Contract Award For Itq For A Three-Year Term Contract For The Servicing And Maintenance Of Equipment In Singapore Botanic Gardens Laboratories And Seed Bank. . B(Vi) Molecular Laboratory _To Provide Labour, Materials & Test Instrument To Carry Out The Servicing Requirement For One Unit Of Agilent 4200 Tapestation , A(I) Tissue Culture Laboratory_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Laminar Flow Cabinet _A) Airflow Velocity Test ( 4 Times A Year For 11 Units Of Laminar Flow ) , A(I) Tissue Culture Laboratory_Laminar Flow Cabinet _ To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Laminar Flow Cabinet _B) Particle Count Test ( 2 Times A Year For 11 Units Of Laminar Flow ) , A(I) Tissue Culture Laboratory_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Rooms Of Laboratory _C) Particle Count Test @ 0.5Um For Culture Room (10 Sample Points) ( 2 Times A Year) , A(I) Tissue Culture Laboratory_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Rooms Of Laboratory _ D) Particle Count Test @ 0.5Um For Shaker Room (4 Sample Points) ( 2 Times A Year) , A(Ii) Tissue Culture Laboratory_ A)Hepa Filter ( 1220 X 610 X 66 Mm ) For Esco Cabinet , A(Ii) Tissue Culture Laboratory_ B) Hepa Filter ( 910 X 610 X 66 Mm ) For Quest Cabinet , A(Ii) Tissue Culture Laboratory_ C) Uv Lamp ( 3 Feet ) For Esco Cabinet , A(Ii) Tissue Culture Laboratory_ D) Fluorescent Lamp, Cool Daylight( 4 Feet ) For Esco Cabinet , A(Ii) Tissue Culture Laboratory_ E) Fluorescent Lamp, Cool Daylight (3 Feet ) For Quest Cabinet , A(Ii) Tissue Culture Laboratory_ F) Side See Through Polycarbonate Cover - 545 X 695 X 5 Mm , A(Ii) Tissue Culture Laboratory_ G) Castor Wheels , A(Ii) Tissue Culture Laboratory_ H) Pre-Filter - 20M X 2M X 10Mm , A(Ii) Tissue Culture Laboratory_ I) Acrylic Sheet - 145 Cm X 58 Cm X 5Mm , A(Ii) Tissue Culture Laboratory_ J) Acrylic Sheet - 84 Cm X 45 Cm X 5Mm , A(Ii) Tissue Culture Laboratory_ K) Acrylic Sheet - 85 Cm X 60 Cm X 5Mm , A(Ii) Tissue Culture Laboratory_L) Acrylic Sheet - 35.5 Cm X 45.5 Cm X 2Mm , B(Iii) Molecular Laboratory_ To Provide Labour, Materials & Test Instrument To Carry Out The Servicing Requirement For One Unit Of Bio-Safety Cabinet (Bsc) (Nuaire Model:Nu-425-400E) With Fumigation Inclusive Of Preventive Maintenance (Once Per Year) , B(Iv) Molecular Laboratory_A) Fluorescent Lamp , B(Iv) Molecular Laboratory_B)Uv Lamp , B(Iv) Molecular Laboratory_ C) Hepa Filters I.E. Downflow And Exhaust Filter Per Set , B(Iv) Molecular Laboratory_ D) Fumigation Cost Required For Changing Of Hepa Filters , C(Vii)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_ (Model: Bigneat & Bp8004/11A (Xit 804 Powder Weighing Enclosure)_Airflow Velocity Test (1 Time A Year ) , C(Vii)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_ (Model: Bigneat & Bp8004/11A (Xit 804 Powder Weighing Enclosure)_Particle Count Test (1 Time A Year ) , C(Viii)Seedbank_A) Hepa Filter (L 755 X W 405 X Thickness 50 Mm) , C(Viii)Seedbank_B) Pre-Filter (L 755 X W 405 X Thickness 10Mm) , C(Viii)Seedbank_C) Led T8 Tube, Daylight (410 Mm) , C(Ix)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Ductless Fumehood (Model: Advance Lab & Ad04fh-Dc (4Ft), Serial No.: Ad04fh-Dc-00081/19)- Airflow Velocity Test (1 Time A Year ) , C(Ix)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Ductless Fumehood (Model: Advance Lab & Ad04fh-Dc (4Ft), Serial No.: Ad04fh-Dc-00081/19)- Smoke Test (1 Time A Year ) , C(Ix)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_Ductless Fumehood (Model: Advance Lab & Ad04fh-Dc (4Ft), Serial No.: Ad04fh-Dc-00081/19)- Replacement Of Filter (1 Time A Year ) , C(X)Seedbank_A) Aluminium Carbon Filter (L 600 X W 400 X Thickness 20Mm) , C(X)Seedbank_B) Pre-Filter - Card Board Type (L 600 X W 400 X Thickness 45 Mm) , C(X)Seedbank_C) Pre-Filter - Roll Type (L 620 X W 400 X Thickness 10 Mm) , C(X)Seedbank_D) Led T8 Tube, Daylight (4 Feet) , B(I) Molecular Laboratory_To Provide Labour, Materials & Test Instrument To Carry Out The Servicing Requirement For One Unit Of Fume Hood Inclusive Of Preventive Maintenance (Model - Modulap) (Once Per Year) , C(I) Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_(Model: Advance Lab & Ad04h (4Ft), Serial No.: Ad04h-00082/19)Seedbank_Airflow Velocity Test (2 Times A Year ) , C(I) Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_(Model: Advance Lab & Ad04h (4Ft), Serial No.: Ad04h-00082/19)Seedbank_Particle Count Test (1 Time A Year ) , C(Ii) Seedbank_A) Hepa Filter (L 1200 X W 600 X Thickness 66 Mm) Double Side Guard, Airflow -0.45 M/S, Efficiency 99.99% @ 0.3Um , C(Ii) Seedbank_B) Pre-Filter (L 1170 X W 500 X Thickness 10 Mm) , C(Ii)Seedbank_C) Uv Lamp (3 Feet) , C(Ii) Seedbank_D)Led T8 Tube, Daylight (4 Feet ) , C(Iii) Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_[Model: Advance Lab Ad04v, Serial No: Ad04/5119-349]_Airflow Velocity Test (2 Times A Year ) , C(Iii)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_[Model: Advance Lab Ad04v, Serial No: Ad04/5119-349]_Particle Count Test (1 Time A Year ) , C(Iv)Seedbank_A) Hepa Filter ( L 600 X W 400 X Thickness 66 Mm ) Double Side Guard, Airflow -0.45 M/S, Efficiency 99.99% @ 0.3Um , C(Iv)Seedbank_B) Pre-Filter: Card Board Type (L 595 X W 395 X Thickness 45 Mm) , C(Iv)Seedbank_C)Pre-Filter - Roll Type (L 615 X W 435 X Thickness 10 Mm) , C(Iv)Seedbank_D) Led T8 Tube, Daylight (2 Feet ) , C(V)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_ [Model: Advance Lab Ad04v, Serial No: Ad04/5119-350] _Airflow Velocity Test (2 Times A Year ) , C(V)Seedbank_[To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_ Model: Advance Lab Ad04v, Serial No: Ad04/5119-350] _Particle Count Test (1 Time A Year ) , C(Vi)Seedbank_A)Hepa Filter (L600 X W 400 X Thickness 66 Mm ) Double Side Guard, Airflow -0.45 M/S, Efficiency 99.99% @ 0.3Um , C(Vi)Seedbank_B) Pre-Filter: Card Board Type (L 595 X W 395 X Thickness 45 Mm) , C(Vi)Seedbank_C) Pre-Filter - Roll Type (L 615 X W 435 X Thickness 10 Mm) , C(Vi)Seedbank_D) Led T8 Tube, Daylight (2 Feet ) , C(Xi)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_(Model:Bbs-V1300, Serial No.: Bbs13v2101037d_Airflow Velocity Test (1 Time A Year ) , C(Xi)Seedbank_To Provide Labour, Materials & Test Instrument To Carry Out The Following Test And/Or Certification_(Model:Bbs-V1300, Serial No.: Bbs13v2101037d_- Particle Count Test (1 Time A Year ) , C(Xii)Seedbank_A) Hepa Filter (L 1200 X W 600 X Thickness 70 Mm) Double Side Guard , C(Xii)Seedbank_B) Pre-Filter (L 300 X W 1100 X Thickness 10 Mm) , C(Xii)Seedbank_C) Uv Lamp ( 3 Feet) , C(Xii)Seedbank_D) Led T8 Tube, Daylight (3 Feet) , B(V) Molecular Laboratory_To Provide Labour, Materials & Test Instrument To Carry Out The Servicing Requirement For One Unit Of Homogeniser (Model: Omni Bead Ruptor 24)
|