400Kv Gis For Powergrid Kps3 Tender Pre Bid Tie Up For Supply And Services Of 400Kv Gis And Associated Equipments For Powergrid 400Kv Gis Package (Package-Ii) At Kps 3 Tender , 1. 400Kv Gis Ac Station At Kps3 (Hvdc) Supply- Gis : 400Kv,63Ka For 1S,Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 1.1.01-1.1.12) 400Kv, 3150A, 63Ka, Single Phase,Sf6 Gas Insulated Bus Duct (Gib) Outside Gis Hall Alongwith Associated Support Structure , 420Kv, 3150 A, 63 Ka, Sf6 Gis Converter Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Tie Bay Module (Of Converter Feeder) As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Line Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Tie Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Reactor Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Transformer Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Sectionaliser Module As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Busbar Module As Per Section-Project, Technical Specification , 420Kv Gis Interface Module For Future Extension Of Bus Bar As Per Ts , 420Kv, 3150A, 63Ka Single Phase Sf6 To Air Bushing Connecting Gis To Ais Alongwith Support Structure , Local Control Cubicle (Lcc) , Supply- Gis : Special Tools And Testing & Maintenance Instruments As Per Ts (Item Sl. No: 1.2.01-1.2.03): Sf6 Gas Processing Unit , Gas Analyzer [Dew Point Meter] , Sf6 Gas Leak Detector , Spares- Gis : 400Kv,63Ka For 1S,Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 1.3.01-1.3.52): 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type With O Rings , Sf6pressuregaugecumswitch/Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets,ORingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags (3 % Of Totalweight) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas (5 % Of Total Gas Quantity) , Locking Device To Keep The Dis-Connectors (Isolators)And Earthing/Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators (Gas Through) Of Each Type (Complete Withmetal Ring Etc.) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type (Complete With Metal Ring Etc.)Along With Associated Contacts And Shields , 420Kv, 3150A, 63Ka Single Phase Sf6 To Air Bushing Of Each Type , Lcc Spares- Aux. Relays, Contactors,Push Buttons, Switches,Lamps,Annunciation Windows, Mcb, Fuses,Timers, Terminal Blocks Etc. Of Eachtype & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 4000A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Ferrules, Joints & Coupling Of Each Type For Cb , Window Slope/ Observing Glass Each Type , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. (Asapplicable) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter Each Type , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor (For Hydraulic Operated Mechanism, If Applicable) , Hydraulic Filter Of Each Type (For Hydraulic Operated Mechanism, Ifpplicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type (As Applicable) (Forhydraulic Operated Mechanism, If Applicable) , 400Kv Gis Circuit Breaker - N2 Accumulator (For Hydraulic Operatedmechanism, If Applicable) , Valves Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pipe Length (Copper & Steel) Of Each Size & Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil (5% Of Total Oil Quantity)(For Hydraulic Operated Mechanism, If Applicable) , Pressure Relief Device Of Each Type (For Hydraulic Operated Mechanism,If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. (For Spring Operated Mechanism, Ifapplicable) Of Each Type , 400Kv Gis- Single Phase Of 3150Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect (Note 1- The Contractorshall Supply Spare For Disconnectorswitch To Ensure One To One Replacementof All Disconnector Switch Supplied Asmain Equipment Without Any Requirementof Modification In Fittings At Site Tocover All Different Types Ofdisconnector Switch Supplied. In Case,Quantity Of Supplied Dis-Connectorswitch Types (For One To Onereplacement) Are More Than The Quantitymentioned In Bps For Spare, Thecontractor Shall Supply Theseadditional Types Of Disconnector Switchwithout Any Additional Priceimplication To Powergrid And Quantitiesof These Additional Type Ofdisconnector Switch Are Deem To Beincluded In The Quantities Mentioned Inbps For Spare Disconnector. Note 2 - Incase, Dis-Connector Switch (Ds) & Earthswitch (Es) Is Provided In A Sameenclosure With Common Operatingmechanism, Then The Module Comprisingof Dis-Connector & Earth Switch Insingle Enclosure With Common Operatingmechanism Is To Be Provided Under Thehead Of Spare Dis-Connector Only. Note3- In Case, Dis-Connector Switch (Ds)&Earth Switch (Es) Is Provided In Asame Enclosure With Separate Operatingmechanism, Then The Module Comprisingof Dis-Connector & Earth Switch Insingle Enclosure With Separateoperating Mechanism Is To Be Providedunder The Head Of Spare Dis-Connectoronly.) , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc.,Complete In All Respect (Note 1 - In Case, Dis-Connector Switch (Ds) &Earth Switch (Es) Is Provided In A Same Enclosure With Commonoperating Mechanism, Then The Module Comprising Of Dis-Connector &Earth Switch In Single Enclosure With Common Operating Mechanism Is Tobe Provided Under The Head Of Spare Dis-Connector Only. Note 2 - Incase, Dis-Connector Switch (Ds) & Earth Switch (Es) Is Provided In Asame Enclosure With Separate Operating Mechanism, Then The Modulecomprising Of Dis-Connector & Earth Switch In Single Enclosure Withseparate Operating Mechanism Is To Be Provided Under The Head Of Sparedis-Connector Only.) , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit,Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect (Note 1 - In Case, Dis-Connector Switch (Ds) & Earthswitch (Es) Is Provided In A Same Enclosure With Common Operatingmechanism, Then The Module Comprising Of Dis-Connector & Earth Switchin Single Enclosure With Common Operating Mechanism Is To Be Providedunder The Head Of Spare Dis-Connector Only. Note 2 - In Case,Dis-Connector Switch (Ds) & Earth Switch (Es) Is Provided In A Sameenclosure With Separate Operating Mechanism, Then The Modulecomprising Of Dis-Connector & Earth Switch In Single Enclosure Withseparate Operating Mechanism Is To Be Provided Under The Head Of Sparedis-Connector Only.) , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch (If Applicable)-400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer (3 Cores, Type-Cta)With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Of Current Transformer (2 Cores, Type-Ctb)With Associated Enclosure And Primary Conductor Complete In Allrespect , Gis Spares: 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Gis Spares: 400Kv Gis- Single Phase La With Associated Enclosure Complete In All Respect , 2. 400Kv Gis Ac Station At Kps-3 Station (Extn) Supply- Gis : 400Kv,63Ka For 1S,Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 2.1.01-2.1.08): 400Kv, 3150A, 63Ka, Single Phase,Sf6 Gas Insulated Bus Duct (Gib) Outside Gis Hall Alongwith Associated Support Structure , 420Kv, 3150 A, 63 Ka, Sf6 Gis Line Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Tie Bay Module As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Extension As Per Section-Project, Technical Specification , 400Kv, 4000A, 63Ka, Single Phase,Sf6 Gas Insulated Bus Duct (Gib) Outside Gis Hall Alongwith Associated Support Structure , 420Kv Gis Interface Module For Future Extension Of Bus Bar As Per Ts , 420Kv, 3150A, 63Ka Single Phase Sf6 To Air Bushing Connecting Gis To Ais Alongwith Support Structure , Local Control Cubicle (Lcc) , 3. 400Kv Ac Gis Extension South Olpad Supply- Gis : 400Kv,63Ka For 1S,Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 3.1.01-3.1.07): 400Kv, 3150A, 63Ka, Single Phase,Sf6 Gas Insulated Bus Duct (Gib) Outside Gis Hall Alongwith Associated Support Structure , 420Kv, 3150A, 63 Ka, Sf6 Gis Converter Feeder Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150A, 63 Ka, Sf6 Gis Tie Bay Module (Of Converter Feeder) As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Extension As Per Section-Project, Technical Specification , 420Kv Gis Interface Module For Future Extension Of Bus Bar As Per Ts , 420Kv, 3150A, 63Kasingle Phase Sf6 To Air Bushing Connecting Gis To Ais Alongwith Associated Support Structure , Local Control Cubicle (Lcc) , Supply- Gis : Special Tools And Testing & Maintenance Instruments As Per Ts (Item Sl. No. 3.2.01-3.2.03): Sf6 Gas Processing Unit , Gas Analyzer [Dew Point Meter] , Sf6 Gas Leak Detector , Spares- Gis : 400Kv,63Ka For 1S,Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 3.3.01-3.3.52): 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type With O Rings , Sf6pressuregaugecumswitch/Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets,ORingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags (3 % Of Totalweight) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas (5 % Of Total Gas Quantity) , Locking Device To Keep The Dis-Connectors (Isolators)And Earthing/Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators (Gas Through) Of Each Type (Complete Withmetal Ring Etc.) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type (Complete With Metal Ring Etc.)Along With Associated Contacts And Shields , 420Kv, 3150A, 63Ka Single Phase Sf6 To Air Bushing Of Each Type , Lcc Spares- Aux. Relays, Contactors,Push Buttons, Switches,Lamps,Annunciation Windows, Mcb, Fuses,Timers, Terminal Blocks Etc. Of Eachtype & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 4000A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Ferrules, Joints & Coupling Of Each Type For Cb , Window Slope/ Observing Glass Each Type , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. (Asapplicable) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter Each Type , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor (For Hydraulic Operated Mechanism, If Applicable) , Hydraulic Filter Of Each Type (For Hydraulic Operated Mechanism, Ifpplicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type (As Applicable) (Forhydraulic Operated Mechanism, If Applicable) , 400Kv Gis Circuit Breaker - N2 Accumulator (For Hydraulic Operatedmechanism, If Applicable) , Valves Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pipe Length (Copper & Steel) Of Each Size & Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil (5% Of Total Oil Quantity)(For Hydraulic Operated Mechanism, If Applicable) , Pressure Relief Device Of Each Type (For Hydraulic Operated Mechanism,If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. (For Spring Operated Mechanism, Ifapplicable) Of Each Type , 400Kv Gis- Single Phase Of 3150Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect (Note 1- The Contractorshall Supply Spare For Disconnectorswitch To Ensure One To One Replacementof All Disconnector Switch Supplied Asmain Equipment Without Any Requirementof Modification In Fittings At Site Tocover All Different Types Ofdisconnector Switch Supplied. In Case,Quantity Of Supplied Dis-Connectorswitch Types (For One To Onereplacement) Are More Than The Quantitymentioned In Bps For Spare, Thecontractor Shall Supply Theseadditional Types Of Disconnector Switchwithout Any Additional Priceimplication To Powergrid And Quantitiesof These Additional Type Ofdisconnector Switch Are Deem To Beincluded In The Quantities Mentioned Inbps For Spare Disconnector. Note 2 - Incase, Dis-Connector Switch (Ds) & Earthswitch (Es) Is Provided In A Sameenclosure With Common Operatingmechanism, Then The Module Comprisingof Dis-Connector & Earth Switch Insingle Enclosure With Common Operatingmechanism Is To Be Provided Under Thehead Of Spare Dis-Connector Only. Note3- In Case, Dis-Connector Switch (Ds)&Earth Switch (Es) Is Provided In Asame Enclosure With Separate Operatingmechanism, Then The Module Comprisingof Dis-Connector & Earth Switch Insingle Enclosure With Separateoperating Mechanism Is To Be Providedunder The Head Of Spare Dis-Connectoronly.) , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc.,Complete In All Respect (Note 1 - In Case, Dis-Connector Switch (Ds) &Earth Switch (Es) Is Provided In A Same Enclosure With Commonoperating Mechanism, Then The Module Comprising Of Dis-Connector &Earth Switch In Single Enclosure With Common Operating Mechanism Is Tobe Provided Under The Head Of Spare Dis-Connector Only. Note 2 - Incase, Dis-Connector Switch (Ds) & Earth Switch (Es) Is Provided In Asame Enclosure With Separate Operating Mechanism, Then The Modulecomprising Of Dis-Connector & Earth Switch In Single Enclosure Withseparate Operating Mechanism Is To Be Provided Under The Head Of Sparedis-Connector Only.) , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit,Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect (Note 1 - In Case, Dis-Connector Switch (Ds) & Earthswitch (Es) Is Provided In A Same Enclosure With Common Operatingmechanism, Then The Module Comprising Of Dis-Connector & Earth Switchin Single Enclosure With Common Operating Mechanism Is To Be Providedunder The Head Of Spare Dis-Connector Only. Note 2 - In Case,Dis-Connector Switch (Ds) & Earth Switch (Es) Is Provided In A Sameenclosure With Separate Operating Mechanism, Then The Modulecomprising Of Dis-Connector & Earth Switch In Single Enclosure Withseparate Operating Mechanism Is To Be Provided Under The Head Of Sparedis-Connector Only.) , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch (If Applicable)-400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer (3 Cores, Type-Cta)With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Of Current Transformer (2 Cores, Type-Ctb)With Associated Enclosure And Primary Conductor Complete In Allrespect , Gis Spares: 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Gis Spares: 400Kv Gis- Single Phase La With Associated Enclosure Complete In All Respect , Spares- Gis : Reference Unit Price For Addition / Deletion Of Supply Items (Unit Prices Of Individual Equipment Included Here Or In Manadatory Spares Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Bidder To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (Item Sl. No. 4.01-4.05): Spares: 400Kv Gis- Gis Metallic Enclosure , Spares: 400Kv Gis- Expansion Bellows/ Joints , Spares: 400Kv Gis- Tee Bend , Spares: 400Kv Gis- L Bend , Spares: Controlled Switching Device For 420 Kv, 3-Ph Circuit Breaker , 400Kv Gis Ac Station At Kps3 (Hvdc) Services- Gis : 400Kv, 63Ka For Is, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 5.01-5.10): Services- 400Kv Gis: Supervision Of Erection Of Gis , Services- 400Kv Gis:Supervision Of Erection Of Gas Insulated Bus Duct , Services- 400Kv Gis:Supervision Of Erection Of Sf6 To Air Bushing , Services- 400Kv Gis:Testing & Commissioning Of Gis , Services- 400Kv Gis : Testing & Commissioning Of Gas Insulated Bus Duct , Services- 400Kv Gis : Testing & Commissioning Of Sf6 To Air Bushing , Services- 400Kv Gis : Final Successful Hv/ Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- 400Kv Gis : Insulation Co-Ordination Studies For Gis System , Services- 400Kv Gis : Training For Gis At Site , Services- 400Kv Gis : Training For Gis At Manufacturer Works , 400Kv Gis Ac Station At Kps-3 Station (Extn) Services- Gis : 400Kv, 63Ka For Is, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 6.01-6.10): Services- 400Kv Gis: Supervision Of Erection Of Gis , Services- 400Kv Gis:Supervision Of Erection Of Gas Insulated Bus Duct , Services- 400Kv Gis:Supervision Of Erection Of Sf6 To Air Bushing , Services- 400Kv Gis:Testing & Commissioning Of Gis , Services- 400Kv Gis : Testing & Commissioning Of Gas Insulated Bus Duct , Services- 400Kv Gis : Testing & Commissioning Of Sf6 To Air Bushing , Services- 400Kv Gis : Final Successful Hv/ Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- 400Kv Gis : Insulation Co-Ordination Studies For Gis System , Services- 400Kv Gis : Training For Gis At Site , Services- 400Kv Gis : Training For Gis At Manufacturer Works , 400Kv Ac Gis Extension South Olpad Services- Gis : 400Kv, 63Ka For Is, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 7.01-7.10): Services- 400Kv Gis: Supervision Of Erection Of Gis , Services- 400Kv Gis:Supervision Of Erection Of Gas Insulated Bus Duct , Services- 400Kv Gis:Supervision Of Erection Of Sf6 To Air Bushing , Services- 400Kv Gis:Testing & Commissioning Of Gis , Services- 400Kv Gis : Testing & Commissioning Of Gas Insulated Bus Duct , Services- 400Kv Gis : Testing & Commissioning Of Sf6 To Air Bushing , Services- 400Kv Gis : Final Successful Hv/ Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- 400Kv Gis : Insulation Co-Ordination Studies For Gis System , Services- 400Kv Gis : Training For Gis At Site , Services- 400Kv Gis : Training For Gis At Manufacturer Works , Services- Gis : Reference Unit Price For Addition / Deletion Of Services: (Unit Prices Of Individual Services Included Here Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Vendor To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (Item Sl. No. 8.01-8.05): Services- 400Kv Gis: Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Supervision Of Erection Of Gis , Services- 400Kv Gis: Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Testing & Commissioning Of Gis , Services- 400Kv Gis: Demobilization And Remobilization Charges For Gis Erection Supervision Team , Services- 400Kv Gis: Demobilization And Remobilization Charges For Gistesting & Commissioning Team , Services- 400Kv Gis: Demobilization & Remobilization Charges Ofhv Test Kit Along With Operator
|