , Pwb , Sensor Which Requires Repair / Replacement Due To Normal Wear And Tear During The Contract Shall Be Replaced Free Of Cost . Including Replacement Of Essential Spares , Re-Filling Of Gas Whenever Required For'''' Proper Cooling . Minimum 4 Services In A Year And Unlimited Call Breakdown Will Be Part Of The Contract . This Contract Does Not Cover The Repair / Replacement Of , Electricity Distribution Boards , Mccb / Mcb / Elcb , Ancillary Work Such As Ducting / Masonry Work , Cabinet Sheet Metal Panels , Shifting Of Units In Part Or As A Whole . , Part-B ( Supply & Fixing Of Spares Required During Maintenance Period . ) , Window Type Air Conditioner , Supply & Replacement Of Reciprocating Compressor For 1 . 0 Tr Window Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Rotary Type Compressor For 1 . 5 Tr Window Ac Including Gas Refifling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Rotary Type Compressor For 2 . 0 Tr Window Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply Of Pcbs For 1 . 0 / 1 . 5 / 2 Tr Window Ac , Supply & Replacement Of Cooling Coil For 1 . 0 Tr Window Ac , Supply & Replacement Of Cooling Coil For 1 . 5 Tr Window Ac , Supply & Replacement Of Cooling Coil For 2 . 0 Tr Window Ac , Supply Of Remote For 1 / 1 . 5 / 2 Tr Window Ac , S& F Of Fins Swing Motor For 1 / 1 . 5 / 2 Tr Window Ac , S& F Of Fan Motor For 1 / 1 . 5 / 2 Tr Window Ac , S & F Of Fan Blade 1 / 1 . 5 / 2 Tr Window Ac , Supply & Replacement Of Blower For 1 . 0 / 1 . 5 / 2 Tr Window Ac , S & F Of Water Collecting Tray For 1 . 0 / 1 . 5 / 2 Tr Window Ac , S / Installation Of Sensor ( Air & Coil ) For Window Ac . , S / Installation Of Condensing Coil For Window Ac . , Removal Of 1 . 0 / 1 . 5 / 2 Tr Window Ac , Installation Of 1 . 0 / 1 . 5 / 2 Tr Window Ac , Split Air Conditioner , Supply & Replacement Of Reciprocating Type Compressor For 1 . 0Tr Split Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Of Reciprocating Type Compressor For 1 . 5 Tr Split Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Of Rotary Type Compressor For 1 . 5 Tr Split Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Of Rotary Type Compressor For 2 Tr Split Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Of Reciprocating Type Compressor For 2 Tr Split Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Cassette Ac , Supply & Replacement Of Rotary Type Compressor For 3 . 0Tr Cassette Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Supply & Replacement Of Rotary Type Compressor For 1 . 5 Tr Cassette Ac Including Gas Refilling . No Separate Charge Will Be Paid For Gas . , Others , Supply Of Pcbs For 1 . 0 / 1 . 5 / 2 Tr Split Ac , Supply & Replacement Of Cooling Coil For 1 . 0 / 1 . 5 / 2 Tr Split Ac Cooling Coil , Supply Of Remote For 1 / 1 . 5 / 2 Tr Split Ac , S &F Of Fins Swing Motor For 1 / 1 . 5 / 2 Tr Split Ac , S&F Of Fan Motor Of Indoor Unit For 1 / 1 . 5 / 2 Tr Split Ac , Supply & Replacement Of Fan Motor Of Outdoor Unit For 1 / 1 . 5 / 2 Tr Split Ac , S & F Of Fan Blade For 1 / 1 . 5 / 2 Tr Split Ac , Supply & Replacement Of Fan Blower For 1 / 1 . 5 / 2 Tr Split Ac , Supply & Replacement Of Insulation , Supply , Installation , Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft / Hard Drawn Copper Refrigerant Piping For Ac System , Complete With Fittings , With Sultable Adjustable Ring Type Hanger Supports , Jointing / Brazing Including Accessories , Insulated With Xple Class-O Tubular Insulation / With Class-O Closed Cel ) Elastomeric Nitrile Rubber Tubular Sleeves Sections Of Specified Thickness As Given Below For Suction And Liquid Lines , All Accessories As Per Specifications Etc . As Required : , 6 . 4 Mm Dia ( Od ) ( Soft Drawn ) With Tube Thickness 1 . 2 Mm With 19 Mm Thick Insulation . , 9 . 5 Mm Dia ( Od ) ( Soft Drawn ) With Tube Thickness 1 . 2 Mm With 19 M M Thick Insulation , 12 . 7 Mm Dia ( 0D ) ( Soft D Rawn ) With Tube Thickness 1 . 2 Mm With 19 Mm Thlck Insulation , 15 . 86 Mm Dia ( 0 D ) ( Soft Drawn ) With Tube Thickness 1 . 2 Mm Wlth 19 Mm Thick Insulation , 19 Mm Dia ( Od ) ( Hard Drawn ) With Tube Thickness 1 . 2 Mm With 19 Mm Thick Insulation , 22 . 2 Mm Dia ( Od ) ( Hard Drawn ) With Tube Thickness 1 . 2 Mm With 19 Mm Thick Insulation , 28 . 58 Mm Dla ( Od ) ( Hard Drawn ) With Tube Thickness 1 . 2 Mm With 19 M M Thick Insulation , Supply & Fixing Of 50 Mm Wide Pvc Channel Capping For Covering Over Outdoor Piping , S / Installation Of Sensor ( Air & Coil ) For Split Ac . , S / Installation Of Contactor For Split Ac . , S / Installation Of Condensing Coil Of Outdoor Unit For Split Ac . , Denting Of Outdoor Unit For Split Ac , Painting Of Outdoor Unit For Split Ac , Removal Of 1 . 0 / 1 . 5 / 2 . 0 Tr Split Ac , Installation Of 1 . 0 / 1 . 5 / 2 . 0 Tr Split Ac , S / F Of Running Capacitor - 36 Mfd . , S / F Of Running Capacitor - 45 Mfd . , S / F Of Running Capacitor - 50 Mfd . , S / F Of Running Capacitor - 55 Mfd . , S / F Of Running Capacitor - 60 Mfd . , S / Installation Of Thermostat Switch . , S / Installation Of Selector Switch . , S / Installation Of Suction Valve - 1 / 2Inch . , S / Installation Of Suction Valve - 1 / 3Inch . , S / Installation Of Suction Valve - 5 / 8Inch . , S / Installation Of Discharge Valve - 1 / 4Inch . , Supply & Replacement Of Floor / Wall Stand For Outdoor Unit , S / Installation Of Smart Contactor ( Ac Timer ) , Supply / Fixing Of 25 Mm Pvc Isi Marked Medium Duty ( Upto 10 Kg . Ps ) Drain Pipe Make :Finolex / Astral / Supreme , Supply / Fixing Of 3 Core 2 . 5 Sq . Mm
|