supply installation testing and commissioning Of Microprocessor Based Fire Alarm Control Panel With Allied Works Of Main Building Annex Building At Uttarkanya Kamrangaguri In The District Of Jalpaiguri . , supply , installation , testing & commissioning of en/ul standard , fm/vds approved microprocessor based fire alarm control 4 loop ( up to 8 loop expandable ) panel fully networkable ( vender should consider network card for panel to panel networking ) with each loop capable of taking at least 250 devices and each loop should be connected to a dedicated loop card ( even if a loop card supports multiple loop the panel should be provided with 4 nos loop cards and should have provision for accommodating total 8 nos loop card ) , 114 vga display character alpha-numeric liquid crystal display . the panel shall be soft addressable type . the panel shall be able to give pin point location of all fire/fault conditions . further , the panel must be able to automatically switch off respective control switches whenever any alarm is triggered . the panel shall have in built rectifier , provision for external & internal printer ( if required ) , loop cards , l c d unit to indicate fire/fault signal with address and analogue output , complete in all respects , having minimum 1000 event memory , integral smf lead acid batteries with sealed cells of 24 v 112 v with integral battery charger complete as required and as per specification . ( approved make- honeywell by moreley or notifier/siemens ) , supply , drawing , designing , installation , testing & commissioning of analogue addressable intelligent multisensory detector with two in built optical smoke sensor with backward & forward scattering light angles as well as additional heat detector sensors with decentralise intelligence , soft addressable photo thermal type with inbuilt fault isolator as per nfpa style wiring complete with base as required ( approved make-honeywell by moreley or notifier/siemens ) . , supply , drawing , designing , installation , testing & commissioning of analogue addressable intelligent heat detector with fixed & rate of rise temperature function with decentralise intelligence , soft addressable type with inbuilt fault isolator as per nfpa style wiring complete with base as required . ( approved make-honeywell by moreley or notifier/siemens ) . , supply , drawing , designing installation , testing & commissioning of addressable manual call point soft addressable type with inbuilt fault isolator as per nfpa style 7 wiring complete as required . ( ( approved make-honeywell by moreley or notifier/siemens ) . , supply , drawing , designing installation , testing & commissioning of addressable loop powered hooter ( sound output of minimum 90 db ) cum strobe ( strength of light 10cd ) complete with inbuilt isolater & ip65 base and as required . ( approved make:honeywell-esser/siemens/securiton ) manual call point soft addressable type with inbuilt fault isolator as per nfpa style 7 wiring complete as required . ( approved make-honeywell by moreley or notifier/siemens ) . , supply drawing designing and laying of 2 core 1 . 5 sqmm frls shield copper cable ( for loop ) make-filolex/techno flex/mem with 20mm nb pvc rigid conduit pipe on the surface of the wall , or cable tray on ceiling . , servicing and repairing of existing fire panel ( addressable ) and reinstallation the same and have to be functioning all fire alarming system in all buildings as per e-i-c . , operation and maintenance the whole fire detecting systemm of all buildings at uttarkanya including sufficient tools & tackles and expert technician of similar nature of works . attend any type of breakdown and restore that in same day or as per direction of e-i-c . [log book to be maintained and submitted to the e-i-c] .
|